• Title/Summary/Keyword: Single index

Search Result 1,565, Processing Time 0.028 seconds

Development & Evaluation of Real-time Ensemble Drought Prediction System (실시간 앙상블 가뭄전망정보 생산 체계 구축 및 평가)

  • Bae, Deg-Hyo;Ahn, Joong-Bae;Kim, Hyun-Kyung;Kim, Heon-Ae;Son, Kyung-Hwan;Cho, Se-Ra;Jung, Ui-Seok
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.113-121
    • /
    • 2013
  • The objective of this study is to develop and evaluate the system to produce the real-time ensemble drought prediction data. Ensemble drought prediction consists of 3 processes (meteorological outlook using the multi-initial conditions, hydrological analysis and drought index calculation) therefore, more processing time and data is required than that of single member. For ensemble drought prediction, data process time is optimized and hardware of existing system is upgraded. Ensemble drought data is estimated for year 2012 and to evaluate the accuracy of drought prediction data by using ROC (Relative Operating Characteristics) analysis. We obtained 5 ensembles as optimal number and predicted drought condition for every tenth day i.e. 5th, 15th and 25th of each month. The drought indices used are SPI (Standard Precipitation Index), SRI (Standard Runoff Index), SSI (Standard Soil moisture Index). Drought conditions were determined based on results obtained for each ensemble member. Overall the results showed higher accuracy using ensemble members as compared to single. The ROC score of SRI and SSI showed significant improvement in drought period however SPI was higher in the demise period. The proposed ensemble drought prediction system can be contributed to drought forecasting techniques in Korea.

Analysis of Process Capability Index for Multiple Measurements (다측정 공정능력지수의 특성분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.91-97
    • /
    • 2016
  • This study is concerned about the process capability index in single process. Previous process capability indices have been developed for the consistency with the nonconforming rate due to the process target value and skewness. These indices calculate the process capability by measuring one spot in an item. But the only one datum in an item reduces the representativeness of the item. In addition to the lack of representativeness, there are many cases that the uniformity of the item such as flatness of panel is absolutely important. In these cases, we have to measure several spots in an item. Also the nonconforming judgment to an item is mainly due to the range not due to the standard variation or the shift from the specifications. To imply the uniformity concept to the process capability index, we should consider only the variation in an item. It is the within subgroup variation. When the universe is composed of several subgroups, the sample standard deviation is the sum of the within subgroup variation and the between subgroup variation. So the range R which represents only the within subgroup variation is the much better measure than that of the sample standard deviation. In general, a subgroup contains a couple of individual items. But in our cases, a subgroup is an item and R is the difference between the maximum and the minimum among the measured data in an item. Even though our object is a single process index, causing by the subgroups, its analytic structure looks like a system process capability index. In this paper we propose a new process capability index considering the representativeness and uniformity.

A Study On The Realization Of Multi-Threshold Function By Partition Of Switching Functions (스윗칭함수 분할에 의한 다역치함수 실현에 관한 연구)

  • Chae Tak Lim
    • 전기의세계
    • /
    • v.23 no.4
    • /
    • pp.53-59
    • /
    • 1974
  • This paper investigates the theoretical properties of a logic element called the multithreshold threshold element, which is a generalization of the single-threshold threshold element. The primary partition os a systematic method of obtaining the multi-threshold realization of a switching function by the index numbers. The concept of comparable vertices of the same index numbers introduced in this paper is very promising for testing the multi-threshold partition by the initial condition to be defined by the minterms of the same index numbers.

  • PDF

Design of Double-clad, Dispersion-Compensated Fiber at$\lambda=1.55\mu\textrm{m}$ : Step & Triangular Index Profile ($\lambda=1.55\mu\textrm{m}$에서 계단형, 삼각형 분포-이중클래드 분산보상 광섬유의 설계)

  • 김수아;김창민
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.54-63
    • /
    • 1997
  • The 1-D finite-element mehtod is applied for designing double-clad otpical fibers with dispersion-compensation capability. design parameters allowing only a $LP_{01}$ single mode are treated and macro-bending loss are taken into consideration. Design parameters are extracted to have the compensation ratio $(L_{SMF}/L_{DCF})$ of 6.2 for core structure with step-index profile, and of 5.2 for core with triangular-index profile.

  • PDF

Improved methods for assessing single paper's citation impact (단일 문헌의 인용 영향력 측정 방식의 개선)

  • Lee, Jae Yun
    • Proceedings of the Korean Society for Information Management Conference
    • /
    • 2011.08a
    • /
    • pp.29-34
    • /
    • 2011
  • 최근 인용 네트워크 분석을 통해서 단일 문헌의 인용 영향력을 측정하려는 시도가 다양하게 전개되고 있다. 널리 알려진 PageRank를 보완하려는 일부 시도와 함께 h-index를 단일 문헌의 인용 영향력 측정에 적용한 단일문헌 h-index도 제안되었다. 이 연구에서는 Web of Science에서 검색한 계량정보학 분야 문헌집합을 대상으로 여러 측정 방식의 특징을 비교해본 후, 새로운 인용지수 2종을 제안하였다. 제안한 인용지수는 PageRank처럼 전역 네트워크 분석 방식인 지수 1종과 h-index처럼 지역 네트워크 분석 방식인 지수 1종으로서 상황에 따라 선택하여 사용할 수 있다.

  • PDF

The Process Capability Index of Minimum Base on the Multiple Measuring Locations (다수 위치 측정에서 최소 기준에 의한 공정능력지수)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.114-119
    • /
    • 2011
  • Process capability indices (PCls) have been widely used in manufacturing industries to provide a quantitative measure of process potential and performance. The previous studies have measured only one location on each part in the case of single variate. To calculate the reliable process capability, a couple of measuring locations on each part are required. In this paper, we propose a new system process capability index $SC_{pm}$ (m) which is the minimum value of the location PCls.

An Anatomic Study of the Extensor Tendons of the Human Hand (수배부의 신전건에 대한 해부학적 연구)

  • Kang, Moon-Seok;Jung, Sung-Gyun;Nam, Seoung-Min;Shin, Ho-Seong;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.836-844
    • /
    • 2011
  • Purpose: Hands are the chief organs for physically manipulating the environment, using anywhere from the roughest motor skills to the finest, and since the fingertips contain some of the densest areas of nerve endings on the human body, they are continuously used organ with complex functions, and therefore, often gets injured. To prevent any functional loss, a detailed anatomical knowledge is required to have a perfect surgical treatment. Also it is necessary to have a thorough understanding of arrangements of the human extensor tendons and intertendinous connections when tenoplasty or tendon transfer is required. We performed a study of the arrangements of the human extensor tendons and the configuration of the intertendinous connections over the dorsum of the wrist and hand. Methods: A total of 58 hands from Korean cadavers were dissected. The arrangements of extensor indicis proprius, extensor digitorum communis, and extensor digiti minimi tendons and intertendinous connections were studied. Results: The most common distribution patterns of the extensor tendons of the fingers were as follows: a single extensor indicis proprius (EIP) tendon which inserted ulnar to the extensor digitorum-index (EDC-index); a single EDC-index; a single EDC-middle; a double EDC-ring; an absent EDC-little; a double extensor digiti minimi (EDM), a single EDC-index (98.3%), a single EDC-middle (62%), a double EDC-ring (50%), and an absent (65.5%) or a single (32.8%) EDC-little. A double (70.6%) EDM tendons were seen. Intertendinous connections were classified into 3 types: type 1 with thin filamentous type, type 2 with a thick filamentous type, and type 3 with a tendinous type subdivided to r shaped 3r type and y shaped 3y type. The most common patterns were type 1 in the 2nd intermetacarpal space, type 2 in the 3rd intermetacarpal space, and type 3r in the 4th intermetacarpal space. And in the present study, we observed one case of the extensor digitorum brevis manus (EDBM) on the boht side. Conclusion: A knowledge of both the usual and possible variations of the extensor tendon and the intertendinous connection is useful in the identification and repair of these structures.

The plaque-removing efficacy of a single-tufted brush on the lingual and buccal surfaces of the molars

  • Lee, Dong-Won;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.3
    • /
    • pp.131-134
    • /
    • 2011
  • Purpose: To test the plaque-removal efficacy of a single-tufted toothbrush on the posterior molars compared with a flat-trimmed toothbrush. Methods: Forty-nine subjects were selected. Professional instruction and written brushing instructions were given. After thorough supra-gingival scaling and polishing, all subjects were asked to abstain from oral hygiene procedures for 24 hours prior to the first experiment. The subjects were randomized to a treatment sequence. The modified Quigley and Hein plaque index was recorded pre- and post-tooth brushing, at 6 surfaces of the posterior molars. After a wash-out period, all the remaining plaque was removed professionally. Twenty-four hours of brushing abstinence was again performed. The plaque index was recorded pre- and post-tooth brushing after the subjects were given the second toothbrush in the cross-over sequence. Results: The percentage reductions in plaque scores achieved with the single-tufted brushes were significantly higher than those of the flat-trimmed brush at the maxillary buccal interproximal, marginal and mandibular lingual interproximal site. The other locations showed no significant difference. Conclusions: The results of the present study implied that the single-tufted brush could be an effective tool for the removal of plaque at some, but not all, sites of the posterior molars.

A Comparison of the Goodness-of-Fit between Two Models of Expenditure Function: a Single-Equation Model versus a Complete- System-of-Demand-Equation Model (단일방정식과 관련방정식체계를 적용한 소비지출 함수의 모델 적합성 비교)

  • 황덕순;김숙향
    • Journal of Families and Better Life
    • /
    • v.20 no.1
    • /
    • pp.45-56
    • /
    • 2002
  • The main purposes of this article are to introduce the theoretical backgrounds and empirical application methods of two different Models for the function of expenditure, and to compare the goodness-o(-fit of the two models: a single-equation model and a complete-system-of-demand-equation model. For the empirical analysis of the single-equation model, a linear formula and a double-leg formula were employed. In order to test the complete-system-of-demand-equation model empirically, the \"Linear Approximation/Almost Ideal Demand System (LA/AIDS)" was used. The independent variables were the total living expense and expenditure categories Price index. The data used in this study were obtained from the quarterly statistics of "The Annual Report on the Urban Family Income and Expenditure Survey (Dosigagyeyonbo)" and "The Annual Report on the Consumer Price Index (Sobijamulgajaryo)," for the years 1994 to 1997. The goodness-of-fit (R-square) was higher with the complete-system-of-demand-equation model than with the single-equation model for the budget share on food (excluding eating-out expenses) and for the share on cultural and recreational activities. However, there was no difference between the two models in terms of the proportion of the expenditure on automobile fuel.fuel.

A study on the removal of mixed heavy metal ions using crab shell (게 껍질을 이용한 수중의 복합 중금속 제거에 관한 연구)

  • Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.729-735
    • /
    • 2002
  • In order to examine the inhibition effect of other heavy metal ions on the removal of heavy metal ions by crab shell in aqueous solution, 10 heavy metal ions $(Cr^{3+},\;Cd^{2+},\;Ni^{2+},\;Zn^{2+},\;Hg^{2+},\;Cu^{2+},\;Mn^{2+],\;Fe^{2+},\;Fe^{3+},\;Pb^{2+})$ were used as single heavy metal ions and mixed heavy metal ions, respectively. In single heavy metal ions, $Pb^{2+},\;Cr^{3+},\;Cu^{2+}$ were well removed by crab shell, however, $Cd^{2+},\;Ni^{2+},\;Zn^{2+},\;Mn^{2+}$ were not. The heavy metal removal increased as the increase of covalent index (Xm$^2$r), and the relationship classified heavy metal ions as 2 heavy metal groups $(Fe^{3+},\;Fe^{2+},\;Cu^{2+},\; Cr^{3+},\;Mn^{2+},\;Ni^{2+},\;Zn^{2+}\;group\;and\;Pb^{2+},\;Hg^{2+},\;Cd^{2+}\;group)$. In mixed heavy metal ions, the removals of $Fe^{2+},\;Fe^{3+},\;Pb^{2+},\;Cu^{2+}$ as 0.49 m㏖/g, regardless of the existence of other heavy metal ions, were similar to the result of single heavy metal ions experiment. The removals of $Mn^{2+},\;Cd^{2+},\;Ni^{2+}$ decreased as the existence of other heavy metal ions, however, the removal of $Zn^{2+},\;Cr^{3+},\;Hg^{2+}$ increased.