• Title/Summary/Keyword: Single crown

Search Result 228, Processing Time 0.028 seconds

Alterations of the soft tissue dimensions around implant-supported singletooth replacements in the maxillary anterior region - A retrospective longitudinal study - (상악 전치부 임플란트지지 수복금관의 주변 연조직 제원 변화에 관한 누년적 연구)

  • Chang, Moon-taek
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.507-517
    • /
    • 1998
  • This study was performed to investigate the soft tissue changes around single implant-supported crowns during followup periods. Twenty patients(31 implants) whose single missing tooth in the maxillary anterior region had been replaced with an single implant-supported crown were recruited for the study. Crown length, soft tissue level and papilla height at the single implant-supported crowns were measured at follow-up examination and calculated from the slides taken at time of crown placement. as well Papilla index was scored from the slides taken at the time of crown placement and follow-up examination. A very little amount of recession occurred and the soft tissue level moved more apically and the papilla height increased significantly (p<0.01). Especially, both mesial and distal papilla index at single implant-supported crowns increased significantly during follow-up periods (p<0.001). When the two slides taken at the time of crown placement and follow-up were compared simultaneously, except one site, papillae size increased at all sites. From the results of the study, the interdental papillae at the single implant-supported crowns seemed to regenerate significantly and their crown margins were stable during follow-up periods. Hence it is indicated that various surgical interventions at on early stage to enhance soft tissue esthetics arourd single implants may be unnecessary.

  • PDF

Soft tissue reactions around implant-supported single-tooth replacements in the maxillary anterior region (상악 전치부 단일 임플란트 지지 수복금관의 주변 연조직반응의 단면적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.321-337
    • /
    • 1998
  • The aims of this study were firstly to investigate soft tissue reactions around single implant-supported crowns and secondly to compare soft tissue dimensions and conditions of the crowns in relation to interdental papillae, and lastly to investigate patients'esthetic satisfaction with their single implant-supported crowns according to the interdental papillae presence/absence. Twenty-nine patients (41 implants) whose single missing tooth in the maxillary anterior region had been replaced by single implant-supported crown participated for the study and various variables of soft tissue conditions, dimensions and crown dimensions were measured around the single implant-supported crowns at clinical examination and from study models and slides. The results showed that the soft tissue conditions around the single implantsupported crowns were similar to those around implants used for partially or totolly edentulous patients. Except for the high frequency of bleeding on probing, all other parameters revealed healthy conditions. The buccal sites of the crown had a shallow pocket comparing with other sites. At all sites of the crown, similar status of little inflammation was found. Mesial sites and central-incisor positioned implantsupported crowns had lower contact point position than distal sites and lateral-incisor positioned crowns, respectively. Mucositis index, probing depth and contact point position were significantly correlated with papillae index(p < 0.05). More inflammation and lower contact point position were found at the implant-supported crown with no interdental space than that with interdental space. Patients showed high esthetic satisfaction regardless of interdental space presence. The result indicated that, despite of their submucosal crown margins, single implantsupported crowns have soft tissue conditions as good as other implants used for the treatment of the different types of edentulism and a clinician can manipulate interdental papilla height by modifying crown shapes within the limits of not violating total esthetics.

  • PDF

Wave Screening Performance of the Submerged Breakwater With Various Crown Widths (폭 변화에 따른 잠제의 파랑 차단 성능)

  • Cho Won Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.4
    • /
    • pp.206-212
    • /
    • 2004
  • The numerical analysis on the wave screening performance of the submerged breakwater with various crown widths is presented. The fluid motion is considered as linearized two dimensional potential flow and the finite element method is used to analyze the wave screening performance of the submerged breakwater. It is found that single-submerged breakwater with large crown width shows the most effective wave screening performance and single-submerged breakwater with small crown width also shows fairly good wave screening performance but its effectiveness is less than that of single-submerged breakwater with large crown width. However, double- or triple-submerged breakwater with small crown width shows more effective wave screening performance than that of single- or double-submerged breakwater with large crown width. It is expected that the submerged breakwater with small crown width is economical because it reduces the size of structure.

ESTIMATING CROWN PARAMETERS FROM SPACEBORNE HIGH RESOLUTION IMAGERY

  • Kim, Choen;Hong, Sung-Hoo
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.247-249
    • /
    • 2007
  • Crown parameters are important roles in tree species identification, because the canopy is the aggregate of all the crowns. However, crown measurements with spaceborne image data have remained more difficult than on aerial photographs since trees show more structural detail at higher resolutions. This recognized problem led to the initiation of the research to determine if high resolution satellite image data could be used to identify and classify single tree species. In this paper, shape parameters derived from pixel-based crown area measurements and texture features derived from GLCM parameters in QuickBird image were tested and compared for individual tree species identification. As expected, initial studies have shown that the crown parameters and the canopy texture parameters provided a differentiating method between coniferous trees and broad-leaved trees within the compartment(less than forest stand) for single extraction from spaceborne high resolution image.

  • PDF

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

MARGINAL FIT OF THE AURO GALVANO CROWN SYSTEM MADE USING THE ELECTROFORMING TECHNIQUE

  • Yang Jae-Ho;Song Tae-Jin;Han Jung-Suk;Lee Jae-Bong;Lee Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.679-684
    • /
    • 2004
  • Statement of problem. There have been few studies about the marginal fit of Auro Galvano Crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations. Material and methods. The in vitro marginal discrepancies of metal-ceramic, Auro Galvano Crown and coping were evaluated and compared. The Auro Gavano Crowns were made from one extracted maxillary central incisor prepared by milling machine. 30crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. Mean marginal gap dimensions and standard deviations at the marginal opening for the anterior single crowns were $74{\pm}21{\mu}m$ for the control (metal-ceramic restoration), $45{\pm}11{\mu}m$ for Auro Galvano Crown coping, and $51{\pm}9{\mu}m$ for the Auro Galvano Crown. Conclusions. Auro Calvano Crown showed significantly smaller (P<.05) marginal gap than the control. Ceramic application did not significantly affected the marginal fit of Auro Galvano Crown. (P>.05)

TROPICAL TREE MORPHOLOGY USING AIRBORNE LIDAR DATA

  • JANG, Jae-Dong;Yoon, Hong-Joo
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.676-679
    • /
    • 2006
  • Mangrove crowns were delineated using active sensor LIDAR (LIght Detection And Ranging) data by a crown delineating model developed in this study. LIDAR data were acquired from airborne survey by a helicopter for the estuary of Macouria in the northeast coast of French Guiana. The canopy height image was derived from LIDAR vector data by calculating the difference between ground and non-ground data. The mangrove site in the study area was classified to three sectors by the time of mangrove settlement; Mangrove 1986, 2002 and 2003. The estimated crown of Mangrove 1986 was reliable defined for their size, number and volume because of larger crown size and bigger variation of crown height. The tree crown size of Mangrove 2002 and 2003 by the model was overestimated and the number of trees was much underestimated. The estimated crown was not for single crown but a crown group due to homogenous crown height and spatial resolution of LIDAR data. However the canopy height image derived from LIDAR data provided three-dimensional information of mangroves.

  • PDF

A CASE REPORT ON PRIMARY INCISOR TREATMENT USING OPEN-FACE STAINLESS STEEL CROWN (Open-face Stainless Steel Crown을 이용한 유전치의 치료에 대한 증례보고)

  • Kim, Jong-Min;Choi, Hyung-Jun;Lee, Jae-Ho;Choi, Byung-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.781-787
    • /
    • 1997
  • In spite of the improvements of the techniques in the field of preventive dentistry, many children still present with extensive destruction of primary anterior teeth. Not only the practioner must consider the pulp state of the primary incisor, but also restore the form, function and esthetics of the tooth. Restorative treatment of primary incisor tooth requires durability, retention and esthetics. Stainless steel crowns used in restoring primary anterior teeth is retentive and durable in comparison with the composite resin, celluloid crown. But they are not esthetic. To enhance the esthetics of the anterior stainless steel crown without reducing its superior retention, an open-face stainless steel crown has been suggested. Several authors have suggested cutting away the labial portion of the stainless steel crown and placing the composite resin in that area. By following this technique, the practioner can prepare a retentive, durable, and esthetic restoration for primary teeth which have suffered from extensive loss of teeth structure. In addition, the single missing primary anterior teeth can be successfully restored by soldering the stainless steel crown together. Open-face stainless steel crown is indicated in the areas of large interproximal lesions involving incisal edge, crown fracture with pulp exposure and congenital malformation of the teeth. By this technique, the practioner can restore primary anterior teeth successfully regardless of the amount of remaining tooth structure, bruxism habit and presence of attrition. In this case, rampant caries with extensive loss of tooth structure and single missing of primary anterior tooth hart been successfully treated with open-face stainless steel crown.

  • PDF

SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT (콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례)

  • Kim, Rae-Gyoung;Song, Eon-Hee;Choi, Byeong-Gap;Kim, Hyoun-Chull;Ahn, Hyun-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF