• Title/Summary/Keyword: Single cell Performance

Search Result 488, Processing Time 0.033 seconds

Effects of electrode fabrication conditions on performance characteristics of phosphoric acid fuel cell (인산형 연료전지 성능 특성에 미치는 전극 제조 조건의 영향)

  • 송락현;김창수;신동렬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.224-229
    • /
    • 1996
  • Performance characteristics of single cell in phosphoric acid fuel cell were studied for various electrode fabrication parameters such as teflon content, electrode structure, thickness of electrocatalyst layer, platinum content and electrode area. The performance of single cell was decided from the measured voltage-current through a load change. The electrode of 40wt.% teflon exhibited high initial performance of single cell, but in the long term operation, the cell performance of 45 wt.% teflon was better. Also the single cell appeared good performance in case of electrodes with duplicate structure, thin electrocatalyst in thickness, more platinum content, and small area. These results of cell performance were discussed as related to the electrolyte flooding, formation of 3 phase boundary area, internal resistance of electrode, and microstructure of electrode.

  • PDF

Performance Characteristics of Porous Plate Single Cell For PAFC (다공성 바이폴라 사용 단위전지 성능 특성)

  • Kim, Chang-Soo;Chun, Young-Gab;Song, Rak-Hyun;Choi, Byung-Woo;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1707-1709
    • /
    • 1996
  • For the improvement of the performance and life time of phosphoric acid fuel cell, the management of electrolyte in the electrocatalyst layer and electrolyte matrix in the cell structure is very important. Porous bipolar pinto structure, that is known as an advanced type, is generally used for the storage of electrolyte in the cell. In this paper, the single cell was made of the electrode by coating directly electrocatalyst layer on porous bipolar plate. The single cell showed $186\;mA/cm^2$ at 0.6V. This performance is similar to the performance of the conventional nonporous plate single cell. The technology of porous plate single cell could be directly used to the fabrication of stack in order to improve the performance and life time of phosphoric acid fuel cell.

  • PDF

A Study on Performance of Polymer Electrolyte Membrane Fuel Cell Using Metal Foam (Metal foam을 사용한 고분자 전해질 연료전지 성능 연구)

  • KIM, MYO-EUN;KIM, CHANG-SOO;SOHN, YOUNG-JUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.554-559
    • /
    • 2015
  • Single cell of PEMFC (polymer electrolyte membrane fuel cell) is composed of bipolar plates, gasket, GDL and the MEA. Bipolar plate's function is the collecting electricity, helping oxygen/hydrogen gas diffuse evenly and draining the water and heat. In this work, we have conducted experiments to low contact resistance and improve the performance of a $25cm^2$ single cell by using metal forms. We have following experimental cases: 1) Conventional graphite serpentine channel bipolar plate; 2) Channel-less bipolar plate with nickel(Ni) based metal foam which coated by various materials. We focused the difference in contact resistance and performance of the single cell with metal foam depending on various coating materials. The experimental results show the similar performance of single cells between with serpentine channel bipolar plates and with channel-less bipolar plate using metal foams. In addition, single cell with metal foam shows potential to higher performance than conventional channel.

Performance Evaluation of Platinum Dispersed Self-humidifying Polymer Electrolyte Membrane Prepared by Using RF Magnetron Sputter

  • Kwak, Sang-Hee;Yang, Tae-Hyun;Kim, Chang-Soo;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.2
    • /
    • pp.118-122
    • /
    • 2003
  • The performance evaluation on Pt loading in the self-humidifying polymer electrolyte membrane for Polymer Electrolyte Mem-Brane Fuel Cell(PEMFC) was investigated by using single cell test and measurement of membrane resistance. The self-humidifying membrane comprised two membranes made of perfluorosulfonylfluroride copolymer resin and fine Pt particles tying between them, coated by sputtering. From the results of performance characteristics of self-humidifying membrane cell with different Pt loading, a single cell using self-humidifying membrane with 0.15 mg/$\textrm{cm}^2$ Pt loading showed better performance than that with the others over entire current density. Also, a single cell with 0.15 mg/$\textrm{cm}^2$ Pt loading had a lower resistance value than the other cells under externally nonhumidifying condition. It is indicated that the water produced in the membrane cell with 0.15 mg/$\textrm{cm}^2$ Pt loading showed a higher provision to maintain ionic conductivity of the membrane than the other cells. The optimum amount of Pt particles embedded in the membrane for self-humidifying PEMFC was determined to be about 0.15 mg/$\textrm{cm}^2$.

A Study on the Performance of the Polymer Electrolyte Membrane Fuel Cell Using the Metal Bipolar Plates (금속분리판을 이용한 고분자전해질 연료전지의 성능에 관한 연구)

  • Jeon, U.-S.;Cho, E.A.;Ha, H.-Y.;Hong, S.-A.;Oh, I.-H.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.4
    • /
    • pp.313-320
    • /
    • 2002
  • The characteristics of the AISI bipolar plates have been investigated to replace the expensive graphite bipolar plates. It was found from the contact resistance evaluation of graphites, composites, and AISI that the contact resistance of AISI was the lowest, but it could approach to that of composites at higher compression forces. The single cell operation using the AISI bipolar plates revealed that the lower performance of the AISI single cell compared to the graphite one was due to not only the higher contact resistance but the flooding effect caused by high wettability of AISI. The performance of the AISI single cell could be improved if the channels were modified appropriately. The large size AISI single cell was operated to investigated the size effect on the performance.

A study of Polarization Modulator to Single-cell type in Polarized Glasses 3D Display System Using Binocular Parallax

  • Kong, Kyung-Bae;Kwon, Jung-Jang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.71-78
    • /
    • 2019
  • Most 3D displays that are currently in the market adopt the binocular disparity method creating a different image for the left and right eye for a 3 dimensional effect. However, commercialized 3D image output devices lack in performance making it uncomfortable for the viewer and restrict the viewer to certain positions. In this paper, we propose a single-cell polarized lens type stereoscopic system which has a smaller viewing angle and reduced crosstalk, with improved light penetration compared to existing double-cell structures; and analyzed the single-cell polarized lens type stereoscopic system properties, and conducted an effect analysis of performance improvement compared to the dual-cell type. Results showed that the single-cell type had a 25% improved performance, and the 3D crosstalk index which is an important index for quality characteristics of stereoscopic systems, increased over about 37%, compared to the dual-cell type.

Performance of Single Cells with Anode Functional Layer for SOFC

  • Choi, Jin-Hyeok;Lee, Tae-Hee;Park, Tae-Sung;Yoo, Young-Sung
    • New & Renewable Energy
    • /
    • v.5 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • To improve the performance of the anode-supported Solid Oxide Fuel Cell (SOFC) which can be operated at an intermediate temperature, the functional layer (FL) is introduced on a anode substrate. And the scandia-stabilized zirconia (ScSZ) and samaria-doped ceria (SDC) which have higher ionic conductivity and better chemical stability than yttria-stabilized zirconia (YSZ) are used as material for the anode FL with the Ni, The fabrication process of anode-supported single cell with the anode FL was established and the power density of those was evaluated. As a result, the sample with anode FL (Ni-YSZ) has higher power density than normal cell. The single cell which was composed of the FL (Ni-YSZ) and electrolyte (YSZ) showed about $550mW/cm^2$ of the maximum power density at $650^{\circ}C$ and $1430mW/cm^2$ at $750^{\circ}C$ respectively, In case of the single cell using the ScSZ and SDC as anode FL, the performance of samples decreased rapidly and those showed unstable voltage during long-term test. In case of using methane as a fuel, the cell performance with each FL decreased comparing with $H_2$ fuel. In the region of a high current density, there are large concentration polarizations.

  • PDF

Performance of Large Electrode Single Cell for Proton-Exchange-Membrane Fuel Cells (고체고분자 연료전지용 대면적 단위전지의 특성)

  • Chun, Y.G.;Kim, C.S.;Peck, D.H.;Jung, D.H.;Shin, D.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1255-1257
    • /
    • 1997
  • In order to obtain key technologies for a kW class internal humidifying proton-exchange-membrane fuel cell (PEMFC) a single cell with a large electrode area has been designed and manufactured and the performance of large area membrane/electrode assemblies (MEAs) has been evaluated by using the single cell. A small area MEA made of commercial E-TEK electrode and Nafion 117 membrane showed a performance of 0.7V, $300mA/cm^2$ whereas large area MEA made of catalyst layer on carbon support and Nafion 117 showed a lower performance. To improve the performance of large MEA direct coating of catalyst was carried out on the membrane using a screen printer.

  • PDF

Single Cell Stacked Planar Type SOFC Assembled Using a Ag-Current Collector (Ag 집전체를 적용한 평판형 SOFC 단전지)

  • Cho, Nam-Ung;Hwang, Soon-Cheol;Lee, In-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.12
    • /
    • pp.720-726
    • /
    • 2007
  • Current collectors of SOFC play a significant role on the performance of power generation. In this study a single cell stacked SOFC was assembled using Ag-mesh as a cathode current collector, and evaluated its performance. No gas leakages of the single cell stack occurred in the tests of gas detection and OCV measurement. The OCV and initial power of the stack were 1.09V and $0.45W/cm^2$, respectively, under the flow rates of air at 2,500 cc/min and $H_2$ at 1,000 cc/min at the test temperature of $750^{\circ}C$. A degradation rate of 44.0% was measured during the prolonged time of 307 h. The relatively low durability of the tested single cell stack was found to be the evaporation of Ag-mesh at the current corrector.

Preparation of High Energy Density Lithium Anode for Thermal Batteries and Electrochemical Properties Thereof (열전지용 고에너지 밀도 리튬 음극 제조 및 이의 전기화학적 특성)

  • Im, Chae-Nam;Yu, Hye-Ryeon;Yoon, HyunKi;Cho, Jang-Hyeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.398-406
    • /
    • 2022
  • In order to increase the electrochemical performance of thermal battery anode, LIFT anode having the same weight but a larger lithium content in electrodes was fabricated by mixing lithium, iron and titanium. By applying these electrodes, a single cell and a thermal battery were prepared, and the effect of LIFT anode on electrochemical performance was evaluated. The LIFT-applied single cell presented a better cell performance than LIFe-applied single cell at 500℃ and 550℃. The discharge performance of LIFT-applied single cell, which included the operating time (787s), specific capacity (1,683 Asg-1), and electrode utilization (80.7%), was improved collectively compared to the LIFe applied single cell (736s, 1,245 As g-1, and 74.6%) at 500℃. As the discharge progressed, the internal resistance of LIFT anode decreased, because the lithium migration path was formed due to the presence of large titanium particles among iron particles. These results were analyzed in terms of the microstructure of electrode using SEM. Energy density of LIFT-applied single cell also increased by 10% to 142.1 Wh kg-1 compared to that of LIFe-applied single cell (127.4 Wh kg-1). In addition, the LIFT-applied single cell presented a stable discharge performance for 6,500s without a short circuit which could occur by molten lithium under an open circuit voltage condition with a high pressure (4 kgf cm-2). As observed in the high temperature thermal battery performance tests, the voltage and specific capacity of LIFT-applied thermal battery are superior to those of LIFe-applied thermal batteries, indicating that the energy density of LIFT-applied thermal batteries should remarkably increase.