• Title/Summary/Keyword: Single cavity

Search Result 467, Processing Time 0.022 seconds

A Study of the Estimation Method for the Dielectric Properties of Dielectrics in Millimeter Wave Range using Bethe's Small Hole Coupling (Bethe's Small Hole Coupling을 이용한 유전체의 밀리미터파대 유전특성 평가방법에 관한 연구)

  • Lee, Hong-Yeol;Jun, Dong-Suk;Hahn, Jin-Woo;Lee, Sang-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1136-1139
    • /
    • 2002
  • The circular cavity resonator which can measure the dielectric properties of dielectrics in the Ka-band(26.5GHz~40GHz) frequency range was designed and fabricated. A structure of the resonator is divided into two equal parts of the length and the dielectric plate sample is placed between two halves. Exciting and detecting of the resonator is performed by WR28 rectangular waveguides using Bethe's small hole coupling. The GaAs plate sample, whose permittivity is known to be 13 in millimeter wave range, was used for the verification of the performance of the fabricated circular cavity resonator. In the measurement of GaAs single crystal using that resonator, the resonant frequency of the dominant $TE_{011}$ mode, the permittivity and $Q{\times}f_0$ were measured as 26.69GHz, 12.9 and 124,000GHz, respectively.

  • PDF

Shape Optimization of Cavitator for a Supercavitating Projectile Underwater (초공동(超空洞) 하의 수중 주행체 캐비테이터 형상최적설계)

  • Choi, Joo-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.82-85
    • /
    • 2008
  • When a projectile travels at high speed underwater, supercavitating flowarises, in which a huge cavity is generated behind the projectile so that only the nose, i.e., the cavitator, of the projectile is wetted, while the rest of it should be surrounded by the cavity. In that case, the projectile can achieve very high speed due to the reduced drag. Furthermore if the nose of the body is shaped properly, the attendant pressure drag can be maintained at a very low value, so that the overall drag is also reduced dramatically. In this study, shape optimization technique is employed to determine the optimum cavitator shape for minimum drag, given certain operating conditions. Simultaneous optimization technique is proposed for efficient cavitator shape optimization, in which the cavity and cavitator shape are determined in a single optimization routine.

  • PDF

Effect of channel hight on Bubble growth under Saturated Nucleate Pool Boiling for Various Channel Height using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면의 채널 높이가 풀비등시 기포성장에 미치는 영향에 대한 기초연구)

  • Kim, Jeong-Bae;Park, Moon-Hee;Jeon, Woo-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.93-99
    • /
    • 2010
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R113 for various channel heights under saturated pool condition. A circular heater of 1mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of channel height on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, and bubble shapes. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

A Study of the Estimation Method for the Dielectric Properties of Dielectrics in Millimeter Wave Range using Bethe's Small Hole Coupling (Bethe's Small Hole Coupling을 이용한 유전체의 밀리미터파대 유전특성 평가방법에 관한연구)

  • 이홍열;전동석;한진우;이상석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1085-1089
    • /
    • 2002
  • The circular cavity resonator which can measure the dielectric properties of dielectrics in the Ka-band(26.5GHz∼400Hz) frequency range was designed and fabricated. A structure of the resonator is divided into two equal parts of the length and the dielectric plate sample is placed between two halves. Exciting and detecting of the resonator is Performed by WR28 rectangular waveguides using Bethe's small hole coupling. The GaAs plate sample, whose performance is known to be 13 in millimeter wave range, was used for the verification of the performance of the fabricated circular cavity resonator In the measurement of GaAs single crystal using that resonator, the resonant frequency of the dominant TE$\sub$011/ mode, the permittivity and Q${\times}$f$\sub$0/ were measured as 26.69GHz, 12.9 and 124,000GHz, respectively.

Heat Transfer Characteristics under Saturated Nucleate Pool Boiling for Various Heating Surface Angles using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면 경사각에 따른 포화상태 풀 핵비등 열전달 기초연구)

  • Kim, Jeong-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.7-14
    • /
    • 2009
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R11 and R113 for various surface angles under saturated pool condition. A circular heater of 1 mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of surface angles on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, sliding velocity, bubble shape and advancing and receding contact angles. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

Study on the Wideband Tonpilz Transducer with a Cavity-Type Head Mass (중공형 전면추를 가진 Tonpilz 트랜스듀서 연구)

  • Kim, Hyunki;Lim, Youngsub;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.94-101
    • /
    • 2014
  • In this work, we present an underwater acoustic transducer with a cavity-type head mass to achieve a wide frequency bandwidth. We analyzed the effects of design variables on the transducer characteristics, and optimized the structure of the Tonpilz transducer based on the analysis results. Further, validity of the design was verified by manufacturing a prototype of the transducer and measuring its properties. The designed transducer had a far wider -6 dB fractional bandwidth which is 131 % than that of a single mode transducer, and the measured results were confirmed to be in good agreement with the analysis results.

Pile tip grouting diffusion height prediction considering unloading effect based on cavity reverse expansion model

  • Jiaqi Zhang;Chunfeng Zhao;Cheng Zhao;Yue Wu;Xin Gong
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.97-107
    • /
    • 2024
  • The accurate prediction of grouting upward diffusion height is crucial for estimating the bearing capacity of tip-grouted piles. Borehole construction during the installation of bored piles induces soil unloading, resulting in both radial stress loss in the surrounding soil and an impact on grouting fluid diffusion. In this study, a modified model is developed for predicting grout diffusion height. This model incorporates the classical rheological equation of power-law cement grout and the cavity reverse expansion model to account for different degrees of unloading. A series of single-pile tip grouting and static load tests are conducted with varying initial grouting pressures. The test results demonstrate a significant effect of vertical grout diffusion on improving pile lateral friction resistance and bearing capacity. Increasing the grouting pressure leads to an increase in the vertical height of the grout. A comparison between the predicted values using the proposed model and the actual measured results reveals a model error ranging from -12.3% to 8.0%. Parametric analysis shows that grout diffusion height increases with an increase in the degree of unloading, with a more pronounced effect observed at higher grouting pressures. Two case studies are presented to verify the applicability of the proposed model. Field measurements of grout diffusion height correspond to unloading ratios of 0.68 and 0.71, respectively, as predicted by the model. Neglecting the unloading effect would result in a conservative estimate.

The Role of Single-contrast CT for Management in Hemodynamically Stable Anterior Abdominal Stab wound Patients (혈역학적으로 안정된 복부 전벽 자상 환자의 개복 수술 결정에서 Single-contrast CT의 역할)

  • Jo, Janghwan;Kim, Joongsuck;Kim, Yeongcheol;Chung, Ilyong;Park, Jongmin;Ahn, Eunjung;Kim, Eunyoung;Park, Seihyeog;Kim, Seongyup
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.145-150
    • /
    • 2014
  • Purpose: To assess the accuracy and role of single-contrast computed tomography (CT) in the management of anterior abdominal stab wound (AASW). Methods: During 8-years period, single-contrast CT was performed in 21 hemodynamically stable AASW patients (age range, 22-64 years; median age, 45 years), including 19 men and 2 women. CT scans were evaluated by one trauma surgeon and one senior resident to determine the depth of injury(peritoneal violation or not), and abnormal findings of intraperitoneal cavity associated with stab injury. We retrospectively reviewed medical records regarding operative findings. Results: Nine patients underwent abdominal surgery and 12 patients nonoperative management. In the abdominal surgery group, abnormal CT findings included peritoneal violation in 14 patients and abnormal intraperitoneal cavity findings in 5 patients. There was no statistical significant difference regarding abnormal CT findings between abdominal surgery group and nonoperative management group. Among the nine abdominal surgery patients, therapeutic laparotomy was performed on 4 patients. The positive predictive value (PPV) and negative predictive value (NPV) of peritoneal violation to predictive therapeutic laparotomy were 28.6% and 100%, respectively. In addition, the PPV and NPV of abnormal intraperitoneal cavity CT findings to predict therapeutic laparotomy were 40.0% and 87.5%, respectively. There was no statistical significant difference regarding the abnormal CT findings between therapeutic laparotomy group and non therapeutic laparotomy group. Conclusion: CT is a good adjunctive method to evaluate hemodynamicaly stable AASW patients. If peritoneal violation is not seen on CT scan, conservative treatment on local wound may be safely performed without additional abdominal surgery. However, further study is warranted to evaluate the exact role of CT in the diagnostic workup of AASW patients.

Synthesis and Crystal Structure of Zinc Iodide in the Sodalite Cavities of Zeolite A (LTA)

  • Kim, Seok-Han;Park, Man;Son, Young-Ja;Lee, Hyung-Joo;Jeong, Gyo-Cheol;Bae, Myung-Nam;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.567-573
    • /
    • 2007
  • The crystal structure of ZnI2 molecule synthesized in zeolite A (LTA) has been studied by single-crystal X-ray diffraction techniques. A single crystal of |Zn6|[Si12Al12O48]-LTA, synthesized by the dynamic ion-exchange of |Na12|[Si12Al12O48]-LTA with aqueous 0.05 M Zn(NO3)2 and washed with deionized water, was placed in a stream of flowing 0.05 M KI in CH3OH at 294 K for four days. The resulting crystal structure of the product (|K6Zn3(KI)3(ZnI2)0.5|[Si12Al12O48]-LTA, a = 12.1690(10) A) was determined at 294 K by single-crystal X-ray diffraction in the space group Pm3m. It was refined with all measured reflections to the final error index R1 = 0.078 for 431 reflections which Fo > 4σ (Fo). At four crystallographically distinct positions, 3.5 Zn2+ and nine K+ ions per unit cell are found: three Zn2+ and five K+ ions lie on the 3-fold axes opposite 6-rings in the large cavity, two K+ ions are off the plane of the 8-rings, two K+ ions are recessed deeply off the plane of the 8-rings, and the remaining a half Zn2+ ion lie on the 3-fold axes opposite 6-rings in the sodalite cavity. A half Zn2+ ion and an I- ion per unit cell are found in the sodalite units, indicating the formation of a ZnI2 molecule in 50% of the sodalite cavities. Each ZnI2 (Zn-I = 3.35(5) A) is held in place by the coordination of its one Zn2+ ion to the zeolite framework oxygens and by the coordination of its two I- ions to K+ ions through 6-rings (I-K = 3.33(8) A). Three additional I- ions per unit cell are found opposite a 4-ring in the large cavity and form a K3I2+ and two K2ZnI3+ ionic clusters, respectively.

Bidirectional Hybrid DWDM-PON for HDTV/Gigabit Ethernet/CATV Applications

  • Lu, Hai-Han;Tsai, Wen-Shing;Chien, Tzu-Shen;Chen, Shih-Hung;Chi, Yu-Chieh;Liao, Che-Wei
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.162-168
    • /
    • 2007
  • A new scheme for bi-directional HDTV/Gigabit Ethernet/CATV transmission over a hybrid dense-wavelength-division-multiplexing passive optical network (DWDM-PON) is proposed and demonstrated. It is based on injection-locked vertical-cavity surface-emitting lasers and distributed-feedback laser diodes as transmitters. Services with 129 HDTV channels, a 1.25 Gbps Gigabit Ethernet connection, and 77 CATV channels are successfully demonstrated over 40 km single-mode fiber links. Good performance of bit error rate, carrier-to-noise ratio, composite second order, and composite triple beat is achieved in our proposed bidirectional DWDM-PON.

  • PDF