• Title/Summary/Keyword: Single cam

Search Result 114, Processing Time 0.02 seconds

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Effects of load variation on a Kaplan turbine runner

  • Amiri, K.;Mulu, B.;Cervantes, M.J.;Raisee, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.182-193
    • /
    • 2016
  • Introduction of intermittent electricity production systems like wind and solar power to electricity market together with the deregulation of electricity markets resulted in numerous start/stops, load variations and off-design operation of water turbines. Hydraulic turbines suffer from the varying loads exerted on their stationary and rotating parts during load variations since they are not designed for such operating conditions. Investigations on part load operation of single regulated turbines, i.e., Francis and propeller, proved the formation of a rotating vortex rope (RVR) in the draft tube. The RVR induces pressure pulsations in the axial and rotating directions called plunging and rotating modes, respectively. This results in oscillating forces with two different frequencies on the runner blades, bearings and other rotating parts of the turbine. This study investigates the effect of transient operations on the pressure fluctuations exerted on the runner and mechanism of the RVR formation/mitigation. Draft tube and runner blades of the Porjus U9 model, a Kaplan turbine, were equipped with pressure sensors for this purpose. The model was run in off-cam mode during different load variations. The results showed that the transients between the best efficiency point and the high load occurs in a smooth way. However, during transitions to the part load a RVR forms in the draft tube which induces high level of fluctuations with two frequencies on the runner; plunging and rotating mode. Formation of the RVR during the load rejections coincides with sudden pressure change on the runner while its mitigation occurs in a smooth way.

Risk of Gastric Cancer in Children with Helicobacter pylori Infection

  • Cam, Sebahat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9905-9908
    • /
    • 2014
  • Background: Helicobacter pylori (H. pylori) is the most common chronic infectious agent in the stomach. Most importantly, it may lead to atrophy, metaplasia and cancer. The aim of this study was to investigate the incidence of H. pylori infection and to detect early mucosal changes that may lead to malignant degeneration in children. Materials and Methods: Children who underwent upper gastrointestinal endoscopy were included. Familial history of gastric cancer was noted. Endoscopic examinations were performed by a single pediatric gastroenterologist. A minimum of three biopsy samples were collected during endoscopy. The patients were accepted as H. pylori infected if results of biopsies and rapid urease test were both positive. Biopsies were evaluated for the presence and degree of chronic inflammation, the activity and severity of gastritis, glandular atrophy and intestinal metaplasia. Results: A total of 750 children (388 boys, 362 girls) were evaluated in our study, with a mean age of 10.1 years. A total of 390 patients (52%) were found to be infected with H. pylori. Among the H. pylori infected patients, 289 (74%) were diagnosed to have chronic superficial gastritis, 24 (6.2%) had gastric atrophy. Most strikingly, intestinal metaplasia was observed in 11 children, all were in the H. pylori positive group. There was no difference in the mean of age, gender and socioeconomic class between H. pylori infected and non-infected groups. The frequency of gastric cancer in family members (4 in number) was higher in patients with H. pylori infection. No gastric cancer case was reported from the parents of non-infected children. The worst biopsy parameters (atropy and metaplasia) were improved after H. pylori eradication on control endoscopy. Conclusions: The current study shows a higher prevalence of familial history of gastric cancer in H. pylori infected children. Intestinal metaplasia was also higher in the infected children. Eradication of H. pylori infection for this risk group may prevent subsequent development of gastric cancer.

Integrated CAD System for Ship and Offshore Projects

  • Suh, Heung-Won;Lee, Sung-Geun
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • Nowadays major shipbuilding companies are trying to expand their business not only to shipbuilding but to offshore projects as well. DSME is one of them. DSME is trying to set up a flexible design and construction environment for shipbuilding and offshore construction in a single shipyard. The shipbuilding and offshore projects, however, have their unique technology but they need to be designed and constructed in one site. To support this new requirement, DSME has developed an integrated CAD system for ship and offshore projects. In this integrated design environment, the designers can design commercial ships and offshore projects in a flexible manner. Concurrent design is very important for ship and offshore design. As compared to the complexity of the product, the design period is quite short. In effect, the design system for the ship and offshore project has to support concurrent design. One essential point of concurrent design environment is a product model based design system. DSME has developed and implemented the 3D product model concurrent design environment based on Tribon M3. Tribon is a widely used CAD system in shipbuilding area that is developed by Tribon Solutions. DSME has both customized the Tribon system and developed in-house application systems to support its own design and production procedures. All the design objects are modeled in one common database to support concurrent design and accurate production. The major in-house development focused on the modeling automation and automatic drawing generation. During the drawing generation process many of the additional production information are also extracted from the 3D product model. In addition, several applications and functionalities have been developed to apply the shipbuilding based Tribon M3 system to offshore projects. The development of shape nesting, tubular connection, isometric drawing, grating nesting systems are the typical.

Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure load

  • Prott, Lea Sophia;Spitznagel, Frank Akito;Bonfante, Estevam Augusto;Malassa, Meike Anne;Gierthmuehlen, Petra Christine
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.269-280
    • /
    • 2021
  • PURPOSE. The objective of this study was to evaluate the effect of thickness reduction and fatigue on the failure load of monolithic zirconia crowns. MATERIALS AND METHODS. 140 CAD-CAM fabricated crowns (3Y-TZP, inCorisTZI, Dentsply-Sirona) with different ceramic thicknesses (2.0, 1.5, 1.0, 0.8, 0.5 mm, respectively, named G2, G1.5, G1, G0.8, and G0.5) were investigated. Dies of a mandibular first molar were made of composite resin. The zirconia crowns were luted with a resin composite cement (RelyX Unicem 2 Automix, 3M ESPE). Half of the specimens (n = 14 per group) were mouth-motion-fatigued (1.2 million cycles, 1.6 Hz, 200 N/ 5 - 55℃, groups named G2-F, G1.5-F, G1-F, G0.8-F, and G0.5-F). Single-load to failure was performed using a universal testing-machine. Fracture modes were analyzed. Data were statistically analyzed using a Weibull 2-parameter distribution (90% CI) to determine the characteristic strength and Weibull modulus differences among the groups. RESULTS. Three crowns (21%) of G0.8 and five crowns (36%) of G0.5 showed cracks after fatigue. Characteristic strength was the highest for G2, followed by G1.5. Intermediate values were observed for G1 and G1-F, followed by significantly lower values for G0.8, G0.8-F, and G0.5, and the lowest for G0.5-F. Weibull modulus was the lowest for G0.8, intermediate for G0.8-F and G0.5, and significantly higher for the remaining groups. Fatigue only affected G0.5-F. CONCLUSION. Reduced crown thickness lead to reduced characteristic strength, even under failure loads that exceed physiological chewing forces. Fatigue significantly reduced the failure load of 0.5 mm monolithic 3Y-TZP crowns.

A case report of single crown restoration using an intraoral scanner for occlusal evaluation (단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고)

  • Song, Jun-Beom;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung;Choi, Sun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Survival Effect of Complete Multimodal Therapy in Malignant Pleural Mesothelioma

  • Sayan, Muhammet;Bas, Aynur;Turk, Merve Satir;Ozkan, Dilvin;Celik, Ali;Kurul, Ismail Cuneyt;Tastepe, Abdullah Irfan
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.405-412
    • /
    • 2022
  • Background: Malignant pleural mesothelioma (MPM) is an aggressive pleural malignancy, and despite all multimodal treatment modalities, the 5-year overall survival rate of patients with MPM is less than 20%. In the present study, we aimed to analyze the surgical and prognostic outcomes of patients with MPM who received multimodal treatment. Methods: In this retrospective, single-center study, the records of patients who underwent surgery for MPM between January 2010 and December 2020 at our department were reviewed retrospectively. Results: Sixty-four patients were included in the study, of whom 23 (35.9%) were women and 41 (64.1%) were men. Extrapleural pneumonectomy, pleurectomy/decortication, and extended pleurectomy/decortication procedures were performed in 34.4%, 45.3%, and 20.3% of patients, respectively. The median survival of patients was 21 months, and the 5-year survival rate was 20.2%. Advanced tumor stage (hazard ratio [HR], 1.8; p=0.04), right-sided extrapleural pneumonectomy (HR, 3.1; p=0.02), lymph node metastasis (HR, 1.8; p=0.04), and incomplete multimodal therapy (HR, 1.9; p=0.03) were poor prognostic factors. There was no significant survival difference according to surgical type or histopathological subtype. Conclusion: Multimodal therapy can offer an acceptable survival rate in patients with MPM. Despite its poor reputation in the literature, the survival rate after extrapleural pneumonectomy, especially left-sided, was not as poor as might be expected.

Estimation of two-dimensional position of soybean crop for developing weeding robot (제초로봇 개발을 위한 2차원 콩 작물 위치 자동검출)

  • SooHyun Cho;ChungYeol Lee;HeeJong Jeong;SeungWoo Kang;DaeHyun Lee
    • Journal of Drive and Control
    • /
    • v.20 no.2
    • /
    • pp.15-23
    • /
    • 2023
  • In this study, two-dimensional location of crops for auto weeding was detected using deep learning. To construct a dataset for soybean detection, an image-capturing system was developed using a mono camera and single-board computer and the system was mounted on a weeding robot to collect soybean images. A dataset was constructed by extracting RoI (region of interest) from the raw image and each sample was labeled with soybean and the background for classification learning. The deep learning model consisted of four convolutional layers and was trained with a weakly supervised learning method that can provide object localization only using image-level labeling. Localization of the soybean area can be visualized via CAM and the two-dimensional position of the soybean was estimated by clustering the pixels associated with the soybean area and transforming the pixel coordinates to world coordinates. The actual position, which is determined manually as pixel coordinates in the image was evaluated and performances were 6.6(X-axis), 5.1(Y-axis) and 1.2(X-axis), 2.2(Y-axis) for MSE and RMSE about world coordinates, respectively. From the results, we confirmed that the center position of the soybean area derived through deep learning was sufficient for use in automatic weeding systems.

Theoretical Study on the Hydrogen-Bonding Effect of H2On-H2Om (n=1-4, m=1-4) Dimers (H2On-H2Om (n=1-4, m=1-4) 이중합체의 수소결합에 따른 구조적 특성 및 결합에너지에 관한 이론 연구)

  • Song, Hui-Seong;Seo, Hyun-Il;Shin, Chang-Ho;Kim, Seung-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • The DFT and ab initio calculations have been performed to elucidate hydrogen interaction of hydrogen polyoxide dimers, $H_2O_n-H_2O_m$ (n=1-4, m=1-4). The optimized geometries, harmonic vibrational frequencies, and binding energies are predicted at various levels of theory. The harmonic vibrational frequencies of the molecules considered in this study show all real numbers implying true minima. The higher-order correlation effect were discussed to compare MP2 result with CCSD(T) single point energy. The binding energies were corrected for the zero-point vibrational energy (ZPVE) and basis set superposition errors (BSSE). The largest binding energy predicted at the CCSD(T)/cc-pVTZ level of theory is 8.18 kcal/mol for $H_2O_4-H_2O_3$ and the binding energy of water dimer is predicted to be 3.00 kcal/mol.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.