• Title/Summary/Keyword: Single Port

Search Result 483, Processing Time 0.024 seconds

Unified DC Offset Cancellation and I/Q Regeneration with Carrier Phase Recovery in Five-Port Junction based Direct Receivers (Five-port 접합을 이용한 RF 수신기를 위한 동시 DC 오프셋 제거와 I/Q 신호 재생 알고리즘)

  • Park, Hyung-Chul;Lim, Hyung-Sun;Yu, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.64-70
    • /
    • 2007
  • This paper presents a novel unified DC offset cancellation and I/Q regeneration for five-port junction based direct receivers. It utilizes the symmetry characteristics of the single-frequency continuous-wave (CW) signal, making it possible that the proposed method can be used regardless of carrier phase offset. The proposed method eliminates the additional DC offset cancellation and reduces the I/Q regeneration parameter estimation time. Since the proposed method employs a single-frequency CW signal independent of the modulation scheme, five-port junction based direct receivers can be used for the demodulation of orthogonal frequency-division multiplexing and continuous phase modulation as well as phase shift-keying.

Design of a Monopulse Feed for $2{\times}2$ Array Feed horn Antenna ($2{\times}2$배열 피드혼 안테나용 모노 펄스 피드 설계)

  • Kim, Won-Sub
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.91-96
    • /
    • 2008
  • In this paper, a monopulse fled for three mode $2{\times}2$ array feed horn antenna was designed. Gain of single feed was 8.25dB. Increasing property of gain and rectangular waveguide and reflection of free space is decreased because it has structure extending to electric plane at connected part from transformation to free space. When fled port1 and port2 is placed vertically and thickness of aperture hem is reduced, isolation is satisfied with property of lower -25dB. Also, at higher frequency, it is confirmed that isolation is improved. Combination of electric field occurs less influence because port1 and port3 is placed horizontally and distribution of electric field is connected to parallel. However, because of combination of electric field, it is more improved from 2dB to 6dB than isolation of port1 and port2. Direct combination occult less effect at port1 and port4 than effect of port2 and port3, it is lower -35dB.

Single-port Video-Assisted Thoracic Surgery for Lung Cancer

  • Kang, Do Kyun;Min, Ho Ki;Jun, Hee Jae;Hwang, Youn Ho;Kang, Min Kyun
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.299-301
    • /
    • 2013
  • Video-assisted thoracic surgery (VATS) is a minimally invasive technique that has many advantages in postoperative pain and recovery time. Because of its advantages, VATS is one of the surgical techniques widely used in patients with lung cancer. Most surgeons perform VATS for lung cancer with three or more incisions. As the technique of VATS has evolved, single-port VATS for lung cancer has been attempted and its advantages have been reported. We describe our experiences of VATS for lung cancer with a single incision in this report.

Video-Assisted Thoracic Surgery Thymectomy: Subxiphoid Approach

  • Cho, Sukki
    • Journal of Chest Surgery
    • /
    • v.54 no.4
    • /
    • pp.314-318
    • /
    • 2021
  • In this paper, I present the technique of subxiphoid single-port video-assisted thoracic surgery (VATS) thymectomy for thoracic surgeons to perform this procedure safely. This procedure is indicated for all anterior mediastinal masses and may be extended to lung cancer. The patient is placed in the lithotomy position, and the operator should be on the midline. Below the xiphoid process, a skin incision is made 4-5 cm horizontally at a single thumb's width down. Under two-lung ventilation, CO2 is insufflated, maintaining 10 mm Hg. The fat tissue and thymic tissue are all resected from the sternum and pericardium between both phrenic nerves using an articulated grasper and an energy device. After retrieval of the mass with a wrap bag, a Jackson-Pratt drain is inserted instead of a chest tube. One of the advantages of this procedure is less postoperative pain than intercostal VATS. The subxiphoid approach can be used for bilateral pneumothorax, bilateral pulmonary metastasectomy, and simple lobectomy for both upper lobes and the right middle lobe.

A High-Isolation MIMO Antenna with Dual-Port Structure for 5G Mobile Phones

  • Yang, Hyung-kyu;Lee, Won-Woo;Rhee, Byung-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1458-1470
    • /
    • 2018
  • In this letter, a new dual-port Multiple-Input Multiple-Output (MIMO) antenna is introduced which has two independent signal feeding ports in a single antenna element to achieve smaller antenna volumes for the 5G mobile applications. The dual-port structure is implemented by adding a cross coupled semi-loop (CCSL) antenna as the secondary radiator to the ground short of inverted-F antenna (IFA). It is found that the port to port isolation is not deteriorated when an IFA and CCSL is combined to form a dual-port structure. The isolation property of the proposed antenna is compared with a polarization diversity based dual-port antenna proposed in the literature [9]. The operating frequency range is 3.3-4.0 GHz which is suitable for places where $4{\times}4$ MIMO systems are supposed to be deployed such as in China, EU, Korea and Japan at the band ${\times}$ (3.3 - 3.8GHz. The measured 6-dB impedance bandwidths of the proposed antennas are larger than 700 MHz with isolation between the feeding ports higher than 18 dB [1-2]. The simulation and measurement results show that the proposed antenna concept is a very promising alternative for 5G mobile applications.

Extraction of Substrate Resistance Parameters for RF MOSFETs Based on Three-Port Measurement

  • Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.809-812
    • /
    • 2005
  • In this work, a new method for extracting substrate parameters of RF MOSFETs based on 3-port measurement is presented using device simulation. A T-type substrate resistance network is used. 3-port Y-parameter analyses were performed on the equivalent circuit of RF MOSFETs. All the components in the RF MOSFETs when the device is turned off were extracted directly from the 3-port device simulation data. The small-signal output admittance $Y_{22}$ can be well modeled up to 40 GHz. From the 3-port simulation and modeling results, it was verified that the proposed equivalent circuit and parameter extraction method was more accurate than the single substrate resistance model.

  • PDF

Instroduction of Automatic Container Terminal designed by Japan (일본의 자동화 터미널 시설계 소개)

  • 정영석;진규호
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.19-49
    • /
    • 1998
  • I try to introduce three types of designs for automatic container operating system which are designed by Institute of Japan Port Research in 1996. Each types are designedto fit with the situations of Japan Port. 'A'type of these designs adapts Dual Container Crane, AGV, RMG, etc. 'B'type of these designs adapts Dual Container Crane, AGV, OHBC, RTG. And 'C'type of these designs adapts Single Container Crane, AGV, OHBC, etc. Even if three designs are introduced, they have some problems to solve for the future. They are Lashing work, Refeer container problem, check for container and seal in main gate, Establishing EDI NETWORK, etc. I expect that this paper will be a helps to development of our port industry.

  • PDF

Non-Isolated Unidirectional Three-Port Cuk-Cuk Converter for Fuel Cell/Solar PV Systems

  • Chandrasekar, Balaji;Chellammal, N.;Nallamothu, Bhargavi
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1278-1288
    • /
    • 2019
  • A DC-DC Non-Isolated Three-Port Cuk-Cuk (NI-TPCC) converter for interfacing renewable energy sources (RESs) such as Fuel Cell (FC) and Photovoltaic (PV) energy with a DC load is presented in this paper. It features single-stage power conversion from both of the input ports to the load port. The proposed NI-TPCC converter is designed based on the classical Cuk converter. The operational modes and power flow are analyzed in the continuous conduction mode (CCM), and the relationships among the port voltages are derived. Continuous currents in all three ports with less ripple enhance the performance of a fuel cell and its operating life. Furthermore, the output inductor is shared with both of the input ports, which reduces the number of active and passive components. The effectiveness of the designed NI-TPCC converter has been validated through simulation and experimental results.

A Comparative Study on Productivity of Next Generation Quay Crane in Container Terminal (컨테이너 터미널의 차세대 안벽크레인 생산성 비교분석)

  • Ha Tae-Young;Choi Yong-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.297-302
    • /
    • 2004
  • This paper analyzed productivity of quay cranes on container terminal that have perpendicular yard layout block. In most existing container terminals, quay cranes of single trolley type are used to loading and unloading containers, but quay crane productivity of these type has many limitation about large size containership. For these reasons, recently quay cranes of various type that mn improve productivity are developed and as the representative example, dual trolley, double trolley, supertainer are developing. These cranes are realized that very high productivity bemuse their cycle time is short more than existent single trolley quay crane. Therefore, we analyzed productivity of these cranes that are realized by next generation crane alternatives and as result qf this research, mechaniml productivity by cycle time and net productivity by simulation were measured.

  • PDF

Clinical experience with single-port access laparoscopic cystectomy and myomectomy

  • Jeong, Jae-Hyeok;Kim, Yu-Ri;Hong, Kil-Pyo;Ha, Jae-Eun;Kim, Eun-Jeong;Hong, Da-Kyo;Lee, Kyu-Sup
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.1
    • /
    • pp.44-50
    • /
    • 2016
  • Objective: This study was performed to assess our clinical experience with single-port access (SPA) laparoscopic cystectomy and myomectomy and the surgical outcomes of those procedures at our institution. Methods: The authors evaluated the surgical outcomes of SPA laparoscopic cystectomy in 293 patients and SPA laparoscopic myomectomy in 246 patients. The surgical outcomes comprised operation time, the amount of blood loss during the operation, the change in hemoglobin (before and after the operation), the change in hematocrit (before and after the operation), switching to the multi-port access method, complications, transfusions, and the duration of the postoperative hospital stay. Results: The Pearson correlation coefficient and the Spearman correlation coefficient between the operation time and the amount of blood loss were 0.312 and 0.321 for SPA laparoscopic cystectomy, respectively, and 0.706 and 0.674 for SPA laparoscopic myomectomy, respectively. The drops in hemoglobin and hematocrit were $1.33{\pm}0.78g/dL$ and $4.14%{\pm}2.45%$, respectively, in SPA laparoscopic cystectomy, while the corresponding figures were $1.34{\pm}1.13g/dL$ and $4.17%{\pm}3.24%$ in SPA laparoscopic myomectomy, respectively. Conclusion: This study reported the surgical outcomes of SPA laparoscopic cystectomy and myomectomy and compared them to previously published findings on traditional laparoscopic cystectomy and myomectomy. No significant differences were found in the surgical outcomes between SPA and traditional laparoscopic cystectomy and myomectomy.