• 제목/요약/키워드: Single Junction

검색결과 308건 처리시간 0.028초

R&D activities of a-Si:H thin film solar cells by LG Electronics

  • Lee, Don-Hui
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 한국표면공학회 2007년도 춘계학술발표회 초록집
    • /
    • pp.19-19
    • /
    • 2007
  • Recently, we have developed p-i-n hydrogenated amorphous silicon (a-Si:H) single junction (SJ) thin film solar cells with RF (13,56MHz) plasma enhanced chemical vapor deposition (PECVD) systems, and also successfully fabricated the mini-modules (>300$cm^2$), using laser scribing technique to form an integrated series connection, The efficiency of a mini-module was 7.4% (Area=305$cm^2$, $I_{SC}$=0.25A, $V_{OC}$=14.74V, FF=62%).

  • PDF

Single Magnetic Bead Detection in a Microfluidic Chip Using Planar Hall Effect Sensor

  • Kim, Hyuntai;Reddy, Venu;Kim, Kun Woo;Jeong, Ilgyo;Hu, Xing Hao;Kim, CheolGi
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.10-14
    • /
    • 2014
  • In this study, we fabricate an integrated microfluidic chip with a planar Hall effect (PHE) sensor for single magnetic bead detection. The PHE sensor was constructed with a junction size of $10{\mu}m{\times}10{\mu}m$ using a trilayer structure of Ta(3 nm)/NiFe(10 nm)/Cu(1.2 nm)/IrMn(10 nm)/Ta(3 nm). The sensitivity of the PHE sensor was 19.86 ${\mu}V/Oe$. A diameter of 8.18 ${\mu}m$ magnetic beads was used, of which the saturation magnetization was ~2.1 emu/g. The magnetic susceptibility ${\chi}$ of these magnetic beads was calculated to be ~0.14. The diluted magnetic beads solution was introduced to the microfluidic channel attributing a single bead flow and simultaneously the PHE sensor voltage was measured to be 0.35 ${\mu}V$. The integrated microchip was able to detect a magnetic moment of $1.98{\times}10^{-10}$ emu.

Design of a 94-GHz Single Balanced Mixer Using Planar Schottky Diodes with a Nano-Dot Structure on a GaAs Substrate

  • Uhm, Won-Young;Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of information and communication convergence engineering
    • /
    • 제14권1호
    • /
    • pp.35-39
    • /
    • 2016
  • In this paper, we develop a 94-GHz single balanced mixer with low conversion loss using planar Schottky diodes on a GaAs substrate. The GaAs Schottky diode has a nanoscale anode with a T-shaped disk that can yield high cutoff frequency characteristics. The fabricated Schottky diode with an anode diameter of 500 nm has a series resistance of 21 Ω, an ideality factor of 1.32, a junction capacitance of 8.03 fF, and a cutoff frequency of 944 GHz. Based on this technology, a 94-GHz single balanced mixer was constructed. The fabricated mixer shows an average conversion loss of -7.58 dB at an RF frequency of 92.5 GHz to 95 GHz and an IF frequency of 500 MHz with an LO power of 7 dBm. The RF-to-LO isolation characteristics were greater than -32 dB. These values are considered to be attributed to superior Schottky diode characteristics.

An Experimental Study About Interaction of Droplet Array Combustion (액적배열연소의 상호간섭에 관한 실험적 연구)

  • Kim, Heung-Sik;Baek, Seung-Wook;Park, Jun-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제26권10호
    • /
    • pp.1355-1363
    • /
    • 2002
  • An experimental study was conducted to investigate the interaction phenomena of droplet array combustion in ambient environment. The droplet with 1 mm in diameter was supported from an optical fiber and ignited with a hot wire. Combustion lifetimes and burning rate constants were measured for fuel of nheptane according to parameters, which were junction and suspender spacings, and array configuration. Results show that the burning process considerably depends on the initial away configuration. The d$^2$-law is found to be correct when applied to both of the droplets in away and the single droplet. For separation distance of about 5mm, there exists a critical state. So the transition from a merged flame to separated flames occurs and burning velocity is much faster than before. Combustion lifetime of the lower droplet is shorter than that of the upper droplet in the two-dimensional arrays combustion. Burning rate constants of the droplets in arrays are smaller than that of the single droplet, while they become higher as separation distance increases. Combustion lifetimes of the droplets in arrays are longer than that of the single droplet and decrease as separation distance increase. It is concluded that the array configuration and the mergedness of the flame are the most important factors governing multi-droplet combustion.

Surgical Management with Radiation Therapy for Metastatic Spinal Tumors Located on Cervicothoracic Junction : A Single Center Study

  • Park, Ho-Young;Lee, Sun-Ho;Park, Se-Jun;Kim, Eun-Sang;Lee, Chong-Suh;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권1호
    • /
    • pp.42-49
    • /
    • 2015
  • Objective : The cervicothoracic junction (CTJ) is a biomechanically and anatomically complex region that has traditionally posed problems for surgical access. In this retrospective study, we describe our clinical experiences of the treatment of metastatic spinal tumors at the CTJ and the results. Methods : From June 2006 to December 2011, 23 patients who underwent surgery for spinal tumors involving the CTJ were enrolled in our study. All of the patients were operated on through the posterior approach, and extent of resection was classified as radical, debulking, and simple neural decompression. Adjuvant radiation therapy (RT) was also considered. Visual analog scale score for pain assessment and Medical Research Council (MRC) grade for motor weakness were used, while pre- and post-operative performance status was evaluated using the Eastern Cooperative Oncology Group (ECOG). Results : Almost all of the patients were operated using palliative surgical methods (91.3%, 21/23). Ten complications following surgery occurred and revision was performed in four patients. Of the 23 patients of this study, 22 showed significant pain relief according to their visual analogue scale scores. Concerning the aspect of neurological and functional recovery, mean MRC grade and ECOG score was significantly improved after surgery (p<0.05). In terms of survival, radiation therapy had a significant role. Median overall survival was 124 days after surgery, and the adjuvant-RT group (median 214 days) had longer survival times than prior-RT (63 days) group. Conclusion : Although surgical procedure in CTJ may be difficult, we expect good clinical results by adopting a palliative posterior surgical method with appropriate preoperative preparation and postoperative treatment.

Outcomes of Abdominal Total Gastrectomy for Type II and III Gastroesophageal Junction Tumors: Single Center's Experience in Korea

  • Kim, Kyoung-Tai;Jeong, Oh;Jung, Mi-Ran;Ryu, Seong-Yeop;Park, Young-Kyu
    • Journal of Gastric Cancer
    • /
    • 제12권1호
    • /
    • pp.36-42
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the surgical outcomes of abdominal total gastrectomy, without mediastinal lymph node dissection for type II and III gastroesophageal junction (GEJ) cancers. Materials and Methods: We retrospectively reviewed surgical outcomes in 67 consecutive patients with type II and III GEJ cancers that were treated by the surgical resection between 2004 and 2008. Results: Thirty (45%) patients had type II and 37 (55%) had type III tumor. Among the 65 (97%) patients with curative surgery, 21 (31%) patients underwent the extended total gastrectomy with trans-hiatal distal esophageal resection, and in 44 (66%) patients, abdominal total gastrectomy alone was done. Palliative gastrectomy was performed in two patients due to the accompanying peritoneal metastasis. The postoperative morbidity and mortality rates were 21.4% and 1.5%, respectively. After a median follow up of 36 months, the overall 3-years was 68%, without any differences between the Siewert types or the operative approaches (transhiatal approach vs. abdominal approach alone). On the univariate analysis, the T stage, N stage and R0 resection were found to be associated with the survival, and multivariate analysis revealed that the N stage was a poor independent prognostic factor for survival. Conclusions: Type II and III GEJ cancers may successfully be treated with the abdominal total gastrectomy, without mediastinal lymph node dissection in the Korean population.

A FINITE ELEMENT ANALYSIS OF THE CENTER OF RESISTANCE OF A MAXILLARY FIRST MOLAR (상악 제일대구치의 저항중심에 관한 유한요소법적 분석)

  • Cho, Jeong-Hyeon;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • 제23권2호
    • /
    • pp.263-273
    • /
    • 1993
  • The purpose of this study was to analyse the center of resistance of the maxillary first molar using the 3-dimension finite element method. An extracted maxillary first molar of normal shape and average root length was selected and sectioned every 1.5mm parallel to the cementoenamel junction. Each section was traced and digitized to construct 3-D finite element model of the maxillary first molar. After a certain magnitude of counterbalancing moment(M) was applied to the tooth, a varying single force(F) of distomesial direction was applied to a certain point of th tooth until the tooth was translated. The force producing translation(Ft) was substituted to the equation ${\Delta}d=M/Ft$ to calculate the center of resistance of the maxillary first molar. And reducing the alveolar bone level 1.68mm, and 3.36mm below to the cementoenamel junction, the tooth movement was analysed to see the effect of reducing the alveolar bone level to the location of the center of resistance. The results were as follows ; 1. The center of resistance of the maxillary first molar was 3.72mm apical, 1.10mm buccal, and 0.71mm mesial to the geometric center of the horizontally sectioned surface at the cementoenamel junction. This point was 0.36mm apical, 1.20mm buccal, and 0.71mm mesial to the trifurcation point, indicating that it was not on the tooth root. 2. As the alveolar bone level was reduced, the center of resistance of the maxillary first molar was moved to the apical direction.

  • PDF

GaInP/GaAs/Ge Triple Junction Solar Array Power Performance Evaluation on Geostationary Orbit (GaInP/GaAs/Ge 3중 접합 태양전지 배열기의 정지궤도에서 전력 성능 평가)

  • Koo, Ja-Chun;Park, Hee-Sung;Lee, Na-Young;Cheon, Yee-Jin;Cha, Han-Ju;Moon, Gun-Woo;Ra, Sung-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제42권12호
    • /
    • pp.1057-1064
    • /
    • 2014
  • The satellite on geostationary orbit accommodates multiple payloads into a single spacecraft platform and launched in June 26, 2010. The electrical power required to the satellite during sunlight is generated by a solar array wing. The solar cells are the GaInP/GaAs/Ge Triple Junction cells named Gaget2 cells from RWE Space, which were based on a Spectrolab epitaxy. This paper evaluates solar array power performance at end of design life based on the trend analysis results for the flight data on geostationary orbit. The estimated solar array power performance at end of design life compares with the power performance provided by solar array manufacturer. The solar cells show nominal behavior without significant degradation through the trend analysis results.

Fundamental Metrology by Counting Single Flux and Single Charge Quanta with Superconducting Circuits

  • Niemeyer, J.
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.1-9
    • /
    • 2002
  • Transferring single flux quanta across a Josephson junction at an exactly determined rate has made highly precise voltage measurements possible. Making use of self-shunted Nb-based SINIS junctions, programmable fast-switching DC voltage standards with output voltages of up to 10 V were produced. This development is now extended from fundamental DC measurements to the precise determination of AC voltages with arbitrary waveforms. Integrated RSFQ circuits will help to replace expensive semiconductor devices for frequency control and signal coding. Easy-to-handle AC and inexpensive quantum voltmeters of fundamental accuracy would be of interest to industry. In analogy to the development in the flux regime, metallic nanocircuits comprising small-area tunnel junctions and providing the coherent transport of single electrons might play an important role in quantum current metrology. By precise counting of single charges these circuits allow prototypes of quantum standards for electric current and capacitance to be realised. Replacing single electron devices by single Cooper pair circuits, the charge transfer rates and thus the quantum currents could be significantly increased. Recently, the principles of the gate-controlled transfer of individual Cooper pairs in superconducting A1 devices in different electromagnetic environments were demonstrated. The characteristics of these quantum coherent circuits can be improved by replacing the small aluminum tunnel Junctions by niobium junctions. Due to the higher value of the superconducting energy gap ($\Delta_{Nb}$$7\Delta_{Al}$), the characteristic energy and the frequency scales for Nb devices are substantially extended as compared to A1 devices. Although the fabrication of small Nb junctions presents a real challenge, the Nb-based metrological devices will be faster and more accurate in operation. Moreover, the Nb-based Cooper pair electrometer could be coupled to an Nb single Cooper pair qubit which can be beneficial for both, the stability of the qubit and its readout with a large signal-to-noise ratio..

  • PDF