• Title/Summary/Keyword: Single Die

Search Result 196, Processing Time 0.025 seconds

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

Comparison of Single and Sandwich Collagen Gel on the Survival and Metabolism of Rat Hepatocytes Primary Cell Culture (쥐 간세포 일차배양 세포의 생존능과 대사능에 단층과 복층 콜라젠 젤이 미치는 영향의 비교)

  • 정미경;이혜경
    • KSBB Journal
    • /
    • v.11 no.4
    • /
    • pp.453-461
    • /
    • 1996
  • We compared the effects of two different systems of collagen matrix protein application on the survival and the biological functions of cultured primary hepatocytes. The rat liver primary hepatocytes were grown for approximately 40 days in vitro either on single collagen gel or between collagen sandwich gels. The morphological changes were observed for this culture period. While the hepatocytes grown on single gel began to die around at 7 days of culture, the cells grown between collagen gels still maintained their viability and began to die after 15 days. As markers for liver hepatic functions, we determined the biochemical activities of hepatocytes such as the secretions of albumin, fibronectin, fibrinogen, urea, and the reduction of secreted ammonia. We found that the rat hepatocytes cultured between collagen gels maintained fairly good biochemical functions than the hepatocytes cultured on single gel did. Therefore, the application of an extracellular matrix protein, collagen, in sandwich form was confirmed as a better choice for maintaining the functional hepatocytes culture for long term in vitro.

  • PDF

Design of Efficient Flicker Detector for CMOS Image Sensor (CMOS Image sensor 를 위한 효과적인 플리커 검출기 설계)

  • Lee, Pyeong-Woo;Lee, Jeong-Guk;Kim, Chae-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.739-742
    • /
    • 2005
  • In this paper, an efficient detection algorithm for the flicker, which is caused by mismatching between light frequency and exposure time at CMOS image sensor (CIS), is proposed. The flicker detection can be implemented by specific hardware or complex signal processing logic. However it is difficult to implement on single chip image sensor, which has pixel, CDS, ADC, and ISP on a die, because of limited die area. Thus for the flicker detection, the simple algorithm and high accuracy should be achieved on single chip image sensor,. To satisfy these purposes, the proposed algorithm organizes only simple operation, which calculates the subtraction of horizontal luminance mean between continuous two frames. This algorithm was verified with MATLAB and Xilinx FPGA, and it is implemented with Magnachip 0.18 standard cell library. As a result, the accuracy is 95% in average on FPGA emulation and the consumed gate count is about 7,500 gates (@40MHz) for implementation using Magnachip 0.18 process.

  • PDF

Conformation of single polymer molecule in a slot coating flow

  • Lee, Jeong-Yong;Ryu, Bo-Kyung;Lee, Joo-Sung;Jung, Hyun-Wook;Hyun, Jae-Chun
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • To satisfy good mechanical and optical properties of polymer-coated film products, it will be indispensable to elucidate the molecular orientation of polymer chains within coating liquids in coating flows. Using hybridized numerical method between computational fluid dynamics (CFD) and Brownian dynamics (BD) simulations can provide the useful information for the better quality control of coated films. Flexible polymer chains, e.g., ${\lambda}$-DNA molecules here, change their conformation according to the flow strength and the flow type. The molecular conformation within the coated film on the web or substrate is quite different, because the polymer chains experience the complicated flow strength and flow types in flow field. Especially in the slot coating flow, these chains are more extended by the extension-like flow field generated in the free surface curvature just beyond the downstream die region. Also, the polymer chain extension beneath the free surface can be affected by the die geometry, e.g., the coating gap, changing flow field.

Injection Mold Technology of Protein Chip for Point-of-Care (현장진단용 단백질 칩 사출금형기술)

  • Lee, Sung-Hee;Ko, Young-Bae;Lee, Jong-Won;Jung, Hae-Chul;Park, Jae-Hyun;Lee, Ok-Sung
    • Design & Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.74-78
    • /
    • 2012
  • A multi-cavity injection mold system of protein chip for point-of-care with cavity temperature and pressure sensors was proposed in this work. In advance of manufacturing for the multi-cavity injection mold system, a single cavity injection mold system to mold protein chip was considered. Injection molding analysis for the presented system was performed to optimize the process of the molding and suggest guides to design. On the basis of the results for the single cavity system, a multi-cavity injection mold system for protein chip was analyzed, designed and manufactured with cavity temperature and pressure sensors. Results of balanced filling for protein chip models were obtained from the presented mold system.

  • PDF

Interface Bonding of Copper Clad Aluminum Rods by the Direct Extrusion (직접압출에 의한 Cu-Al 층상 복합재료 봉의 계면접합)

  • 김희남;윤여권;강원영;박성훈;이승평
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.437-440
    • /
    • 2000
  • Composite material consists of more than two materials and make various kinds of composite materials by combining different single materials. Copper clad aluminum composite material is composed of Al and Cu, and it has already been put to practical use in Europe because of its economic benefits. This paper presents the interface bonding according to the variation of extrusion ratio and semi-angle die by observing the interface between Cu and Al using metal microscope. By that result, we can predict the conditions of the interface bonding according to the extruding conditions.

  • PDF

Evaluation of Cooling Capability of Hot Press Forming Die with Thermal CFD Simulation (열유동 해석을 통한 핫프레스 포밍 금형의 냉각 성능 평가)

  • Lee, K.;Lee, J.J.;Suh, C.H.
    • Transactions of Materials Processing
    • /
    • v.25 no.4
    • /
    • pp.242-247
    • /
    • 2016
  • CFD simulation with FlowVision® is used to evaluate the capability of cooling channel in hot press forming dies. Two different types of cooling channels, dry drilled and pocket types are considered for comparison. Two different approaches for simulating cooling channel are considered. One is single-phase velocity calculation for coolant only and the other is multiphase thermal and velocity calculation for die, blank and coolant all together. Both approaches show better cooling performance in pocket type cooling channel. Also both approaches show their own effectiveness in designing cooling channel of hot press forming dies.

A method for estimating residual stress development of PCB during thermo-compression bonding process (PCB 열 압착 공정에서 잔류응력 계산을 위한 방법)

  • Lee, Sang-Hyuk;Kim, Sun-Kyung
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.209-213
    • /
    • 2008
  • In this work, we have proposed a method for calculating the residual stress developed during the PCB thermo-compression bonding precess. Residual stress is the most important factor that causes PCB warpage in accordance with the pattern design. In this work, a single-layed double-sided PCB, which is comprised of the dielectric (FR-4) substrate in the middle and copper cladding on the both top and bottom sides, is considered. A reference temperature, where all stress is free, is calculated by comparing the calculated and measured warapge of a PCB of which copper cladding of the top side is removed. Then, the reesidual stress values is calculated for the double-sided PCB.

  • PDF

A numerical study on blow molding for manufacturing PET bottle consisted of single body (손잡이 일체형 PET 용기 제작을 위한 블로우 성형에 대한 수치적 연구)

  • Kim, Jong-Duck;Go, Young-Bae;Kim, Hong-Ryul;Kwon, Chang-Oh
    • Design & Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.22-27
    • /
    • 2008
  • Forming of PET bottle was performed by injection-stretch blow molding. Blow molding is process of contacting the dies with air of materials by pressing. In this paper, the aim was to improve reliability of technical stabilization for the PET bottle that is last productive product and process technology which was able to do maximization by a preform performance enhancement of the uniform thickness that took temperature and a characteristic of materials. Preform design and dies manufacture were conducted using injection blow molding analysis results. Therefore thickness error of 5% for PET bottle can be obtained in this paper.

  • PDF

Study on the 3D Design of Bracket with Automatic Module (자동화 모듈을 활용한 브라켓의 3D설계에 관한 연구)

  • Choi, Kye-Kwang;Kim, Kwang-Hee;Lee, Dong-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1164-1169
    • /
    • 2009
  • In this study, the bracket for car was designed in 3D using Cimatron Die Design, one of the automatic modules. To facilitate the stamping of the product, the layout of the strip was adjusted slightly. The blank layout of the double-width, 2-line, 2-pull out inner carrier was then optimized as a single arrangement. 3D design was completed in 11 processes.