• 제목/요약/키워드: Single Cycle

검색결과 1,045건 처리시간 0.027초

ON SOME PROPERTIES OF A SINGLE CYCLE T-FUNCTION AND EXAMPLES

  • Rhee, Min Surp
    • 충청수학회지
    • /
    • 제23권4호
    • /
    • pp.885-892
    • /
    • 2010
  • In this paper we study the structures and properties of a single cycle T-finction, whose theory has been lately proposed by Klimov and Shamir. Any cryptographic system based on T-functions may be insecure. Some of the TSC-series stream ciphers have been successfully attacked by some attacks. So it is important to analyze every aspect of a single cycle T-function. We study some properties on a single cycle T-function and we show some examples are single cycle T-functions by these properties, whose proof is easier than existing methods.

단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle)

  • 송영승;정해원;윤원재;김용찬
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.

수정된 재생사이클 가스터빈의 설계 및 부분부하 성능해석 (Analysis of Design and Part Load Performance of a Modified Regenerative Cycle Gas Turbine)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.467-472
    • /
    • 2005
  • Characteristics of a Modified regenerative cycle gas turbine has been investigated. In the cycle, the turbine expansion is divided into two parts and the regenerator locates between them. Two types of mechanical design are assumed: two-shaft and single-shaft. In particular, optimal pressure ratio division between the high and low pressure turbines is evaluated for the single shaft configuration. The part load analyses have been carried out with the aid of off-design models. In addition to the general fuel only control, a variable speed control is assumed as the part load operating strategy of the single shaft configuration. Obvious advantage with the alternative cycle is observed in the variable speed operation of the single shaft design.

  • PDF

Single-Cycle 기법을 이용한 포핏밸브형 2-행정기관의 RSSV 형상에 따른 소기효율 측정에 관한 연구 (A Study on the Scavenging Efficiency Evaluation for the RSSV Configuration of 2-Stroke Engine with Popet Valve Type Using Single-Cycle Method)

  • 이진욱;강건용;정용일;이주헌;박정규
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.69-79
    • /
    • 1997
  • This paper deals with the measurement and analysis on the scavenging performance of the oppet-valve type two-stroke engine with different shroud system. The scavenging flow characteristics is investigated by flow visualization under steady condition, in which a dye is introduced into single-cycle method using the difference of specific gravity between two working fluids is used to evaluate the scavenging efficiency and the trapping efficiency. The 90° shroud system was found to be the highest efficiency system through both flow visualization and single-cycle test, as well as the shroud system to generally be efficient for reducing a short-circuiting flow during scavenging process in a two-stoke engine.

  • PDF

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

Use of G gene-deleted single-cycle viral hemorrhagic septicemia virus (VHSV) for delivery of nervous necrosis virus (NNV)-like particles

  • Yang, Jeong In;Kim, Min Sun;Kim, Ki Hong
    • 한국어병학회지
    • /
    • 제34권2호
    • /
    • pp.177-184
    • /
    • 2021
  • Vaccines based on single-cycle viruses that are replication-incompetent due to knockout of replication-related structural gene(s) are more immunogenic than inactivated or subunit vaccines and can be used as delivery vehicles for foreign antigens without concerns on the reverting to virulent forms. The aim of this study was to develop a delivery vehicle for nervous necrosis virus (NNV)-like particles (VLPs) using G gene deleted single-cycle VHSV (rVHSV-𝚫G). Recombinant single-cycle VHSVs carrying NNV capsid protein gene between N and P gene of rVHSV-𝚫G genome (rVHSV-𝚫G-NNVCap) were rescued by reverse genetic technology. The successful expression of NNV capsid protein in cells infected with rVHSV-𝚫G-NNVCap was demonstrated by Western blot analysis, and the production of NNV VLPs in infected cells was confirmed using an electron microscopy. The results suggest that single-cycle VHSVs can be used as a safe delivery vehicle for NNV VLPs, and can be extended to other pathogens for the development of prophylactic vaccines.

단일 공급자 다수 구매자 공급체인에서 공급자주기 (The Cycle Time of the Vendor in a Single-Vendor Multi-Buyers Supply Chain)

  • 장석화
    • 산업경영시스템학회지
    • /
    • 제37권3호
    • /
    • pp.129-138
    • /
    • 2014
  • This paper is to analyze the cycle time of the vendor in a single-vendor multi-buyers supply chain. The vendor is the manufacturer and the buyers are the retailers. The cycle time of the vendor is the elapse time from the beginning time of the production to the beginning time of the next production. The cycle time of the vendor that minimizes the total cost in a supply chain is analyzed. The cost factors are the production setup cost and the inventory holding cost of the vendor, the ordering cost and the inventory holding cost of the retailers. The cycle times of the vendor obtained with the costs of the vendor is compared with those obtained with the costs of the vendor and the retailers. Various numerical examples are tested if the cycle times of the vendor for both methods are the same.

고체 산화물 연료전지의 열사이클 따른 성능 열화 특성 연구 (A Study on Thermal Cycle Characteristics of Solid Oxide Fuel Cell)

  • 김응용;송락현;전광선;신동열;강대갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1312-1314
    • /
    • 1998
  • SOFC system is often subject to thermal cycle condition during normal start/stop, shutdown, and emergence state. Under the thermal cycle condition of heating and cooling, the SOFC components expand or shrink, which produces thermal stress and thermal shock. The SOFC performance is degraded by the thermal factors. To protect SOFC system from the thermal degradation, the optimum thermal condition must be clarified. In this study, to examine the thermal cycle characteristics, we fabricated single cells of planar SOFC with an area of $5{\times}5cm$. The electrolyte and PEN were tested under thermal cycle conditions in the range of$ 2-8^{\circ}C/min$. After thermal cycle test. crack creation of the components were examined using ultraviolet apparatus. No crack in the electrolyte and PEN were observed. The single cell system with alumina frame were also tested under thermal cycle conditions of 2, 3, $4^{\circ}C/min$. The single cell was fractured at the thermal cycle of 3 and $4^{\circ}C/min$ and the optimum condition of the thermal cycle to be found below $2^{\circ}C/min$.

  • PDF

Effect of simulated double cycle welding on HAZ microstructure for HSLA steels

  • El-Kashif, Emad F.;Morsy, Morsy A.
    • Advances in materials Research
    • /
    • 제7권3호
    • /
    • pp.195-201
    • /
    • 2018
  • High Strength low alloy steels containing various levels of C, Nb and Mn were used and for each of which, a simulated double thermal cycle was applied with the same first peak temperature and different second peak temperatures to produce HAZ microstructure corresponding to multi-pass weld. Effect of double cycle second temperature on the microstructure was observed and compared with single cycle results obtained from previous works, it was found that the percentage of martensite austenite constituent (MA) increases by Nb addition for all steels with the same Mn content and the increase in Mn content at the same Nb content shows an increase in MA area fraction as well. MA area fraction obtained for the double cycle is larger than that obtained for the single cycle for all steels used which imply that MA will have great role in the brittle fracture initiation for double cycle and the inter-pass temperature should be controlled for medium and high-carbon Mn steel to avoid large area fraction of MA. The beneficial effects of Niobium obtained in single pass weld were not observed for the double cycle or multi pass welds.

Single Transistor에 의한 전파정류 Technique (A Technique for Full Wave Rectification using a Single Transistor)

  • 이주근;이동근
    • 대한전자공학회논문지
    • /
    • 제15권3호
    • /
    • pp.7-10
    • /
    • 1978
  • 이 논문은 single transistor를 사용하여 정현파를 전파정류하는 한 방법을 검토한다. switching으로 동작되는 inverter에 R-feed back을 하고 최적 parameter를 설정하므로써 도통상태의 반파와 cut-off 상태에서 feed back을 통한 반파를 합성하여 전파정류의 출력을 얻는다. cassette deck의 code재생 system에 이용한 바 효과적이었고, AGC 등에 이용 가능하다.

  • PDF