• Title/Summary/Keyword: Sine Filter

Search Result 57, Processing Time 0.029 seconds

Fingerprint Identification Using the Distribution of Ridge Directions (방향분포를 이용한 지문인식)

  • Kim Ki-Cheol;Choi Seung-Moon;Lee Jung-Moon
    • Journal of Digital Contents Society
    • /
    • v.2 no.2
    • /
    • pp.179-189
    • /
    • 2001
  • This paper aims at faster processing and retrieval in fingerprint identification systems by reducing the amount of preprocessing and the size of the feature vector. The distribution of fingerprint directions is a set of local directions of ridges and furrows in small overlapped blocks in a fingerprint image. It is extracted initially as a set of 8-direction components through the Gabor filter bank. The discontinuous distribution of directions is smoothed to a continuous one and visualized as a direction image. Then the center of the distribution is selected as a reference point. A feature vector is composed of 192 sine values of the ridge angles at 32-equiangular positions with 6 different distances from the reference point in the direction image. Experiments show that the proposed algorithm performs the same level of correct identification as a conventional algorithm does, while speeding up the overall processing significantly by reducing the length of the feature vector.

  • PDF

Efficiency and Power Factor Improvement of Induction Motor Using Single-Phase Back Rectifier (단상 강압 정류기를 이용한 유도전동기의 효율 및 역률 개선)

  • 문상필;이현우;서기영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.22-29
    • /
    • 2002
  • Usually, much harmonics are included and cause harmonic loss of motor, torque pulsation, electro-magnetic noise and shock etc. by switching function of inverter when drive induction motor variableness inside. It applied partial resonant Buck converter and three phase voltage type SPWM inverter circuit to induction motor driving system in this paper that see to solve such problem. Changed operation condition variously to do input current of circuit that propose sine-wave by unit power factor almost and capacitor supplied bringing back to life voltage by power supply arranging properly assistance diode and electric power switching. Power factor and efficiency improved as that minimize variation of input at power supply voltage polarity reverse by that add voltage reversal function. Also, by using output filter, reduced harmonic of output line to line voltage components, and introduce state space analysis and forecast operation of rectifier. Such all items confirmed validity through simulation and an experiment.

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

A GCST-based Digital Image Watermarking Scheme (GCST 기반 디지털 영상 워터마킹 방법)

  • Lee, Juck-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.142-149
    • /
    • 2012
  • Various image transformations can be used to compress images, to reduce noises in images and to extract useful features. Watermarking techniques using DCT and DWT have been a lot of research interest in the spread of multimedia contents. In this paper, Gabor cosine and sine transform considered as human visual filter is applied to embedding and extraction of watermarks for digital images. The proposed transform is used for watermarking with fifteen attacks. Randomly normal distributed noises are used as an embedded watermark. To measure the similarity between the embedded watermark and extracted one, a correlation value is computed and furthermore is compared with that of existing DCT method. Correlation values of extracted watermark are computed with randomly normal distributed noise sequences, and the sequence with the largest correlation value is declared as the embedded watermark. Frequency components are divided into various bands. Experimental results for low frequency and mid-frequency bands have shown that the proposed GCST provides a good watermarking algorithm and its performance is better than DCT.

A single sensor based active reflection control system using FxLMS algorithm (FxLMS를 이용한 단일 센서기반 능동 반향음 제어 시스템)

  • Kim, Jaepil;Ji, Youna;Park, Young cheol;Seo, Young soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • This paper presents an active acoustic-reflection control algorithm based on a single sensor. The proposed algorithm operates in a system comprising a single sensor located nearby the reflective surface and a control transducer mounted on the reflective surface. First, the incident and reflected acoustic signals are separated from the sensor signal, and a control signal is generated using the separated signals. For the signal separation, the proposed algorithm requires the response of the reflection path which is estimated from the acoustic response between an external sound source and the sensor. Finally, the control filter is adjusted using the FxLMS (Filtered-x Least Mean Square) algorithm. To verify the effectiveness of the proposed algorithm, it was implemented in real time using a DSP (Digital Signal Processing) board, and the experimental results obtained in one-dimensional air-acoustic environment show that the reflections of the 1 kHz burst can be reduced by 11.6 dB.

The development of a bluetooth based portable wireless EEG measurement device (블루투스 기반 휴대용 무선 EEG 측정시스템의 개발)

  • Lee, Dong-Hoon;Lee, Chung-Heon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.16-23
    • /
    • 2010
  • Since the interest of a brain science research is increased recently, various devices using brain waves have been developed in the field of brain training game, education application and brain computer interface. In this paper, we have developed a portable EEG measurement and a bluetooth based wireless transmission device measuring brain waves from the frontal lob simply and conveniently. The low brain signals about 10~100${\mu}V$ was amplified into several volts and low pass, high pass and notch filter were designed for eliminating unwanted noise and 60Hz power noise. Also, PIC24F192 microcontroller has been used to convert analog brain signal into digital signal and transmit the signal into personal computer wirelessly. The sampling rate of 1KHz and bluetooth based wireless transmission with 38,400bps were used. The LabVIEW programing was used to receive and monitor the brain signals. The power spectrum of commercial biopac MP100 and that of a developed EEG system was compared for performance verification after the simulation signals of sine waves of $1{\mu}V$, 0~200Hz was inputed and processed by FFT transformation. As a result of comparison, the developed system showed good performance because frequency response of a developed system was similar to that of a commercial biopac MP100 inside the range of 30Hz specially.

Design of Format Conversion Filters for MPEG-4 (MPEG-4를 위한 포맷 변환 필터의 설계)

  • Jo, Nam Ik;Kim, Gi Cheol;Yu, Ha Yeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.637-637
    • /
    • 1997
  • In this paper, format conversion filters are proposed, which have advantages in hardware implementation compared to the ones proposed in MPEG-4 Video Verification Model. since each coefficients of the proposed filters is constrained to have less than two non-zero digits in minimal signed digit representation, multiplication of input and the coefficient can be implemented by a single adder. As a result, the proposed filters have advantages in hardware complexity and speed, compared to the filters which are usually implemented by integer multiplier or carry save adders. Six kinds of filters are proposed in MPEG-4 Video Verification Model for size conversion of 2:1, 4:1, 5:3 and 5:6. We design 5 filters for the same purpose and compare the performance. The remaining one is very simple to implement. For comparing the filtering performance, we first compare the results of sine wave frequency conversion as an indirect but meaningful comparison. Second. We compute the PSNR of the images obtained from the proposed filters and the ones proposed by MPEG, with reference to the images obtained by using double precision arithmetic and high order filter. The results show that the performance of the proposed filters is almost the same as that of the filters proposed by MPEG. In conclusion, the peroformance of the proposed filters is comparable to that of the ones in MPEG-4, while requiring lower hardware complexity and providing high operating speed.