• Title/Summary/Keyword: Simultaneous measurement

Search Result 482, Processing Time 0.031 seconds

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

Detection of IgG and IgM antibodies with ELISA technique in human trichomoniasis (질트리코모나스 환자에서 효소표식 면역검사법을 이용한 혈청 내 항-질트리코모나스 IgG 및 IgM 항체가의 측정)

  • 이미리;신명헌
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.25-30
    • /
    • 1990
  • The direct wet mount examination of vaginal. secretion, widely applied for the diagnosis of Trichcmonas vaginalis infection in woman patients, is rapi4 and economical, however, the sensitivity of this technique is not so high. In this study enzyme-linked immunosorbent assay (ELISA) was employed for the detection of serum anti-T. vaginalis IgG and IsM antibodies from 30 vaginal trichomoniasis patients and 30 non-infected healthy persons. The results were as follows: 1. Serum ELISA-IgG value was $0.37{\pm}0.134(Mean{\pm}S.D.)$ in vaginal trichomoniasis patients and $0.21{\pm}0.054$ in healthy controls(P<0.005), and the sensitivity and specificity of ELISA for serum IgG antibody were 70.0% and 96.7%, respectively. 2. Serum ELISA-IgM value was $0.33{\pm}0.177 (Mean{\pm}S.D.)$ in vaginal trichomonlasls patients and $0.11{\pm}0.051$ in healthy controls (p<0.005), and the sensitivity and specificity of ELISA for serum IsM antibody were 70.0% and 96.7%, respectively. 3, The ELISA-IgG values showed a significant correlation with ELISA-IgM values(r=0.77, p<0.005) , With above results, it is assumed that ELISA is a reliable method for the diagnosis of T vaginalis infection and simultaneous measurement of serum IgG and IgM with this technique is recommended.

  • PDF

Parameter Estimation of Coastal Water Quality Model Using the Inverse Theory (역산이론을 이용한 연안 수질모형의 매개변수 추정)

  • Cho, Hong-Yeon;Cho, Bum-Jun;Jeong, Shin-Taek
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.3
    • /
    • pp.149-157
    • /
    • 2005
  • Typical water quality (WQ) parameters defined in the governing equation of the WQ model are the pollutant loads from atmosphere and watersheds, pollutant release rates from sediment, diffusion coefficient and reaction coefficient etc. The direct measurement of these parameters is very difficult as well as requires high cost. In this study, the pollutant budget equation including these parameters was used to construct the linear simultaneous equations. Based on these equations, the inverse problems were constructed and WQ parameter estimation method minimizing the sum of squared errors between the computed and observed amounts of the mass changes was suggested. WQ parameters, i.e., the atmospheric pollutant loads, sediment release rates, diffusion coefficients and reaction coefficient, were estimated using .this method by utilizing the vertical concentration profile data which has been observed in Cheonsu Bay and Ulsan Port. Values of the estimated parameters show a large temporal variation. However, this technique is persuasive in that the RHS (root mean square) error was less than $5.0\%$ of the observed value ranges and the agreement index was greater than 0.95.

Cardiovascular Neurons Mediating Somatosympathetic Reflex in Rostral Ventrolateral Medulla

  • Goo, Yong-Sook;Kim, Sang-Jeong;Kim, Jun;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.185-197
    • /
    • 1993
  • The rostral ventrolateral medulla (RVLM) includes vasopressor neurons, which transmit activation signals to the intermediolateral nucleus (IML) of the spinal cord, where the preganglionic sympathetic nucleus is located, to raise arterial blood pressure (BP). However, controversy exists as to the possible depressor area in the RVLM and the pathway involved. The present study persued evidence far the location of depressor neurons and the pathway by simultaneously observing changes in BP and the firing rate (FR) of cardiovascular neurons (CVNs) in the RVLM during the somatosympathetic reflex (SSR) elicited by peripheral nerve stimulation, since CVNs are known to contribute to the generation of the sympathetic nerve discharge. In 42 cats, anaesthetized with $\alpha-chloralose$, single unit recording was performed, using carbon filament electrodes inserted into the RVLM, enabling estimation of the post R wave unit histogram (PR-UNlT) and the spike triggered average of sympathetic nerve discharge (STA-SND), allowing identification of CVNs. Antidromic stimulation of spinal $T_2$ segment was followed to determine whether the identified CVN projects axonal endings to the spinal cord (reticulospinal neuron). The sciatic nerve was electrically stimulated at $A\delta-intensity$ (1 mA, 0.1 ms), 1 Hz and C-intensity (10 mA, 0.5 ms), 20 Hz to elicit the depressor, and pressor responses of the SSR, respectively. Simultaneous measurement of CVN firing rate was made. Experimental results are summarized as follows. 1) 20 out of 98 CVNs had axonal projections to the spinal cord and 17 out of 98 CVNs showed FR changes during SSR. 2) Response patterns of FR and BP during SSR were classified into 8 types. 3) These 8 different response patterns could be further classified into those from pressor and depressor neurons. These results demonstrate that some CVNs were identifiable as reticulospinal neurons responding to anti-dromic stimulation and that CVNs operating as depressor neurons as well as pressor neurons exist in the RVLM, both of which are involved with SSR mediation. Therefore, evidence was found that an independent depressor pathway might be involved in the mediation of SSR.

  • PDF

Background Gradient Correction using Excitation Pulse Profile for Fat and $T_2{^*}$ Quantification in 2D Multi-Slice Liver Imaging (불균일 자장 보정 후처리 기법을 이용한 간 영상에서의 지방 및 $T_2{^*}$ 측정)

  • Nam, Yoon-Ho;Kim, Hahn-Sung;Zho, Sang-Young;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.6-15
    • /
    • 2012
  • Purpose : The objective of this study was to develop background gradient correction method using excitation pulse profile compensation for accurate fat and $T_2{^*}$ quantification in the liver. Materials and Methods: In liver imaging using gradient echo, signal decay induced by linear background gradient is weighted by an excitation pulse profile and therefore hinders accurate quantification of $T_2{^*}$and fat. To correct this, a linear background gradient in the slice-selection direction was estimated from a $B_0$ field map and signal decays were corrected using the excitation pulse profile. Improved estimation of fat fraction and $T_2{^*}$ from the corrected data were demonstrated by phantom and in vivo experiments at 3 Tesla magnetic field. Results: After correction, in the phantom experiments, the estimated $T_2{^*}$ and fat fractions were changed close to that of a well-shimmed condition while, for in vivo experiments, the background gradients were estimated to be up to approximately 120 ${\mu}T/m$ with increased homogeneity in $T_2{^*}$ and fat fractions obtained. Conclusion: The background gradient correction method using excitation pulse profile can reduce the effect of macroscopic field inhomogeneity in signal decay and can be applied for simultaneous fat and iron quantification in 2D gradient echo liver imaging.

A Case Study on the Application of Vibration Level Units in the Construction Phase (시공단계의 진동레벨 단위적용에 관한 사례 연구)

  • Choi, Hyung-Bin;Kim, Dong-Yeon
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.86-97
    • /
    • 2012
  • Ground vibration induced by a bench blasting in the construction site should cause the damage to the structure and indirect damage to a human body, and the vibration level is most practical descriptor for regulating the damage to human body and peak particle velocity is the descriptor for direct damage assesment of the structure. Meantime, the vibration level has not been considered for the blasting design but this study is the case that apply not only peak particle velocity but also vibration level on the blasting design. Also, we strongly believe that this study will be helpful for the management in the blasting site which some civil appeal is concerned. Total 232 measurements of both ppv and vibration level was used to estimate the scale distance. When the regulating threshold was ppv 0.3 cm/s and vibration level 75 decibel, the charge per delay to be estimated with vibration level could be recommended by 1.2~1.4 times than it of ppv. So, it is proven that considering vibration level on the blasting design is reasonable for not only prevention of the civil appeals but also effective blasting. Again, the blasting design which follows the law, "Noise and Vibration Control Act" can actually serve good condition to carry much more economical and effective blasting. The instruments used for this study are the SV-1 model, as first instrument in korea which can measure vibration velocity and vibration level at the same time.

Electrochemical and Optical Studies on the Passivation of Nickel (니켈의 부동화에 관한 전기화학적 및 광학적 연구)

  • Dong Jin Kim;Woon-Kie Paik
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.369-377
    • /
    • 1982
  • The technique of combined-measurement of reflectance and ellipsometric parameters was used for studying the anodic film formed on nickel surface in basic solutions. An ellipsometer was automated for transient measurements by way of modulating the plane-polarized light with the Faraday effect. Surface film was formed electrochemically by applying a potential step from the reduction potential range to the passivation range on a polished, high-purity, polycrystalline nickel specimen. From that instant, the changes in the reflectance(r) and the ellipsometric parameters(${\Delta},{\Psi}$) of the surface film were recorded by the automatic ellipsometer. Three exact simultaneous equations including these optical signals, ${\Delta},{\Psi}$ and r were solved numerically with a computer in order to determine the optical properties, n, k, and the thickness, ${\tau}$, of the surface film. From the computed results which showed dependence on pH and time, it was found that passivation of nickel can be effectively attained by surface film thinner than $15{\AA}$ and this passivation film has a small optical absorption coefficient. It seemed that a high pH environment enhances the rate of passivation and is favorable for a denser structure of the surface film. The experimental evidence is in accordance with the hypothesis that the composition of the passive film can be approximated by $Ni(OH)_2$ in the early stage of passivation and that as time passes the composition changes partially toward that of NiO through dehydration.

  • PDF

Impedance-Based Characterization of 2-Dimenisonal Conduction Transports in the LaAlO3/SrxCa1-xTiO3/SrTiO3 systems

  • Choi, Yoo-Jin;Park, Da-Hee;Kim, Eui-Hyun;Park, Chan-Rok;Kwon, Kyeong-Woo;Moon, Seon-Young;Baek, Seung-Hyub;Kim, Jin-Sang;Hwang, Jinha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.171.2-171.2
    • /
    • 2016
  • The 2-dimensiona electron gas (2DEG) layers have opened tremendous interests in the heterooxide interfaces formed between two insulating materials, especially between LaAlO3 and $SrTiO_3$. The 2DEG layers exhibit extremely high mobility and carrier concentrations along with metallic transport phenomena unlike the constituent oxide materials, i.e., $LaAlO_3$ and $SrTiO_3$. The current work inserted artificially the interfacial layer, $Sr_xCa_{1-x}TiO_3$ between $LaAlO_3$ and $SrTiO_3$, with the aim to controlling the 2-dimensional transports. The insertion of the additional materials affect significantly their corresponding electrical transports. Such features have been probed using DC and AC-based characterizations. In particular, impedance spectroscopy was employed as an AC-based characterization tool. Frequency-dependent impedance spectroscopy have been widely applied to a number of electroceramic materials, such as varistors, MLCCs, solid electrolytes, etc. Impedance spectroscopy provides powerful information on the materials system: i) the simultaneous measurement of conductivity and dielectric constants, ii) systematic identification of electrical origins among bulk-, grain boundary-, and electrode-based responses, and iii) the numerical estimation on the uniformity of the electrical origins. Impedance spectroscopy was applied to the $LaAlO_3/Sr_xCa_{1-x}TiO_3/SrTiO_3$ system, in order to understand the 2-dimensional transports in terms of the interfacial design concepts. The 2-dimensional conduction behavior system is analyzed with special emphasis on the underlying mechanisms. Such approach is discussed towards rational optimization of the 2-dimensional nanoelectronic devices.

  • PDF

Effects of Wheelchair Back Support and Ischial Pad on Neck, Trunk Angle and Chest Expansion in Stroke Patients (휠체어 허리 지지대와 궁둥 패드가 뇌졸중 환자의 목, 몸통 각도 및 가슴우리 확장에 미치는 영향)

  • An, Jae-Young;Jeon, Kyung-Soo;Choi, Hye-Jin;Park, Jae-Hong;Kwon, Jeong-Eun;Shin, Ji-Yeon;Sin, Han-Sol;Gwon, Ji-Su;Jeong, Hye-Ji;Park, Shin-Jun
    • Journal of Digital Convergence
    • /
    • v.16 no.8
    • /
    • pp.301-309
    • /
    • 2018
  • The purpose of this study was to investigate the immediate effect of lumbar support and ischial pad on neck, trunk angle and chest expansion for stroke patients using wheelchair. Fifteen stroke patients were measured repeatedly when a lumbar support using(L support), a Ischial pad using(I Pad), a Lumbar support with ischial pad using(L With I), and non using it(Non using). The measurement of the neck and trunk angle was confirmed using a mobile phone camera, and chest expansion was performed using a tapeline. L With I increased significantly in neck and trunk angle and lower chest expansion than non using. This study shows that simultaneous use of lumbar support and ischial pad for stroke patients using wheelchair can increase the neck and trunk angle, chest expansion immediately. Future studies will need to identify more long-term changes by continuing intervention with more subjects.