• Title/Summary/Keyword: Simultaneous fire

Search Result 45, Processing Time 0.025 seconds

A Study on the Evacuation Risk of Simultaneous Fires from Exterior (외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구)

  • Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.48-54
    • /
    • 2012
  • In order to study on the evacuation risk when connate fires caused by vertical fire spread of the exterior occurs, the egress simulations based on the relevant scenarios has carried out. As a result of it, ASET (permitted evacuation time) was reached in between 550 to 650 seconds in entire floors after vertical smoke spread from fire of combustible exteriors. In particular, ASET was 358 seconds in the first floor, 490 seconds in the six floor and 473 seconds in the tenth floor. In addition, five floors of all levels, the 1st floor, the 6th floor and the 28th floor ~30th floor, show RSET (minimum evacuation time) which is bigger than ASET as evacuation risk. This result presents occupants in high rise buildings with more than 15 floors might not be able to egress of them using staircases due to huge population attempting to evacuate simultaneously. Particularly, 699 people in the upper levels by smoke from the first floor are having difficulty escaping this building since ASET on the first floor adjacent to the ignition point was 358 seconds which is relatively reached fast. Considering a prevention method of the fire and smoke spread, architects have to use non-combustible exterior in the building's facade to be required as an active fire protection system.

Non-linear fire-resistance analysis of reinforced concrete beams

  • Bratina, Sebastjan;Planinc, Igor;Saje, Miran;Turk, Goran
    • Structural Engineering and Mechanics
    • /
    • v.16 no.6
    • /
    • pp.695-712
    • /
    • 2003
  • The non-linear structural analysis of reinforced concrete beams in fire consists of three separate steps: (i) The estimation of the rise of surrounding air temperature due to fire; (ii) the determination of the distribution of the temperature within the beam during fire; (iii) the evaluation of the mechanical response due to simultaneous time-dependent thermal and mechanical loads. Steps (ii) and (iii) are dealt with in the present paper. We present a two-step computational procedure where a 2D transient thermal analysis over the cross-sections of beams are made first, followed by mechanical analysis of the structure. Fundamental to the accuracy of the mechanical analysis is a new planar beam finite element. The effects of plasticity in concrete, and plasticity and viscous creep in steel are taken into consideration. The properties of concrete and steel along with the values of their thermal and mechanical parameters are taken according to the European standard ENV 1992-1-2 (1995). The comparison of our numerical and full-scale experimental results shows that the proposed mechanical and 2D thermal computational procedure is capable to describe the actual response of reinforced concrete beam structures to fire.

A Study on the Defense Effectiveness of Surface Ships against diverse Anti-Surface Missile Attack Strategies (대함유도탄 공격유형에 따른 수상함 방어효과도 분석 연구)

  • Kim, Jae Ick;Jung, Young Ran;Kim, Hyun Sil;Kim, Cheol Ho;Yu, Chan Woo
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • Anti-surface missiles have been the most dangerous threat to the surface ships, therefore analyzing the defense effectiveness of surface ships against diverse anti-surface missiles attack strategies is very important to evaluate and anticipate the naval combat ship's abilities in terms of AAW (Anti-Air Warfare). In this paper, we don't study on the defense effectiveness of a ship against a missile, but focus on the defense effectiveness for surface ships against multiple missiles specialized in strategies of anti-surface missiles; ripple fire attack and simultaneous time on target attack (STOT). So, we conduct a variety of monte-carlo simulations with high-fidelity simulators, analyze the measure of defense effectiveness for the key factors of strategies and evaluate the effects and possible interactions of several factors through the analysis of the design of experiment (DOE).

  • PDF

Application of Fuzzy Logic for Predicting of Mine Fire in Underground Coal Mine

  • Danish, Esmatullah;Onder, Mustafa
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.322-334
    • /
    • 2020
  • Background: Spontaneous combustion of coal is one of the factors which causes direct or indirect gas and dust explosion, mine fire, the release of toxic gases, loss of reserve, and loss of miners' life. To avoid these incidents, the prediction of spontaneous combustion is essential. The safety of miner's in the mining field can be assured if the prediction of a coal fire is carried out at an early stage. Method: Adularya Underground Coal Mine which is fully mechanized with longwall mining method was selected as a case study area. The data collected for 2017, by sensors from ten gas monitoring stations were used for the simulation and prediction of a coal fire. In this study, the fuzzy logic model is used because of the uncertainties, nonlinearity, and imprecise variables in the data. For coal fire prediction, CO, O2, N2, and temperature were used as input variables whereas fire intensity was considered as the output variable.The simulation of the model is carried out using the Mamdani inference system and run by the Fuzzy Logic Toolbox in MATLAB. Results: The results showed that the fuzzy logic system is more reliable in predicting fire intensity with respect to uncertainties and nonlinearities of the data. It also indicates that the 1409 and 610/2B gas station points have a greater chance of causing spontaneous combustion and therefore require a precautional measure. Conclusion: The fuzzy logic model shows higher probability in predicting fire intensity with the simultaneous application of many variables compared with Graham's index.

Simultaneous Determination of the Seven Phenylpropanoids in Xanthii Fructus Using a HPLC-PDA and LC-MS

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.24 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • Xanthii Fructus has been traditionally used for the treatment of rhinitis, rheumatoid arthritis, and eczema. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) method was developed and then used for the simultaneous analysis of eight phenylpropanoids in Xanthii Fructus. The analytical column used for this separation was a $SunFire^{TM}$ $C_{18}$ column, maintained at $40^{\circ}C$. The mobile phase used was 1.0% acetic acid in distilled water and 1.0% acetic acid in acetonitrile with gradient elution. For identify of each component, the mass spectrometer (MS) was used a Waters triple quadrupole mass spectrometer requipped with electrospray ionization (ESI) source. The HPLC-PDA method showed good linearity: correlation coefficients were ${\geq}0.9996$. The limits of detection and quantification of the eight compounds were 0.02 - 0.04 and $0.06-0.14{\mu}g/mL$, respectively. The extraction recoveries ranged from 97.51 to 108.67%. The relative standard deviation values of intra- and inter-day precision were 0.06 - 1.55 and 0.09 - 1.68%, respectively. The validated HPLC-PDA method was applied to simultaneously analyse the amounts of eight phenlypropanoids in Xanthii Fructus.

A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP) (소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.29-34
    • /
    • 2012
  • The purpose of this study is to propose an effective operating method of a power generator used by the Emergency Power System in case of a simultaneous fire and of the limitations of the interlock system the power supply from the emergency power generator. On the Emergency Power System with Reserved Fire-fighting Power (RFP), in case of an overload, the collective control Emergency Power System signals the main circuit breaker to shut off the supply to the emergency load, leaving the supply to the firefighting load uninterrupted to the end. The sequential control Emergency Power System signals the firefighting power supply to shut off the fire stage of the emergency load and continues to monitor the power supply. If an overload happens again from increased firefighting load, the sequential control Emergency Power System sends a secondary signal to shut down the second stage of the emergency load.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

Synthesis and Cyclization of Aromatic Polyhydroxyamides. 1. Model Compound Study

  • Kim, Hae-Young;Kim, Myung-Kyoon;Baik, Doo-Hyun;Simon Kantor
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1998.10a
    • /
    • pp.37-40
    • /
    • 1998
  • Aromatic polybenzoxazoles have been known since 1964 as a class of aromatic heterocyclic polymers that exhibit excellent thermal stability. Polyhydroxyamides (PHA), precursor polymers to PBO, can cyclize to farm stable heterocyclic polymers with the simultaneous release of small molecules, which can be expected to act as a fire quencher. (omitted)

  • PDF

The geometry of Sulbasu${\={u}}$tras in Ancient India (고대 인도와 술바수트라스 기하학)

  • Kim, Jong-Myung;Heo, Hae-Ja
    • Journal for History of Mathematics
    • /
    • v.24 no.1
    • /
    • pp.15-29
    • /
    • 2011
  • This study was carrying out research on the geometry of Sulbas${\={u}}$tras as parts of looking for historical roots of oriental mathematics, The Sulbas${\={u}}$tras(rope's rules), a collection of Hindu religious documents, was written between Vedic period(BC 1500~600). The geometry of Sulbas${\={u}}$tras in ancient India was studied to construct or design for sacrificial rite and fire altars. The Sulbas${\={u}}$tras contains not only geometrical contents such as simple statement of plane figures, geometrical constructions for combination and transformation of areas, but also algebraic contents such as Pythagoras theorem and Pythagorean triples, irrational number, simultaneous indeterminate equation and so on. This paper examined the key features of the geometry of Sulbas${\={u}}$tras and the geometry of Sulbas${\={u}}$tras for the construction of the sacrificial rite and the fire altars. Also, in this study we compared geometry developments in ancient India with one of the other ancient civilizations.

Study of the Improvement Method of a Hazardous Materials Classification System for the Introduction in GHS (GHS제도 도입에 따른 위험물 분류체계의 개선방안)

  • Lee, Bong-Woo;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.108-115
    • /
    • 2017
  • This study evaluated a preventive information communication system for the storage, handing, and transportation of hazardous materials according to the hazardous materials safety management law of Korea. At present, the chemical management system has very little information on accident responses due to a problem in the initial response. Therefore, this study was designed to improve the hazardous materials safety management law as an advanced method for simultaneous accident prevention and response, such as GHS system. This can also cause confusion in industry, such as manufacturing and import-export companies, because safety management laws and the GHS system are very different from the hazard classification systems. This study suggests a harmonization plan between the hazardous materials safety management law and the GHS classification system through an analysis of the hazardous materials classification system of major advanced countries.