• Title/Summary/Keyword: Simulation surgery

Search Result 275, Processing Time 0.032 seconds

3D Face Modeling using Face Image

  • Kim, Sanghyuk;Ban, Yuseok;Park, Changhyun;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.10-12
    • /
    • 2015
  • Purpose It has been stated that patient satisfaction is the crucial factor for determining success in plastic surgery. The convergence of medical science and computer vision has made easier to satisfy patients who wants to have plastic surgery. In this paper, we try to apply 3D face modeling in plastic surgical area. Materials and Methods The author introduces a method for accurate 3D face modeling techniques using a statistical model-based 3D face modeling approach in a mirror system. Results We could successfully obtain highly accurate 3D face shape results. Conclusion The method suggested could be used for acquiring 3D face models from 2D face image and the result obtained from this could be effectively used for plastic surgical areas.

Research on Computer-aided and Robotic-assisted Surgery of Fracture Reduction and Bone Deformity Correction under External fixation (외고정법을 이용한 컴퓨터이용 및 로봇지원 골절수술 및 골변형교 정술에 대한 연구)

  • Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.131-134
    • /
    • 2005
  • This paper presents a computer-aided simulation and robotic-assisted execution technology of external fixation method to achieve fracture reduction and deformity correction in long bones. Combining the kinematic analysis with a graphic model of the tibia and the fixator allowed 3D simulation and visualization of the adjustments required to reduce fracture or correct bone deformity as a pre-operative planning tool. The developed robot model provided accurate deformity correction with small residual deformity based on the results of the planning. By incorporating the robot model with image-guided system and computer-aided planning, the integrated system could be useful for computer-aided pre-operative planning and robotic-assisted execution in fracture treatment and bone deformity surgery.

  • PDF

Genioplasty using a simple CAD/CAM (computer-aided design and computer-aided manufacturing) surgical guide

  • Lim, Se-Ho;Kim, Moon-Key;Kang, Sang-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.44.1-44.6
    • /
    • 2015
  • Background: The present study introduces the design and fabrication of a simple surgical guide with which to perform genioplasty. Methods: A three-dimensional reconstruction of the patient's cranio-maxilla region was built, with a dentofacial skeletal model, then derived from CT DICOM data. A surgical simulation was performed on the maxilla and mandible, using three-dimensional cephalometry. We then simulated a full genioplasty, in silico, using the three-dimensional (3D) model of the mandible, according to the final surgical treatment plan. The simulation allowed us to design a surgical guide for genioplasty, which was then computer-rendered and 3D-printed. The manufactured surgical device was ultimately used in an actual genioplasty to guide the osteotomy and to move the cut bone segment to the intended location. Results: We successfully performed the osteotomy, as planned during a genioplasty, using the computer-aided design and computer-aided manufacturing (CAD/CAM) surgical guide that we initially designed and tested using simulated surgery. Conclusions: The surgical guide that we developed proved to be a simple and practical tool with which to assist the surgeon in accurately cutting and removing bone segments, during a genioplasty surgery, as preoperatively planned during 3D surgical simulations.

Dye-Perfused Human Placenta for Simulation in a Microsurgery Laboratory for Plastic Surgeons

  • Laura C. Zambrano-Jerez;Karen D. Diaz-Santamaria;Maria A. Rodriguez-Santos;Diego F. Alarcon-Ariza;Genny L. Melendez-Florez;Monica A. Ramirez-Blanco
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.627-634
    • /
    • 2023
  • In recent decades, a number of simulation models for microsurgical training have been published. The human placenta has received extensive validation in microneurosurgery and is a useful instrument to facilitate learning in microvascular repair techniques as an alternative to using live animals. This study uses a straightforward, step-by-step procedure for instructing the creation of simulators with dynamic flow to characterize the placental vascular tree and assess its relevance for plastic surgery departments. Measurements of the placental vasculature and morphological characterization of 18 placentas were made. After the model was used in a basic microsurgery training laboratory session, a survey was given to nine plastic surgery residents, two microsurgeons, and one hand surgeon. In all divisions, venous diameters were larger than arterial diameters, with minimum diameters of 0.8 and 0.6 mm, respectively. The majority of the participants considered that the model faithfully reproduces a real microsurgical scenario; the consistency of the vessels and their dissection are similar in in vivo tissue. Furthermore, all the participants considered that this model could improve their surgical technique and would propose it for microsurgical training. As some of the model's disadvantages, an abundantly thick adventitia, a thin tunica media, and higher adherence to the underlying tissue were identified. The color-perfused placenta is an excellent tool for microsurgical training in plastic surgery. It can faithfully reproduce a microsurgical scenario, offering an abundance of vasculature with varying sizes similar to tissue in vivo, enhancing technical proficiency, and lowering patient error.

Multiplanar Reformation of CT Scan for Preoperative Staging of Gastric Cancer

  • Kim, Honsoul;Lim, Joon Seok
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.43-45
    • /
    • 2015
  • Recent progress on CT such as multi-detector row CT, oral contrast agents and multiplanar reconstruction have markedly improved the image quality as well as diagnostic performance of gastric cancer. Multiplanar reformatted images at predetermined orientations can be easily performed and embedded into routine CT protocol without increasing medical expense or labor. Currently, many institutions have adopted routine multiplanar reformatted protocols and therefore knowledge on them can improve the diagnostic accuracy of gastric cancer.

Modified Urethral Graciloplasty Cross-Innervated by the Pudendal Nerve for Postprostatectomy Urinary Incontinence: Cadaveric Simulation Surgery and a Clinical Case Report

  • Hisashi Sakuma;Masaki Yazawa;Makoto Hikosaka;Yumiko Uchikawa-Tani;Masayoshi Takayama;Kazuo Kishi
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.578-585
    • /
    • 2023
  • An artificial sphincter implanted in the bulbous urethra to treat severe postprostatectomy urinary incontinence is effective, but embedding-associated complications can occur. We assessed the feasibility, efficacy, and safety of urethral graciloplasty cross-innervated by the pudendal nerve. A simulation surgery on three male fresh cadavers was performed. Both ends of the gracilis muscle were isolated only on its vascular pedicle with proximal end of the obturator nerve severed and transferred to the perineum. We examined whether the gracilis muscle could be wrapped around the bulbous urethra and whether the obturator nerve was long enough to suture with the pudendal nerve. In addition, surgery was performed on a 71-year-old male patient with severe urinary incontinence. The postoperative 12-month outcomes were assessed using a 24-hour pad test and urodynamic study. In all cadaveric simulations, the gracilis muscles could be wrapped around the bulbous urethra in a γ-loop configuration. The length of the obturator nerve was sufficient for neurorrhaphy with the pudendal nerve. In the clinical case, the postoperative course was uneventful. The mean maximum urethral closure pressure and functional profile length increased from 40.7 to 70 cm H2O and from 40.1 to 45.3 mm, respectively. Although urinary incontinence was not completely cured, the patient was able to maintain urinary continence at night. Urethral graciloplasty cross-innervated by the pudendal nerve is effective in raising the urethral pressure and reducing urinary incontinence.

Computer-aided Maxillofacial ablation and reconstruction Surgery (임상가를 위한 특집 1 - 컴퓨터 기반 악골 종양의 절제 및 재건술)

  • Moon, Seong-Yong;Lim, Sung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.52 no.10
    • /
    • pp.596-601
    • /
    • 2014
  • Computer-aided surgery is popular and useful in the field of oral and maxillofacial surgery, because of the possibility of simulation with a high accuracy. In all aspects of surgery, proper planning facilitates more predictable operative results, however before the use of virtual planning, much of this relied on 2-dimensional (2-D) imaging for treatment planning on a 3-dimensional (3-D) object and surgical trial and error. With real-time instrument positioning and clear anatomic identification, a computer-assisted navigation system (CANS) is exceptionally helpful in maxillofacial surgery. These techniques enable performing precise bony ablation and reconstruction, and also decrease surgical time and donor site defect.