• Title/Summary/Keyword: Simulation Output Analysis

Search Result 1,029, Processing Time 0.025 seconds

Design Analysis of Step-down Multilayer Piezoelectric Transformer

  • Hoonbum Shin;Hyungkeun Ahn;Han, Deuk-Young
    • Journal of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.139-144
    • /
    • 2003
  • In this paper, 11 and 13 layered step-down piezoelectric transformers were fabricated and their electrical characteristics have been analyzed for AC-adapter. When the voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, the output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer are derived with an equivalent circuit model. With those expressions, load and frequency characteristics are discussed through the simulations. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the different load and frequency conditions. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage increase s and resonant frequency changes according to the various resistor loads. Output current decreases inversely proportional to the change of loads. Moreover, the measured output voltage and current are well matched with the simulated results obtained from the proposed equivalent circuit model. Furthermore, a new step-down piezoelectric transformer has been suggested to Increase the output power based on a simulation result having a driving piezoelectric vibrator polarized thickness direction.

Manufacture of Real-time Power Simulator for Electric Railway (전기철도용 실시각 급전시뮬레이터 제작)

  • Jang, Dong-Uk;Chung, Sang-Gi;Kim, Hyol-Chul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1473-1479
    • /
    • 2009
  • Recently, the high speed train was operated and then the train system's reliability requirements are growing more and more. The exact prediction simulation is necessary in the design of power feeding system by the increase of railway electrification. In order to develope the AC feeding system analysis technology, real-time power simulator was manufactured. It is composed to eight channels analog input, forty channels analog output and forty-eight channels digital I/O. The size of simulator rack is 19" and the two I/O boards are installed the PXI chassis built into the real time os. The signal I/O is possible through BNC connector. The test results of manufactured simulator are obtained that the error range of analog I/O signal is below 1 % and simulation condition is set to 1 ms and the simulation output of the analog output compares the results of the simulator.

  • PDF

A Hierarchical RAM Simulation Model Framework (계층적 RAM 시뮬레이션 모델 프레임워크)

  • Kim, Hye-Lyeong;Choi, Sang-Yeong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2010
  • In this paper, we propose a hierarchical RAM simulation model framework which are used to analyze the RAM specifications on the concept refinement phase. The hierarchical RAM simulation model framework consists of RAM simulation models, class library and each model's input and output data lists. The hierarchical RAM simulation models are co-operated with 3 kinds of model - type I, II, III. Type I, II models are used to analyze the target operational availability and Type III is used to establish the initial RAM specifications. Each model's input and output data lists are defined by considering each model's purpose of RAM analysis. The class library is arranged with each model's classes for implementing the hierarchical simulation models. The proposed framework may be applied for executing the RAM activities effectively.

Simulation Modeling of Profit Optimization and Output Analysis using R (R을 활용한 이윤 최적화 시뮬레이션 모델링 및 결과 분석)

  • Cho, Min-Ho;Jeon, Yong-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.8
    • /
    • pp.883-888
    • /
    • 2014
  • Simulation is now using in various area as an effective decision analysis tool in complex environment of today. But, There is a focus to the simulation model development and execution better than result analysis. This article will emphasis to the importance of result analysis apart from model development in simulation, and will use R package for profit optimization simulation. R has a various function in statistic analysis and data manipulation, graphic display. So this research can show the value of R as a tool for simulation.

A Reliability Analysis on FDS Pyrolysis Model through Comparing the Room-Corner (ISO 9705) Test (룸 코너 콘 칼로리미터 시험(ISO 9705)과 비교를 통한 FDS 열분해 모델의 신뢰성 분석)

  • Yang, Sung-Jin;Lee, Chang-Deok;Oh, Ji-Eun;Kang, Chan-Yong;Kim, Hag-Beom;Lee, Duck-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.585-593
    • /
    • 2011
  • Actual fire test under a laboratory and fire simulation by using computer are considered into main methodology in order to estimate and predict fire size of railway train. Even if practical fire size could be obtained from the full-model railway car test such as a large scale cone-calorimeter test, it is not always possible and realistic due to that expensive cost and attendant dangers could in no way be negligible. In this point of view, fire simulation analysis method based on the computational fluid dynamics could be proposed as an alternative and it seems to be also efficient and reasonable. However, simulation results have to be verified and validated in accordance with the proper procedure including comparing analysis with the actual fire test. In this paper, fire load and growth aspect was investigated through the room corner test (ISO 9705) for the mock-up model of the actual railway car. Then, it was compared with the output data derived from the simulation by using Pyrolysis Model of the FDS (Fire Dynamics Simulator, by NIST) for the exact same domain and condition corresponding with pre-performed room-corner test. This preliminary verified and validated fire modeling method could enhance the reliability of output data derived from the fire simulation under the similar domain and condition.

  • PDF

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

Frequency Controlled Series Resonant Converter System for Power Supply of Communication Station (통신 기지국 전원용 주파수 제어 직렬 공진형 컨버터 시스템)

  • 지준근;임영하
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.323-328
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for power supply of communication station is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(Parallel Output Series Resonant: POSR) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Langage) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

Analysis of an LCLC Resonant Converter with a Capacitive Output Filter

  • Jafarboland, Mehrdad
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.662-668
    • /
    • 2011
  • This paper presents an analysis of a 4th order LCLC resonant converter with a capacitive output filter using the state-space approach. The analysis of the converter shows that there are four intervals in a half period. In each interval, the state-space equations are obtained. Due to the soft switching of the converter, an exact equation for the Zero Voltage Switching (ZVS) time and the maximum dead time of the inverter switches are presented. The simulation and experimental results obtained from a 10kv, 370w prototype confirm the validity of the theoretical analysis.

Performance Analysis for Small Hydro Power at Existing Water Treatment Facilities (물관련 설비를 이용한 소수력발전 성능분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.134-137
    • /
    • 2008
  • A methodology to evaluate the performance analysis for small hydropower at existing water treatment facilities has been studied. It consists of two main parts; flow duration function which can describe existing water treatment facilities and performance analysis to estimate the output characteristics of small hydro power plants. The output performance characteristics for Mi-ho reservoir, Sum-kang low dam, Sun-cheon sewage treatment plant and Nam-dong purification plant were analyzed, using developed model. According to the simulation results, the predicted data show that the data were in good agreement with measured results. Also, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power at existing water treatment facilities.

  • PDF

Blind modal identification of output-only non-proportionally-damped structures by time-frequency complex independent component analysis

  • Nagarajaiah, Satish;Yang, Yongchao
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.81-97
    • /
    • 2015
  • Recently, a new output-only modal identification method based on time-frequency independent component analysis (ICA) has been developed by the authors and shown to be useful for even highly-damped structures. In many cases, it is of interest to identify the complex modes of structures with non-proportional damping. This study extends the time-frequency ICA based method to a complex ICA formulation for output-only modal identification of non-proportionally-damped structures. The connection is established between complex ICA model and the complex-valued modal expansion with sparse time-frequency representation, thereby blindly separating the measured structural responses into the complex mode matrix and complex-valued modal responses. Numerical simulation on a non-proportionally-damped system, laboratory experiment on a highly-damped three-story frame, and a real-world highly-damped base-isolated structure identification example demonstrate the capability of the time-frequency complex ICA method for identification of structures with complex modes in a straightforward and efficient manner.