• Title/Summary/Keyword: Simplified model

Search Result 2,212, Processing Time 0.032 seconds

A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers (두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

Effect of Rocking Behavior of Isolated Nuclear Structures and Sampling Technique for Isolation-System Properties on Clearance-to-stop (면진 원전구조물의 전도거동과 면진시스템 특성에 대한 샘플링 기법이 정지거리에 미치는 영향)

  • Han, Min Soo;Hong, Kee Jeung;Cho, Sung Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.293-302
    • /
    • 2015
  • ASCE 4 requires that a hard stop be built around the seismic isolation system in nuclear power plants. In order to maintain the function of the isolation system, this hard stop is required to have clearance-to-stop, which should be no less than the 90th-percentile displacements for 150% Design Basis Earthquake (DBE) shaking. Huang et al. calculated clearance-to-stop by using a Latin Hypercube Sampling technique, without considering the rocking behavior of the isolated structure. This paper investigates the effects on estimation of clearance-to-stop due to 1) rocking behavior of the isolated structure and 2) sampling technique for considering the uncertainties of isolation system. This paper explains the simplified analysis model to consider the rocking behavior of the isolated structure, and the input earthquakes recorded at Diablo Canyon in the western United States. In order to more accurately approximate the distribution tail of the horizontal displacement in the isolated structure, a modified Latin Hypercube Sampling technique is proposed, and then this technique was applied to consider the uncertainty of the isolation system. Through the use of this technique, it was found that rocking behavior has no significant effect on horizontal displacement (and thus clearance-to-stop) of the isolated structure, and the modified Latin Hypercube Sampling technique more accurately approximates the distribution tail of the horizontal displacement than the existing Latin Hypercube Sampling technique.

Comparative Analysis of SOC Estimation using EECM and NST in Rechargeable LiCoO2/LiFePO4/LiNiMnCoO2 Cells

  • Lee, Hyun-jun;Park, Joung-hu;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1664-1673
    • /
    • 2016
  • Lithium rechargeable cells are used in many industrial applications, because they have high energy density and high power density. For an effective use of these lithium cells, it is essential to build a reliable battery management system (BMS). Therefore, the state of charge (SOC) estimation is one of the most important techniques used in the BMS. An appropriate modeling of the battery characteristics and an accurate algorithm to correct the modeling errors in accordance with the simplified model are required for practical SOC estimation. In order to implement these issues, this approach presents the comparative analysis of the SOC estimation performance using equivalent electrical circuit modeling (EECM) and noise suppression technique (NST) in three representative $LiCoO_2/LiFePO_4/LiNiMnCoO_2$ cells extensively applied in electric vehicles (EVs), hybrid electric vehicles (HEVs) and energy storage system (ESS) applications. Depending on the difference between some EECMs according to the number of RC-ladders and NST, the SOC estimation performances based on the extended Kalman filter (EKF) algorithm are compared. Additionally, in order to increase the accuracy of the EECM of the $LiFePO_4$ cell, a minor loop trajectory for proper OCV parameterization is applied to the SOC estimation for the comparison of the performances among the compared to SOC estimation performance.

Aeroelastic-aerodynamic analysis and bio-inspired flow sensor design for boundary layer velocity profiles of wind turbine blades with active external flaps

  • Sun, Xiao;Tao, Junliang;Li, Jiale;Dai, Qingli;Yu, Xiong
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.311-328
    • /
    • 2017
  • The characteristics of boundary layers have significant effects on the aerodynamic forces and vibration of the wind turbine blade. The incorporation of active trailing edge flaps (ATEF) into wind turbine blades has been proven as an effective control approach for alleviation of load and vibration. This paper is aimed at investigating the effects of external trailing edge flaps on the flow pattern and velocity distribution within a boundary layer of a NREL 5MW reference wind turbine, as well as designing a new type of velocity sensors for future validation measurements. An aeroelastic-aerodynamic simulation with FAST-AeroDyn code was conducted on the entire wind turbine structure and the modifications were made on turbine blade sections with ATEF. The results of aeroelastic-aerodynamic simulations were combined with the results of two-dimensional computational fluid dynamic simulations. From these, the velocity profile of the boundary layer as well as the thickness variation with time under the influence of a simplified load case was calculated for four different blade-flap combinations (without flap, with $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$ flap). In conjunction with the computational modeling of the characteristics of boundary layers, a bio-inspired hair flow sensor was designed for sensing the boundary flow field surrounding the turbine blades, which ultimately aims to provide real time data to design the control scheme of the flap structure. The sensor element design and performance were analyzed using both theoretical model and finite element method. A prototype sensor element with desired bio-mimicry responses was fabricated and validated, which will be further refined for integration with the turbine blade structures.

Developing a Leadership Scale for University Library Middle Managers (대학도서관 중간관리자의 리더십 척도 개발에 관한 연구)

  • Cho, Sung Won;Lee, Jee Yeon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.52 no.3
    • /
    • pp.91-119
    • /
    • 2018
  • The primary focus of this study was on the development of a leadership scale to measure the leadership capacities of university library middle managers. The study included the following research activities. Firstly, broad and narrow scopes were determined and their corresponding questions were selected to develop a leadership scale of university middle managers by analyzing the previous related research findings. Secondly, the scopes and the questions were revised through the Delphi survey method, Thirdly, a survey was conducted to develop a simplified model of the leadership scale. The research outcomes led to three types of leadership scale of the university library middle manager. This study identified the leadership factors of middle managers in the university libraries. The resulting developed leadership scale should serve as the basic information for the existing middle managers' leadership capacity development.

Compensation for Injury to Publicly Owned Marine Resources : Legal and Economic Aspects (해양 공공자연자원 피해보상의 법.경제적 평가)

  • 표희동;이흥동
    • The Journal of Fisheries Business Administration
    • /
    • v.22 no.2
    • /
    • pp.53-74
    • /
    • 1991
  • Interest on ocean environment has increased with the development of industrialized activities. Public marine resorces are defined broadly to include fish stocks, beaches, marine waters, recreational fishing, biota, waterfowls, shorebirds, seabirds and marine mammals But, it is not easy to analyze compensation for injury to publicly owned marine resources because the claimants do not exist clearly and the economic methodology of damage on public goods is not developed fully. This paper introduces basic idea of welfare economic theory and environmental legislation to the research question : How the economics and law can be applied to the case of damage on publicly owned marine resource. The paper discusses the concepts of willingness to pay (WTP) and willingness to accept (WTA). It is accepted generally that WTA is correct concept of welfare change in the case of damaged public goods. Four methods (compensating variation, equivalent variation, compensating surplus, equivalent surplus of measuring welfare changes are compared. Compensating variation(CV) is the best measure of welfare changes are compared. Compensating variation(CV) is the best measure of welfare changes caused by environmental damage. Vartia (1983) showed CV could be measured from the ordinary demand function using the differential equations. This paper also provides an overview of the emerging U.S. and Korea legal system for compensation for natural resource damages, with particular emphasis on U.S. legal system under Comprehensive Environmen-tal Response Compensation and Liability Act (CERCLA). These regulations are to include two different types of standardized procedures for assessing natural resources injury : Type A or simplified assessment techniques for small releases ; and Type B protocols that would include detailed and extensive assessment methodologies for major releases. Type A procedures are specified by Natural Resources Damage Assessment Model for Coastal and Marine Environment (NRDAM/CME) of the U.S. CERCLA provides a legal 'legitimization for the use of economic-based nonmarket valuation in the courts and have introduced appropriate and accurate nonmarket valuation methods based on willingness to-pay for damage assessment. By briefly reviewing economic theory and environmental legislation, we hope to help provide a better understanding of the compensation process and the economics of publicly owned marine resources in the U.S. and to integrate the economics and law of natural resources valuation into a single comprehensive package in Korea.

  • PDF

Comparing the Performance of Three Severity Scoring Systems for ICU Patients: APACHE III, SAPS II, MPM II (중환자 중증도 평가도구의 타당도 평가 - APACHE III, SAPS II, MPM II)

  • Kwon, Young-Dae;Hwang, Jeong-Hae;Kim, Eun-Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.3
    • /
    • pp.276-282
    • /
    • 2005
  • Objectives : To evaluate the predictive validity of three scoring systems; the acute physiology and chronic health evaluation(APACHE) III, simplified acute physiology score(SAPS) II, and mortality probability model(MPM) II systems in critically ill patients. Methods : A concurrent and retrospective study conducted by collecting data on consecutive patients admitted to the intensive care unit(ICU) including surgical, medical and coronary care unit between January 1, 2004, and March 31, 2004. Data were collected on 348 patients consecutively admitted to the ICU(aged 16 years or older, no transfer, ICU stay at least 8 hours). Three models were analyzed using logistic regression. Discrimination was assessed using receiver operating characteristic(ROC) curves, sensitivity, specificity, and correct classification rate. Calibration was assessed using the Lemeshow-Hosmer goodness of fit H-statistic. Results : For the APACHE III, SAPS II and MPM II systems, the area under the receiver operating characterist ic(ROC) curves were 0.981, 0.978, and 0.941 respectively. With a predicted risk of 0.5, the sensitivities for the APACHE III, SAPS II, and MPM II systems were 81.1, 79.2 and 71.7%, the specificities 98.3, 98.6, and 98.3%, and the correct classification rates 95.7, 95.7, and 94.3%, respectively. The SAPS II and APACHE III systems showed good calibrations(chi-squared H=2.5838 p=0.9577 for SAPS II, and chi-squared H=4.3761 p=0.8217 for APACHE III). Conclusions : The APACHE III and SAPS II systems have excellent powers of mortality prediction, and calibration, and can be useful tools for the quality assessment of intensive care units(ICUs).

Analysis of Magnetic Fields Induced by Line Currents using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.141-145
    • /
    • 2006
  • The line current problem(2-dimensional space : point source) is not easy to analyze the magnetic field using the standard finite element method(FEM), such as overhead trolley line or transmission line. To supplement such a defect this paper is proposed the coupling scheme of analytical solution and FEM. In analysis of the magnetic field using the standard FEM. If the current region is a relatively small compared to the whole region. Therefore the current region must be finely divided using a large number of elements. And the large number of elements increase the number of unknown variables and the use of computer memories. In this paper, an analytical solution is suggested to supplement this weak points. When source is line current and the part of interest is far from line current, the analytical solution can be coupling with FEM at the boundary. Analytical solution can be described by the multiplication of two functions. One is power function of radius, the other is a trigonometric function of angle in the cylindrical coordinate system. There are integral constants of two types which can be established by fourier series expansion. Also fourier series is represented as the factor to apply the continuity of the magnetic vector potential and magnetic field intensity with tangential component at the boundary. To verify the proposed algorithm, we chose simplified model existing magnetic material in FE region. The results are compared with standard FE solution. And it is good agreed by increasing harmonic order.

Exaggerated Cartooning using a Reference Image (참조 이미지를 이용한 과장된 카투닝)

  • Han, Myoung-Hun;Seo, Sang-Hyun;Ryoo, Seung-Taek;Yoon, Kyung-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • This paper proposes the method of image cartooning, that makes cartoon-like images of a target, using reference images. We deform a target image using pre-defined reference images. For this deformation, we extract feature points from the target image by Active Appearance Model(AAM) and apply the warping method to the target using feature points of target and feature points of reference image as a basis of warping function. We create simplified cartoon-like images by abstraction of the deformed target image and drawing of edges and quantization of luminance of the abstracted image. Two main concept of cartoon(exaggeration and simplification) is inhered in this method when we use a exaggerated cartoon image as a reference image. It is possible for this method to create various results by control of warping and change of reference image.

A Study on the Fundamental Cause of Stall Stagnation Phenomena in Surges in Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.119-137
    • /
    • 2017
  • Although the stall stagnation phenomena have often been experienced in site and also analytically in numerical experiments in surges in systems of compressors and flow paths, the fundamental causes have not been identified yet. In order to clarify the situations, behaviours of infinitesimal disturbance waves superposed on a main flow were studied in a simplified one-dimensional flow model. A ratio of the amplifying rate of the system instability to the characteristic slope of the compressor element was surveyed as the instability enhancement factor. Numerical calculations have shown the following tendency of the factor. In the situation where both the sectional area ratio and the length ratio of the delivery flow-path to the suction duct are sufficiently large, the enhancement factors are greater in magnitude, which means occurrence of ordinary deep surges. However, in the situation where the area ratio and/or the length ratio is relatively smaller, the enhancement factor tends to lessen significantly, which situation tends to suppress deep surges for the same value of the characteristic slope. It could result in the stall stagnation condition. In the domain of area ratio vs. length ratio of the delivery duct to the suction duct, contour-lines of the enhancement factor behave qualitatively similar to those of the stall stagnation boundaries of a fan analytically obtained, suggesting that a certain range of the enhancement factor values could specify the stagnation occurrence. The significant decreases in the factors are observed to accompany appearances of phase lags and travelling waves in the wave motions, which macroscopically suggests breaking down of the complete surge actions of filling and emptying of the air in the delivery duct. The strength of the action is deeply related with acoustic interferences and is evaluated in terms of the volume-modified reduced resonance frequency proposed by the author. These observations have shown the fundamental cause and the sequence of the stall stagnation in principle.