• 제목/요약/키워드: Simple Pulsed Power

검색결과 27건 처리시간 0.028초

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

전력시스템을 위한 Active Damping Device (An Active Damping Device for a Distributed Power System)

  • 나재두
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.116-121
    • /
    • 2009
  • Distributed power systems (DPSs) has been widely used various industrial/military applications due to their various advantages. Furthermore, the "All electric" concept, in conjunction with DC DPS, appears to be more advanced and mature in the AEV(All-Electric Vehicular) industry. Generally, AEV carry many loads with varied functions. However, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and a simple adaptive controller is proposed as a active damping device to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. In addition, the proposed control approach has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. The control algorithm has been implemented on a TMS320F2812 Digital Signal Processor (DSP). Simulation and experimental results are presented which verify the proposed control principle and demonstrate the practicality of the circuit topology.

IGBT 스택을 이용한 Marx Generator 구현 (Marx Generator Implementation Using IGBT Stack)

  • 김종현;민병덕;김종수;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.507-510
    • /
    • 2005
  • High voltage pulse power supply using Marx generator and solid-state switches is proposed in this study. The Marx generator is composed of 12 stages and each stage is made of IGBT stack, two diode stacks, and capacitor. To charge the capacitors of each stage in parallel, inductive charging method is used and this method results in high efficiency and high repetition rates. It can generate the pulse voltage with the following parameters: Voltage: up to 120kv Rising time: sub ${\mu}S$ Pulse width: up to $10{\mu}S$, Pulse repetition rate: 1000pps The proposed pulsed power generator uses IGBT stack with a simple driver and has modular design. So this system structure gives compactness and easiness to implement total system. Some experimental results are included to verify the system performances in this paper.

  • PDF

고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner (A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control)

  • 나재두
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.

고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가 (Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision)

  • 김흥수;김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권8호
    • /
    • pp.1055-1062
    • /
    • 2001
  • 본 연구에서는 1KHz 부근의 펄스 반복율을 가지는 경제적이고 컴팩트한 펄스형 $CO_2$ 레이저의 개발에 관해서 기술하였다. 고압 고주파 펄스 변압기와 수 십 KHz의 스위칭에 적합한 IGBT를 사용한 고압 펄스전원 장치를 레이저 공진기에 접목시켜 새로운 방식의 고반복 $CO_2$ 레이저 장치를 개발하였다. 전원장치에 사용된 2개의 IGBT를 정밀하게 제어하기 위해서 제어부에는 PIC 마이크로프로세서가 사용되었고 공진기는 수냉방식의 저속축류형으로 제작되었다. 완성된 장치의 펄스 반복율과 동작압력 그리고 레이저 매질 가스의 혼합비의 변화에 따른 레이저빔의 출력 특성실험을 통하여 가스 배압비 $CO_2$$N_2$:He = 1:9:15펄스 반복율 700 Hz, 동작압력 15 Torr에서 최대 레이저 출력 약 20.5 W, 최대 효율 약 8%를 달성하였다.

  • PDF

IGBT를 이용한 고반복 펄스형 $CO_2$ 레이저 개발에 관한 연구 (A Study on the High Repetition Rate Pulsed $CO_2$ Laser Using IGBT)

  • 정현주;김도완;이동훈;윤성호;이유수;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1072-1074
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 kHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2:N_2$:He = 1.3:10, 1:1.5:5 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average output was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2:N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

An Adaptive Narrowband Interference Excision Filter with Low Signal Loss for GPS Receivers

  • Shin, Mi-Young;Park, Chan-Sik;Lee, Ho-Keun;Lee, Dae-Yearl;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1234-1238
    • /
    • 2005
  • As the low power GPS signal is susceptible to interference, interference can seriously degrade the performance of GPS receiver. This paper designs a ANIEF(Adaptive Narrowband Interference Excision in Frequency domain) filter that removes narrow band interferences with low signal loss. This filter uses the pre-correlation technique and attempts to filter out the interference in the frequency domain. The interference excision performance of the designed filter is evaluated for various interferences using the ANIEF filter inserted GPS software receiver and the interference generator. Interferences considered in this paper are single-tone CWI(Continuous Wave Interference), multi-tones CWI, pulsed CWI, and swept CWI. The narrowband interference excision filter in frequency domain is very effective against various interferences and the strong interference with a simple structure. However, the signal power loss is unavoidable while transforming. In this paper, the hamming window and overlap technique are adopted to reduce the signal power loss. Finally, the interference excision performance and the reduced signal power loss of the ANIEF filter are shown.

  • PDF

시뮬레이션을 통한 레이저 융삭 추진의 우주 쓰레기 제거 응용 가능성 연구 (Research on Applicability of Laser Ablation Propulsion to Space Debris Removal by Simulations)

  • 유성문;이승민
    • 한국군사과학기술학회지
    • /
    • 제25권2호
    • /
    • pp.169-176
    • /
    • 2022
  • Laser ablation propulsion(LAP) is the method to create impulse by laser ablation. It can be used to deorbit the space debris(SD), as its long-range property and versatility on any material. In this paper, we find out several requirements of the LAP system(LAPS) to deorbit the SD by simple numerical calculations of the SD orbit and laser beam flux. As a result, minimum operable altitude angle turned out to be a crucial variable to the LAPS. Moreover, if minimum operable altitude angle is 10°, and if the minimum distance between the LAPS and the SD is below 450 km, 1 m/s2 is sufficient to deorbit the SD by once. With 18 kJ/3 ns pulsed laser and cube shaped 100 kg SD, 1 m/s2 acceleration can be achieved by increasing the pulse repetition rate over 34~53 Hz, depending on the size of the SD. This capability could compare with the conceptual design of the Japan Establishment for a Power-laser Community Harvest(J-EPoCH) facility, which include 8 kJ, 5 PW@100 Hz laser.

고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구 (Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge)

  • 정경재;이석근;당정증;최길환;황용석;김철영;박영준
    • 지질공학
    • /
    • 제23권1호
    • /
    • pp.29-36
    • /
    • 2013
  • 스크린 공막힘에 의하여 채수량이 감소된 지하수 관정은 여러 방법을 통하여 재생시켜주면 지하수 채수량을 개선시켜 관정의 수명을 연장할 수 있다. 본 논문에서는 화약이나 압축 유체를 사용하는 기존의 공막힘 재생기술을 대신할 수 있는 고전압 펄스 방전에 의한 지하수 관정 스크린 공막힘의 재생법에 대하여 연구하였다. 본 기술은 수중에 삽입된 전극에 순간적으로 고전압의 전기에너지를 주입하여 이 때 전극 사이에서 발생하는 고온, 고압의 플라즈마의 팽창력에 의하여 발생하는 수중 충격파를 이용하는 기술로, 기존 기술 대비 취급이 용이하며 구조가 간단하고 충격압의 크기 조절이 용이하다는 장점을 갖는다. 본 연구에서는 축전기 방전형 펄스 발생장치를 사용하여 약 200 J의 전기에너지를 수중에 삽입된 전극에 순간적으로 주입함으로써 전극으로부터 6 cm 떨어진 곳에서 약 10.7MPa의 수중 충격압을 얻었다. 이 충격압의 크기는 축전기의 충전 전압을 바꿔줌으로써 손쉽게 조절이 가능하였으며, 다양한 전압에서의 실험을 통하여 방전 전류의 첨두치와 선형적인 관계를 갖고 있음을 알았다. 또한 지하수 관정에 사용되는 스크린과 유사한 시료에 대한 모의실험을 통하여 이 기술을 이용한 지하수 관정의 세척 가능성을 확인하였다.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF