• Title/Summary/Keyword: SimTBS

Search Result 5, Processing Time 0.02 seconds

SimTBS: Simulator For GPGPU Thread Block Scheduling (SimTBS: GPGPU 스레드블록 스케줄링 시뮬레이터)

  • Cho, Kyung-Woon;Bahn, Hyokyung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.87-92
    • /
    • 2020
  • Although GPGPU (General-Purpose GPU) can maximize performance by parallelizing a task with tens of thousands of threads, those threads are internally grouped into a thread block, which is a base unit for processing and resource allocation. A thread block scheduler is a specialized hardware gadget whose role is to allocate thread blocks to GPGPU processing hardware in a round-robin manner. However, round-robin is a sequential allocation policy and is not optimized for GPGPU resource utilization. In this paper, we propose a thread block scheduler model which can analyze and quantify performances for various thread block scheduling policies. Experiment results from the implemented simulator of our model show that the legacy hardware thread block scheduling does not behave well when workload becomes heavy.

Effects of Tea Beverages on Cadmium Accumulation and Excretion in Rats Given Cadmium (차 음료가 카드뮴 섭취 흰쥐의 카드뮴 축적과 배설에 미치는 영향)

  • Kim, Tae-Kyung;Park, Bum-Ho;Lee, Sang-Il;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.161-168
    • /
    • 2008
  • The effects tea beverages (TBs) prepared from powdered green tea (Gt), oolong tea (Ot), black tea (Bt), or pure tea (Pt) with lemon, orange, grenadine etc on cadmium toxicity in rats were investigated Sensory evaluations of the TBs are better than those of each water extracted teas. Cadmium (50 ppm) was administered to experimental rats fed a basic diet, or a diet with various TBs (15% w/v), for 5 weeks. Although body weight gains, feed intakes, and fecal weights in all Cd-treated groups were lower than those in the normal control group (NC), feed efficiency ratio, urine volumes, liver weights, and kidney weights did not differ significantly between groups. The serum ALT and AST levels in the Cd-treated control group (Cd-Co) were higher than those in the NC animals. Serum ALT and AST levels in all Cd-treated rats fed TB-supplemented diets were lower than in animals of the Cd-Co group. Tibia and femur weights in Cd-Co animals were lower than those in NC rats. Tibia and femur weights in Cd-treated rats fed TB-supplemented diets were higher than those in Cd-Co animals. There were no between-group differences in tibia lengths; animals in the NC and TB-supplemented diet groups showed femur lengths longer than those of Cd-Co rats. Although the contents of crude ash and cadmium in the femurs of Cd-Co mts was markedly higher than in the femurs of NC animals, the cadmium content in femurs of Cd-Co rats was significantly lower than that in the femurs of NC animals. The changes in mineral levels caused by Cd administration were alleviated by every TB-supplemented diet tested Whereas fecal calcium excretion by Cd-Co animals was significantly higher than that of NC rats, calcium excretion by Cd-treated rats fed TB-supplemented diets was significantly lower than that of Cd-Co animals. Fecal cadmium excretion by all Cd-treated rats fed TB-supplemented diets was significantly higher than that of Cd-Co animals. In conclusion, this study provides experimental evidence that various TBs may regulate cadmium-induced organ toxicity by reducing cadmium accumulation in tissues through the mechanism of increasing the fecal excretion of cadmium.

EFFECTS OF COLLAGENASE AND ESTERASE ON DENTIN BOND STRENGTH AND NANOLEAKAGE (Collagenase와 esterase가 상아질 접착강도와 nanoleakage에 미치는 영향)

  • Jung, Young-Jung;Hahn, Se-Hyun;Kim, Chong-Chul;Lee, Sang-Hoon;Kim, Jung-Wook;Kim, Young-Jae;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.389-398
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of collagenase and esterase on dentin bond strength and nanoleakage. Resin composites were bonded to occlusal dentin of premolars with Single Bond 2(SB) and Clearfil SE Bond(SE). After the microtensile specimens were prepared and stored in PBS for 24 hours(I) or, PBS(II), collagenase(III), esterase(IV) solution for 4 weeks, the specimens were stained with silver nitrate solution. Microtensile bond strength(${\mu}TBS$) and silver penetration area were measured and, the results were as follows: 1. For group II, III, and IV, the bond strengths of SB were lower than those of SB(p<0.05). The bond strengths of SB II, III, and IV were lower than that of SB I(p<0.05). There was no difference among the bond strengths of SE $I{\sim}IV$ groups(p>0.05). 2. Silver penetration areas of SB were higher than those of SE for all storage groups(p<0.05). In SB and SE groups, there was no significant difference of silver penetration area among $I{\sim}IV$ groups(p>0.05). 3. SE I, II, and III showed inverse relationship between the bond strengths and the silver penetration areas(p<0.05).

  • PDF

Analysis of Heat Transfer considering thickness of Thermal Barrier Coating (열차폐 코팅 두께를 고려한 핀틀의 열전달 해석)

  • Jang, Han Na;Lee, Ji Hoon;Kwak, Jae Su;Cho, Jin Yeon;Kim, Jae Hoon;Ko, JunBok;Heo, Jun-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.392-394
    • /
    • 2017
  • In this study, the surface heat transfer coefficient of the 3D model of a thruster regulator in the high temperature and high pressure environment was estimated using the CFD. The thermal barrier coating (TBC) on the surface of the thruster regulator was modeled and the effect of the thickness of the TBC on the temperature of the thruster regulator was investigated. The thickness of the TBC was varied from $100{\mu}m$ to $500{\mu}m$. Results showed that the temperature of the surface and the inside the thruster regulator was lower for the thicker TBS case.

  • PDF

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.