• Title/Summary/Keyword: Sim Power System

Search Result 797, Processing Time 0.033 seconds

The Modernization of Automatic Control facilities of Hydro Power Plant (수력발전소 자동제어설비의 현대화)

  • Kwon, O-Geuk;Kwon, Young-June;Song, Young-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

A study on AC 220V common power supply system using large area DSC module with Ag grid (대면적 Ag 그리드 DSC 모듈을 활용한 AC 220V 상용 전원장치에 대한 연구)

  • Kim, Hee-Je;Seo, Hyun-Woong;Kim, Mi-Jeong;Hong, Ji-Tae;Sim, Ji-Young;Lee, Sang-Mok;Kim, Ho-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.254-256
    • /
    • 2007
  • The Solar energy is either used as a solar thermal energy or converted to electrical power through power conversion system. The latter method is defined as a solar cell changing the solar energy into the direct electric energy or power conversion that convert the dc power into ac power.For the solar cell to be a practical alternative energy, the study should be focused not only on the solar cell ,but also the power conversion system for common power source. In this study, we get the suitable power to common load ,using Ag Grid DSC(Dye-sensitized solar cell). Our purpose is to achieve the common solar cell power generation system ,using converter and PWM(Pulse width modulation) inverter system controled by DSP.

  • PDF

Sputtering Technique of Magnesium Oxide Thin Film for Plasma Display Panel Applications

  • Choi Young-Wook;Kim Jee-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.110-113
    • /
    • 2006
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The power supply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of $10\sim50$ kHz and $10\sim60%$, respectively. The deposition rate increased with rising incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW. This result shows higher deposition rate than any other previous work involving reactive sputtering in oxide mode. The thickness uniformities over the entire substrate area of $982mm{\times}563mm$ were observed at the processing pressure of $2.8\sim9.5$ mTorr. The thickness distribution was improved at lower pressure. This technique is proposed for application to a high through-put sputtering system for plasma display panels.

A Study of on a Power Control System for a Solar-Electric Vehicle (태양광-전기자동차의 동력제어시스템에 관한 연구)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.3
    • /
    • pp.70-76
    • /
    • 2014
  • The intensity of sunlight becomes lower when weather conditions change, which affects whether a solar-electric vehicle can be driven on a shady road. The power delivered by solar cells can be vary depending on the amount of shade. As a result, the battery system is often used to compensate for variations in the power delivered by solar cells. Therefore, studies of power control systems for solar-electric vehicles are required. In this paper, mathematical models for such a power control system are studied and important variables are considered. Simulation and test results show that the mathematical model and actual designs developed here would be effective when used with solar-electric vehicles.

A study on operating properties of superconducting fault current limiter in the line-to-line fault (선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

A study on the eddy current losses on the high-Tc superconducting power cable system

  • Song M.K.;Lee S.J.;Jang H.M.;Sim K.D.;Cho J.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.32-36
    • /
    • 2005
  • The structure of a high-Tc superconducting power cable system is composed of these parts; (from the outer section) a liquid nitrogen cryostat, a vacuum cryostat, multi-layer high-Tc superconducting cable cores and a stabilizer and both cryostats during the stable operating period of the high-Tc superconducting power cable system are calculated by the numerical method. And the optimal conditions of the stabilizer and both cryostats, that minimize the eddy current losses, are derived from the analyzed results. The optimal results can be applied to the design and manufacture of the high-Tc superconducting power cable system.

Operation Characteristics of Pilot-Scale Gasification System for Coal Syngas Production (석탄 합성가스 제조를 위한 pilot급 가스화 시스템 운전특성)

  • Chung, Seok-Woo;Jung, Woo-Hyun;Lee, Seung-Jong;Yun, Yong-Seung
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.90-97
    • /
    • 2007
  • Gasification has been regarded as a very important technology to decrease environmental pollution and to obtain higher efficiency. The coal gasification process converts carbon containing coal into a syngas, composed primarily of CO and $H_2$. And the coal syngas can be used as a source for power generation or chemical material production. This paper illustrates the opeartion characteristics and results of pilot-scale coal syngas production facilities. The entrained-bed pilot scale coal gasifier was operated normally in the temperature range of $1,300{\sim}1,400^{\circ}C,\;2{\sim}3kg/cm^2$ pressure. And Indonesian KPC coal produced syngas that has a composition of $46{\sim}54%\;CO,\;20{\sim}26%\;H_2,\;and\;5{\sim}8%\;CO_2$.

  • PDF

Operation Characteristics of Pilot-Scale Gasification System for Coal Syngas Production (석탄 합성가스 제조를 위한 pilot급 가스화 시스템 운전특성)

  • Chung, Seok-Woo;Jung, Woo-Hyun;Lee, Seung-Jong;Yun, Yong-Seung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.429-432
    • /
    • 2007
  • Gasification has been regarded as a very important technology to decrease environmental pollution and to obtain higher efficiency, The coal gasification process converts carbon containing coal into a syngas, composed primarily of CO and $H_2$. And the coal syngas can be used as a source for power generation or chemical material production. This paper illustrates the operation characteristics and results of pilot-scale coal syngas production facilities. The entrained-bed pilot scale coal gasifier was operated normally in the temperature range of $1,300{\sim}1,400^{\cdot}C$, $2{\sim}3kg/cm^2$ pressure. And Indonesian KPC coal produced syngas that has a composition of $46{\sim}54$% CO, $20{\sim}26$% $H_2$, and $5{\sim}8$% $CO_2$.

  • PDF

A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable (초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구)

  • Kim, Jae-Ho;Park, Min-Won;Sim, Ki-Deok;Cho, Jeon-Wook;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF