• 제목/요약/키워드: Silver ion sensor

검색결과 15건 처리시간 0.021초

실험계획에 기반한 수돗물 성분(Chloride and Sulfate Ions)의 구조재료 부식 영향성 고찰 (Effects of Chloride and Sulfate Ions on Corrosion Behaviors of Structural Materials Based on Design of Experiment)

  • 임동인;노흥수;권혁준;박승렬;조만식;이두열
    • Corrosion Science and Technology
    • /
    • 제22권3호
    • /
    • pp.201-213
    • /
    • 2023
  • Corrosion management of an aircraft and its engine relies on rinsing and cleaning using tap water. Few studies have reported effects of tap water species on corrosion behaviors of structural materials. In this study, a series of experiments were conducted based on the design of experiment. Solutions with different levels of chloride and sulfate ions were prepared using a full factorial design. Two structural materials (aluminum alloy and steel) were used for an alternate immersion test. Weight loss was then measured. In addition, a silver specimen was utilized as a sensor for chloride deposition measurement. The silver specimen was examined using the electrochemical reduction method, XPS, and SEM-EDS. Surface analysis revealed that levels of chloride and sulfate ions were sufficient for the formation of silver chloride and silver surface. Statistical analysis of weight loss and chloride deposition rate showed significant differences in measured values. Concentration of chloride ions greatly affected corrosion behaviors of structural materials. Sulfate ion hindered the adsorption reaction. These results emphasize the importance of controlling ion concentration of tap water used for cleaning and rinsing an aircraft.

Synthesis and Binding Properties of 1,3,5-Tris(2-arylthiomethyl)mesitylene: A Selective Ag (I) Ionophore

  • Kim, Hong-Seok;Bae, Seon-Yun;Kim, Ki-Soo;Choi, Jun-Hyeak;Choi, Heung-Jin;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.417-421
    • /
    • 2008
  • The efficient synthesis of four mesitylene-based receptors 1-4 and their potentiometric response characteristics to alkali metal, alkaline earth metal, and transition metal ions, under various pH conditions are outlined. Receptor 1-based electrode exhibited more sensitive response to Ag+ ion (49 mV/decade of range from 10-6 to 10-2 M) than the 2-based electrode (47 mV/decade of range from 3 ´ 10-5 to 10-2 M), while the 3- and 4-based ones revealed sub-Nernstian below 40 mV/pAg+. All electrodes showed substantial responses to Ag+ ion under acidic condition, but there was almost nil-response to other transition metal ions (Fe2+, Co2+, Zn2+, Ni2+, Pb2+, Cd2+, Cu2+ and Hg2+). The association constant of receptor 1 toward Ag+ ion, measured by 1H NMR titration, showed the largest value (200 M-1) among the tested receptors. The results were interpreted with semi empirically-modeled structures.

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권10호
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

인쇄공정으로 제조된 저항형 습도센서의 감습특성에 대한 전극패턴의 영향 연구 (The Effect of Electrode Pattern on the Humidity-sensing Properties of the Resistive Humidity Sensor Based on All-printing Process)

  • 안희용;공명선
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.169-176
    • /
    • 2012
  • 저항형 습도센서의 개발을 위하여 스크린 인쇄방법으로 glass epoxy(GE) 기재 위에 핑거의 수와 그 사이의 간격이 다른 여러 가지 바이트형의 금 전극을 제조하였다. 전극의 기본적인 구조는 핑거 수가 3, 4 및 5를 가지며 간격은 각각 310과 460 ${\mu}m$이다. 전극은 처음에 은 나노 페이스트로 전극 패턴을 인쇄하고 연속적으로 Cu, Ni 및 Au를 무전해 도금을 진행하여 제조하였다. 감습성 고분자 전해질은 [2-(methacryloyloxy)ethyl] dimethyl benzyl ammonium chloride(MDBAC)과 methyl methacrylate(MMA)의 공중합체를 사용하였으며 스크린 인쇄 방법으로 Au 전극/GE 기재 위에 인쇄하였다. 이렇게 제조된 습도 센서의 20-95%RH 영역의 상대습도 대 로그 임피던스 그래프에서 좋은 직선성을 보여주었으며 히스테리시스는 1.5%RH 이하 및 75초의 응답 및 회복 속도를 보여주었다. 전극의 구조는 고분자 저항형 습도센서의 감습특성에 큰 영향을 미치며 전해질 고분자와 전극 사이의 활성화 에너지, 온도의존성, 감도, 직선성 및 히스테리시스와 같은 감습특성 등의 차이를 비교하였고 특히 이온의 이동에 관여하는 활성화 에너지 및 온도 의존성에 큰 영향을 미쳤다.

필름을 사용한 세기변조치료법에 대한 선량측정 (Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation)

  • 주상규;여인환;허승재;최병기;박영환;안용찬;김대용;공영건
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.172-178
    • /
    • 2002
  • 목적 : 원자 번호가 높은 물질로 구성된 필름은 저 에너지 광자선에 과반응하여 선량 측정 시 인체조직에서와 다른 흡수양상을 보인다. 이러한 현상은 조사면의 경계인 반음영 및 그 외곽 부위에서 두드러지게 관찰된다. 따라서 반음영이 조사면내에 위치하게되는 세기변조치료법에서 필름을 이용한 선량 측정 시 이러한 현상이 미치는 영향을 분석하고 개선 방법을 강구하고자 한다. 대상 및 방법 : 6 MV X-선의 5~7개의 크기가 다른 고정형 조사면을 이용해 두가지 유형의 세기변조 조사면을 만들었으며 전리함 및 저감도 측정용 필름을 사용하여 각 조사면의 빔 프로파일을 측정했다. 측정 깊이와 최대 조사면적을 변화시켰으며 필름에 대해 수직 및 수평 조사하여 이에 따른 선량 분포 변화를 관찰했다. 또한 필름 선량 측정시 저 에너지 광자선에 의한 선량 과평가 현상을 막기 위해 납 필터(0.01 inch)를 필름 양측에 부착하여 이로 인한 영향을 관찰했다. 결과 : 필름만을 사용한 빔 프로파일에서는, 전리함 측정치에 비해 저 선량 영역 및 조사면 경계에서의 선량 과평가 현상이 수직 및 수평 조사 모두에서 관찰되었다. 이러한 현상은 측정 깊이가 증가함에 따라 크게 나타났으며 10cm 깊이의 역 피라미드형 세기변조 조사면 중심에서 최고 약 15%의 상대오차를 보였다. 필터를 사용한 경우에서는, 수직 조사 시 필터에 의한 선량 저 평가 현상이 관찰되었으나 수평 조사에서는 전리함 측정치와 3% 이내의 오차를 보여 매우 잘 일치하였다. 결론 : 필름을 이용한 세기변조 조사면의 선량 측정 시 선량 과반응에 의한 오차는 조사면의 조합 형태 및 반음영 위치와 밀접한 관계를 가지며, 선량 평가 시 이에 대한 고려가 필요하다. 납 필터를 사용한 수평조사 방법은 이러한 오차를 줄이는데 도움을 주며 입사 방사선의 물리적 특성을 고려한 적정 두께의 필터 선택이 요구된다.