• 제목/요약/키워드: Silicone replica

검색결과 64건 처리시간 0.023초

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

고정성 보철물의 적합도에 대한 실험적 평가방법 (In vitro evaluation methods on adaptation of fixed dental prosthesis)

  • 이현호;이두형;이규복
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.63-70
    • /
    • 2017
  • 임상적으로 고정성보철물의 적합도는 성공적인 수복을 위해 필수적인 요소이다. 보철물의 적합도는 크게 변연적합도와 내면적합도로 분류되며, 이를 평가하기 위한 방법으로는 현미경 변연 측정법, 절단면 측정법, 실리콘 복제법, 3차원 스캔데이터 중첩법, 무게 측정법, 마이크로 CT 측정법 등 다양한 방법들이 소개되고 있다. 이에 본 연구에서는 기존의 문헌들을 바탕으로 각 방법들의 장, 단점을 비교분석함으로써 디지털환경에서 보다 편리하고 정확한 측정법을 제시하고자 한다.

치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석 (Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system)

  • 김원수;한만소;정재관;김기백
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

다른 스캐닝 방법으로 제작된 리튬 디실리케이트 단관의 변연 및 내면 적합도 평가 (Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods)

  • 김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제36권2호
    • /
    • pp.75-81
    • /
    • 2014
  • Purpose: This study was to compare adaptations of lithium disilicate CAD/CAM crowns fabricated with different scanning systems. Methods: This study selected the mandibular right first molar as an abutment for experiments and produced 10 working models. Lithium disilicate crowns appropriate for each abutment were produced by using a CEREC$^{(R)}$ CAD/CAM system. The independent t-test was then used to compare and analyze the data obtained from the two groups(${\alpha}$=0.05). Results: Mean(SD) adaptation were $86.93(22.82){\mu}m$ for the InS group, $88.42(26.77){\mu}m$ for the ExS group. They were no statistically significant differences between groups for adaptation(p>0.05). Conclusion: Within the limitations of this study, the results suggest that the accuracy of all investigated optical scanner were satisfactory for clinical use. Further assessment and improvement of the lithium disilicate ceramic for the fabrication of FPDs is evidently still required.

코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가 (Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy)

  • 김재홍;김원수;김기백
    • 한국치위생학회지
    • /
    • 제13권2호
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교 (Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.

도재 소성 과정에서의 고온이 지르코니아 코어의 변연적합도에 미치는 영향 (Influence of High Temperature of the Porcelain Firing Process on the Marginal Fit of Zirconia Core)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제13권2호
    • /
    • pp.135-141
    • /
    • 2013
  • 본 연구는 치과에서 사용되는 심미 보철물 중에 하나인 지르코니아 기반의 전부도재관 제작 시 지르코니아 코어 위에 상부 도재를 축성하고 소성하는 과정에서 발생되는 고온이 완성된 전부도재관의 변연적합도에 미치는 영향을 분석함으로써 임상적 허용이 가능한지 알아볼 뿐 아니라, 치과보철치료를 위한 치과의사, 치과위생사, 치과기공사의 보철물 선택 시 임상적 참고자료로 제공할 목적으로 수행되었다. 심미에 가장 많은 영향을 미치는 상악 중절치를 지대치로 선정하여 동일한 모형 10개 제작 후 각각의 지대치에 적합한 지르코니아 코어를 제작하였다. 제작된 코어의 변연적합도 측정 후 코어 위에 상부 도재를 축성하여 전부도재관을 완성한 뒤 2차 측정을 실시하였으며, 측정 후 비교 분석 된 결과는 다음과 같다. 변연적합도는 지르코니아 코어 제작한 후 전부도재관으로 제작되는 과정에 따라 더 커졌으며, 통계적으로도 유의한 차이를 보였다(p<0.001). 그러나 전부도재관에서 총 80회 측정된 변연적합도의 값에서 임상적 허용 수치인 $120{\mu}m$을 넘지 않는 결과를 보였으며, 이와 같은 결과를 토대로 지르코니아 코어 위에 상부 도재 소성 시 변연적합도가 커지긴하나 임상적으로 허용이 가능하다는 결론을 도출하였다.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

하고초 추출물의 항노화 효과에 관한 연구 (The Study on the Potential Anti-aging Properties of Prunella vulgaris Extract In Vitro and In Vivo)

  • 홍은숙;안기웅;조병기
    • 대한화장품학회지
    • /
    • 제34권2호
    • /
    • pp.129-135
    • /
    • 2008
  • 본 연구에서는 하고초(Prunella vulgaris) 추출물의 항노화 효과에 대하여 알아보고자 하였다. 시험 결과, 하고초 추출물의 콜라겐 생성 촉진 효과는 250 ${\mu}g/mL$ 농도에서 75.7%, MMP-1 생성 억제 효과는 200 ${\mu}g/mL$ 농도에서 90.2%로 나타났고, 엘라스테이즈 활성 억제 효과는 2.0% 농도에서 43.7%로 나타났다. 또한, 하고초 추출물의 항산화 효과 측정을 위한 자유 라티칼 소거 효과 시험 결과 2.0% 농도에서 76.9%의 소거 효과를 나타내었으며, 과산화수소에 의한 세포사멸 억제 효과는 2.0% 농도에서 49.9%로 나타났다. 하고초 추출물의 피부에 대한 영향을 알아보기 위하여 22명(연령분포 : 34세$\sim$48세)의 지원자를 대상으로 실시한 이중 맹검 임상 연구 결과, 하고초 추출물 4.0% 함유 제형을 12주간 도포하였을 때, 대조군과 비교하여 전문가의 육안평가, 모사판을 제작하여 주름의 정도를 분석한 결과 주름 개선에 현저한 효과가 있음을 확인하였다(p<0.05). 이러한 결과를 통해 하고초 추출물은 피부의 탄력과 주름을 효과적으로 개선함으로써, 천연 항노화 소재로 유용하게 이용될 수 있을 것으로 기대된다.

광간섭단층영상기를 이용한 치과용 지르코니아 코어의 적합도 분석 (Analysis of the Marginal and Internal Fit of Dental Zirconia Core Using Optical Coherence Tomography(OCT))

  • 김재홍;김기백
    • 한국콘텐츠학회논문지
    • /
    • 제12권8호
    • /
    • pp.240-247
    • /
    • 2012
  • 보철물이 구강 내 제 기능을 하기 위해 가장 중요한 요소 중 하나는 적합도이다. 본 연구의 목적은 그 동안 시도되지 않았던 광간섭단층영상기를 이용하여 비파괴적인 방법으로 적합도를 측정해보고, 측정된 값을 기존의 방법으로 측정된 값과 비교하여 보고자 한다. 실험을 위해 상악 우측 중절치가 지대치인 석고모형 10개를 제작하고 치과용 캐드캠으로 각각의 모형에 해당하는 지르코니아 코어를 10개 제작하였다. 시편 당 5부위 씩 광간섭단층영상기로 적합도를 측정하고, 같은 부위를 기존의 방법인 실리 복제본 기술로 측정하였다. 두 집단 간의 평균 값에 유의한 차이가 있는지 알아보기 위해 독립표본 t-검정을 실시하였다(${\alpha}$=0.05). 그 결과 측정된 두 집단 간의 평균 값에는 유의한 차이를 보이지 않았고(P>0.05), 이러한 결과로 미루어 볼 때 앞으로 광간섭단층영상기를 이용한 보철물의 적합도 측정이 가능할 것으로 사료된다.