• Title/Summary/Keyword: Silicone

Search Result 1,466, Processing Time 0.025 seconds

All-Solid-State Ion-Selective Electrodes With Organic Solvents Soluble Conducting Polymer for Chemical Sensor (화학센서를 위한 유기 용해성이 좋은 도전성 고분자가 포함된 전체 고체상태 이온 선택성 전극에 대한 연구)

  • Kim, Joong-Il;Park, Jong-Ho;Jang, Won;Heo, Min;Na, Young-Ho;Shin, Jae-Ho;Kim, Do-Young;Um, Hwan-Sub;Lee, Sang-Woo;Kim, In-Tae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.258-263
    • /
    • 2013
  • New conducting polymers containing heterocyclic ring with carbazole, EDOT and benzobisthiazole were synthesized and characterized by organic spectroscopic methods. Potentiometric ion-selective membrane electrodes (ISMEs) have been extensively used for ion analysis in clinical, environmental, and industeial fields owing to its wide response range (4 to 7 orders of magnitude), no effect of sample turbidity, fast response time, and ease of miniaturization. Considerable attention has been given to alternative use of room temperature vulcanizing (RTV)-type silicone rubber(SR) owing to its strong adhesion and high thermal durability. Unfortunately, the high membrane resistance of SR-based (ISMs)(2 to 3 higher orders of magnitude compared to those of poly(vinyl chloride)(PVC)-based ones) has significantly restricted its application. Herein we demonstrate a new method to reduce membrane resistance via addition of new conducting polymer into the SR-based ISMs.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Effects of Fume silica on synthesis of New Austria Tunnel Method Resin for new material in space aviation (우주항공의 신소재를 위한 New Austria Tunnel Method 수지합성에 대한 Fume silica의 영향)

  • Kim, Kijun;Lee, Jooho;Park, Taesul;Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.595-601
    • /
    • 2014
  • The microstructures of NATM were examined by SEM, FT-IR spectra, tensile properties, mole % of [NCO/OH], and particle size analyzer. Growing concerns in the environment-friendly industries have led to the development of solvent-free formulations that can be cured. We had synthesized NATM(New Austria Tunnel Method) resin having the ability to protect stainless steel against corrosion. Comparing with general NATM resin and coatings, this resin that synthesized with polyurethane and epoxy was highly stronger in intensity and longer durability. Hybrid resin was composed of polyols, MDI, epoxy, silicone surfactant, catalyst and crosslink agent, and fillers. Moreover, fillers such as fume silica not only accelerated the curing rate but also improved the physical property as thermal barriers. The rigid segments of synthetic resin in mechanical properties were due to fume silica and the increase the mole% of [NCO/OH] for corrosion protection. In conclusion, the hybrid resin microstructure with crosslink agent and fume silica are good material for thermosetting coating of metal substrates such as stainless steel.

THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS (금합금 연마재 종류에 따른 금합금 소실량과 연마 정도)

  • Kim, Myoung-Hwa;Yim, Soon-Ho;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.277-295
    • /
    • 1997
  • After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF-30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green clasp polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as $0.329{\mu}m$ and Shofu supergreen point had the lowest value as $0.022{\mu}m$. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, In Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.

  • PDF

Rhinoplasty using Various Autogenous Tissues (다양한 자가조직을 활용한 비성형술)

  • Han, Ki-Hwan;Yeo, Hyeon-Jung;Choi, Tae-Hyun;Kim, Jun-Hyung;Son, Dae-Gu
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Purpose: In Korean rhinoplasty, alloplasts such as silicone rubber have been used for dorsal and tip augmentations. However, alloplasts have produced complications such as deviation, exposure, and infection. Although autogenous tissue is an ideal material, the amount of the cartilage in Korean is not sufficient. Therefore, the authors developed a method to harvest the maximum amount of the septal and conchal cartilage. The authors first performed a complete septal extension graft for short and retruded columella and then performed nasal augmentation using various autogenous tissues. Methods: These surgical techniques were performed on 11 patients. Their average age was 27 years. An open approach with a V-shaped columellar labial incision was performed. At first, the complete septal extension graft was fixed on the entire caudal margin of the septum, and the alar cartilage was suspended to the septal extension graft to make the tip projected and the columella advanced caudally. A temporal fascial ball was used for radix augmentation. For dorsal augmentation, a batten-shaped septal cartilage graft wrapped with or without the temporal fascia or a diced cartilage graft wrapped with the temporal fascia was performed. For nasal tip augmentation, a shield graft and a cap graft or a folded conchal cartilage graft was performed.Results: The mean follow-up period was 11.2 months. The overall results were natural and satisfactory. Two patients underwent slight absorption and caudal displacement. With the exception of these cases, no complications were observed. Conclusion: Korean rhinoplastic surgeons are accustomed to using the alloplasts despite of serious complications. When rhinoplasty using autogenous tissue was performed, some complications occurred such as the displacement of the diced cartilage graft wrapped with the fascia, but many of the complications of alloplastic rhinoplasty were avoided. Therefore, we propose that by this time Korean rhinoplastic surgeons need to change their preference from alloplastic rhinoplasty to autogenous rhinoplasty.

The necessary & method of scrotoplasty in female to male transgender (여성에서 남성으로의 성전환증에서 음낭성형술의 필요성과 방법)

  • Kim, Seok-Kwun;Moon, In-Sun;Kwon, Yong-Seok;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.437-444
    • /
    • 2009
  • Purpose: Transgender is a disorder of gender identity, who have appropriate chromosomal, hormonal and anatomical characteristics corresponding to their sexual phenotype but feel strongly with respect to their sexual identity, that they belong to the opposite sex. There is a persistence discomfort and sense of inappropriateness about one's assigned sex in a person who has reached puberty. Transgender is a psychiatric problem, but surgical method provides more satisfactory adjustment for patients. In gender reassignment surgery for female to male transgender, mastectomy, nipple reduction, hysterectomy, oophorectomy and phalloplasty are included. And as the final operation, recommended for scrotoplasty and artificial testes insertion. So we investigated the necessity and method of scrotoplasty in the final operation of female to male transgender. Method: The authors have long term follow-up of 75 cases female to male transgender during January, 1991 to February, 2008. Among them, 13 cases were evaluated in this study. During phalloplasty, the labium major skin preserved. And this labium majoral skin flap was made for the neoscrotum. At least six months later, artificial testes were inserted in neoscrotum with local anesthesia. Middle sized (3 cm diameter) artificial testes(silicon gel or carving soft silicone implant) were used because of the limitation of the neoscrotum. We evaluated the questionnaire and interview about the postoperative satisfaction in configuration of reconstructed scrotum, and the necessity of operation, the postoperative psychosocioeconomic improvement and limitation of body exposure activities such as swimming, public bathing. Results: Based on this study, satisfaction of reconstructed scrotum after scrotoplasty was improved(92%). The necessity of scrotoplasty was in 92.3% and the postoperative psychosocioeconomic well - being improvement was 77% in answers. Less limitation of activities requiring body exposure was 54% in answers. Most of the patients were satisfied with the results of surgical operation inspite of the operative procedure had some postoperative complications. Conclusion: This study was reported that the scrotoplasty in female to male transgender is not only a conversion of external genitalia but also an improvement of psychosocial state. Most patients sincerely hope to this operation, so we improve our surgical method for more good results.

A Study on the Non-Toxic Compound-based Multi-layered Radiation Shielding Sheet and Improvement of Properties (무독성 화합물 기반의 다층 구조 방사선 차폐 시트 개발과 특성 개선에 관한 연구)

  • Heo, Ye Ji;Yang, Seung u;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.149-155
    • /
    • 2020
  • Most of radiation protection clothing is made of lead with excellent radiation shielding because it has excellent process ability and economic efficiency and has a high atomic number. However, lead is classified as a hazardous heavy metal, and there is a risk of lead poisoning. Recently, research to replace lead has been actively conducted. In this study, a research on a shielding sheet with improved physical properties while maintaining the radiation shielding ability equivalent to that of conventional materials by mixing two materials that are harmless to the human body, such as BaSO4 and Bi2O3, and a silicone material binder Was performed. For comparison evaluation with the existing lead shielding sheet, the shielding rate was evaluated using a 40 degree shielding sheet having the highest porosity. As a result, it was analyzed that the shielding rate was superior to 9 % or more at the same thickness. In addition, as a result of studies to improve the physical properties of the shielding sheet, it was analyzed that the shielding sheet mixed with BaSO4/nylon/Bi2O3 was the best.

Nasal Anthropometry on Facial Computed Tomography Scans for Rhinoplasty in Koreans

  • Moon, Kyung Min;Cho, Geon;Sung, Ha Min;Jung, Min Su;Tak, Kyoung Seok;Jung, Sung-Won;Lee, Hoon-Bum;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.610-615
    • /
    • 2013
  • Background Cephalometric analysis is essential for planning treatment in maxillofacial and aesthetic facial surgery. Although photometric analysis of the Korean nose has been attempted in the past, anthropometry of the deeper nasal structures in the same population based on computerized tomography (CT) has not been published. We therefore measured three anthropometric parameters of the nose on CT scans in our clinical series of patients. Methods We conducted the current retrospective study of a total of 100 patients (n=100) who underwent a CT-guided radiological measurement at our institution during a period ranging from January of 2008 to August of 2010. In these patients, we took three anthropometric measurements: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone. Results The mean nasofrontal angle was $131.14^{\circ}$ in the male patients and $140.70^{\circ}$ in the female patients. The mean linear distance between the nasion and the tip of the nasal bone was 21.28 mm and 18.02 mm, respectively. The mean nasal pyramidal angle was $112.89^{\circ}$ and $103.25^{\circ}$ at the level of the nasal root, $117.49^{\circ}$ and $115.60^{\circ}$ at the middle level of the nasal bone, and $127.99^{\circ}$ and $125.04^{\circ}$ at the level of the tip of the nasal bone, respectively. Conclusions In conclusion, our data will be helpful in the preparation of silicone implants for augmentation and/or corrective rhinoplasty in ethnic Korean people.

Surface Apatite Growth of NaOH and SBF Treated CP-Ti, Ti-6Al-4V and ECAP-Ti (NaOH처리와 SBF침적에 따른 CP-Ti, Ti-6Al-4V 및 ECAP-Ti의 표면 아파타이트 성장)

  • Oh Seok-Jin;Ruy Jae-Gyeoung;Lee Seung-Woo;Kim Yun-Jong;Han Man-So;Kim Chang-Hyu
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.893-899
    • /
    • 2004
  • Even though Ti-6Al-4V has gained popularity as an implant material, the possible dissolution of Al and V ions in body fluids remains a matter of concern. Though commercially pure Ti (Cp-Ti) overcomes this problem, the mechanical strength of pure titanium remains very low. Thus, in this experiment Cp-Ti was processed by Equal channel angular processing (ECAP), in order to increase the mechanical strength. The biocompatibility of ECAP-Ti, Cp-Ti and Ti-6Al-4V was examined by the apatite formation on each sample surface, after treating the surface with 5M NaOH and soaking in Simulated body fluids (SBF). Initially, the samples were mechanically polished on silicone carbide paper (#2000). The polished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. The NaOH treated samples were washed gently with distill water and dried at $40^{\circ}C$ for 1 day. The dried samples were heat treated in air at $600^{\circ}C$ for 1 hour. The surface morphology of these samples were studied using SEM and XRD. The SEM studies showed network of pores in all samples. The XRD showed oxide layer formation on Cp-Ti and Ti-6Al-4V. samples. However the oxide layer in ECAP-Ti was not substantial. These samples were immersed in SBF, kept at $36.5^{\circ}C$ for seven days period. At the end of 7 days, the apatite formation was confirmed only on Cp-Ti and was not observed in Ti-6Al-4V and ECAP-Ti. These observations of apatite formation relate to the fact that Cp-Ti showed greater oxide layer than other samples. The apatite examined was confirmed as tricalcium phosphate (TCP) using EDS and XRD.