• Title/Summary/Keyword: Silicone

Search Result 1,466, Processing Time 0.025 seconds

A QUALITATIVE AND QUANTITATIVE STUDY ON OCCLUSAL CONDITIONS IN HEALTH VOLUNTEERS AND ATHLETES WITH NORMAL OCCLUSION (정상인과 체육인의 교합상태에 대한 정상적.정량적 비교 연구)

  • Jang, Jung-Mi;Lee, Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.302-322
    • /
    • 1998
  • This study was accompolished to analyze and compare the number and area of the occlusal contact points in healthy volunteers and athletes with normal occlusion. For this study, 15 athletes(13 amles and 2 females with average age 20) and 21 healthy volunteers(14 mles and 7 females with average age 20.09) were selected. The visual display acquired by scanning of occlusal record in maximal intercuspation was converted into 16 gray value image. Then, using computer program(J & Lee Occlusal Analyser), the pixel which was in definite range of the gray value was recognized, and the numbers of recognized pixel were calculated to area. The results were as follows ; 1. The average numbers of total occlusal contact feints were 31.05 in control group, and 34.67 in athlete group. The average area of total occlusal contacts was $100.25mm^2$ in control group, and $127.78mm^2$ in athlete group. 2. In control group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.48), the second molar(8.24), the second premolar(4.71), the lateral incisor(2.90), the first premor(2.43), the central incisor(2.19), and the canine(2.1). The least average in canine(2.1) was similar to the average(2.19) in central incisor and (2.09) in lateral incisor. In athlete group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.97), the second molar(8.47), the second premolar(5.60), the canine(3.80), the lateral incisor(3.33), the first premolar(2.67), and the central incisor(1.93). 3. In control group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($39.47mm^3$), the second molar($37.54mm^3$), the second premolar($9.54mm^3$) the first premolar($6.18mm^3$), canine($3.49mm^3$), the central incisor($2.76mm^3$), and the lateral incisor($1.28mm^3$). In athlete group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($44.11mm^3$), the second molar($40.69mm^3$), the second premolar($16.50mm^3$), the first premolar($9.39mm^3$), the canine($5.08mm^3$), the lateral incisor($3.7mm^3$), and the central incisor($2.25mm^3$). 4. With aging in both control and athlete group, there was a decreasing tendancy in average number of occlusal contact point, and was an increasing tendancy in average area of occlusal contact surface. In comparison at each age, both the numbers and area of occlusal contact were greater in athlete group than in control group. It was not significant in the numbers of occlusal contact points beween athlete and control group(p>0.1), but significant in the area of occlusal contact surface(p<0.03). 5. In comparision as to the kind of sports(Gymnastics : 2, Rugby : 3, Soccor : 5, Ice hocky : 5), the numbers of occlusal contact points were the most in ice hocky, and the area of occlusal contact surface was the greatest in gymnastics. With increasing a career in athlete group, there was a decreasing tendancy in average numbers of occlusal contact points and was an increasing tendancy in average area of occlusal contact surface. 6. By T-scan analyzing, the contact numbers on the anterior teeth were greater in control group than in athlete group, and on the posterior teeth were greater in athlete group than in control group. And the results acquired by T-scan were lesser than that caquired by the silicone bite records. It was not significant in the posterior teeth, but significant in the anterior teeth. In T-scan records, the numbers of occlusal contact points on second molar were the greatest, but in the silicone records, the numbers on first molar were the greatest.

  • PDF

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Scientific Study on Clepsydra of Changgyeonggung Palace, National Treasure for Diagnosis on State of Conservation (국보 창경궁 자격루 누기의 보존상태 진단을 위한 과학적 조사)

  • YOU Harim;LEE Jaesung;YU Jia;JO Hanui;PARK Younghwan;RYU Dongwan
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.3
    • /
    • pp.138-156
    • /
    • 2023
  • Some of the metal cultural heritage that make up a considerable proportion of Korea's cultural heritage have been installed and displayed outdoors due to their own functions, roles, and scale. Therefore, more diverse and complex damages can occur outdoors than they are in a stable environment. Therefore, it is necessary to combine accurate diagnosis and systematic survey methods in order to utilize basic data obtained from research results as data for the long-term and continuous conservation management as well as to do the research to diagnose the conservation status of outdoor cultural heritage. The clepsydra(hereinafter referred to as Jagyeongnu) of Changgyeonggung Palace, the National Treasure has been installed and displayed outdoors since it was manufactured. Though regular conservation and maintenance of the Jagyeongnu have been carried out, damage still occurred. Therefore, the scientific research on Jagyeongnu to diagnose the state of conservation was conducted prior to the full-scale conservation treatment. First, the state of conservation was investigated with an examination of basic data, macroscopic inspections and past records of repair history according to the purpose of the research. More detailed examinations were also conducted through the 3D scan, surface pattern investigation, and color difference analysis, and the analysis on materials and contaminants were conducted through P-XRF, FT-IR, and Py-GC/MS. The scientific research reveals that squalane and silicone oil have been applied in the past for conservation treatment and directly exposed to outdoor environmental factors, which caused damage to Jagyeongnu and contaminants such as dust adhered thickly to its surface, accelerating severe damage. A greater incidence of damage was found around the part with relatively high exposure effect, which corresponded with the tendency identified by grouping color difference data. As a result of integrating various research methodologies to diagnose the state of conservation and secure basic data, the causes and types of damage were identified. Furthermore, the process of obtaining digital data to be utilized in various ways, and the color difference analysis presenting visible damage as scientific data and identifying the tendency of damage patterns were confirmed to have been effective.

CLINICAL STUDY OF AUGMENTATION MALARPLASTY WITH POROUS POLYETHYLENE (Porous polyethylene을 이용한 관골증대술의 임상연구)

  • Kook, Min-Suk;An, Jin-Suk;Kim, Young-Joon;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.283-291
    • /
    • 2008
  • The malar mound defines the contour of the lateral face between the inferior orbital rim and the mandible, and hypoplasia or asymmetry of this region is readily noticeable. A flat, hypoplastic malar eminence can make the face blunt and wearisome, which contributes to a premature aged appearance. Patients with congenital or traumatic flattening of the malar eminence can obtain esthetic improvement with implants. Indications for placement of malar implants to improve the appearance of subtle flattening or to enhance the esthetic harmony of a patient's face have been suggested in several studies. Many augmentation materials, such as silicone, proplast, polyamide, and porous polyethylene implants have been used. Many methods of localization have been described, the key to proper placement of the implants lies in a through understanding of the esthetics of the malar mound. From August 2001 to June 2007, 12 patients with malar depression who visited the Department of Oral and Maxillofacial Surgery, Chonnam National University Hospital were treated by augmentation malarplasty with Porous polyethylene. The location and amount of augmentation are determined by preoperative interview, physical examinations, facial models and radiographic findings. 12 patients were satisfied with the results of augmentation malarplasty and severe complications were not occurred.

Changes in occlusal force depending on the movement of the adjacent and opposing teeth after loss of lower first molar: comparative study by using a strain gauge (하악 제1대구치 상실 시 인접 및 대합 치아들의 이동양상에 따른 교합력 변화: 스트레인게이지를 이용한 비교 연구)

  • Song, Myoung-Ja;Park, Ji-Man;Chun, Youn-Sic
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.47-59
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the changes in occlusal force after loss of the lower first molar depending on the inclination and extrusion of the adjacent and opposing teeth by using a strain gauge. Materials and Methods: Anatomic teeth were used to reconstruct the normal dental arch with loss of the lower right first molar. A uniformly thick layer of silicone was applied to the root to mimic the periodontal ligament. Four stages of dies with varying degrees of inclination and extrusion of the adjacent and opposing teeth were constructed and attached to master model interchangeably by using a CAD/CAM fabricated customized die system. The strain gauges were attached to teeth and a universal testing machine was used to determine the changes in occlusal force. An independent t-test and one-way ANOVA were performed (${\alpha}=.05$). Results: While simulating chewing food, the upper first, second premolar and lower second molar showed greater occlusal force than before extraction. When the change of adjacent teeth's occlusal force with their progressive movement after molar loss was evaluated, the difference among four die models was significant and was in the decreasing aspect (P < 0.05). Conclusion: When the lower first molar was lost and the adjacent teeth did not move yet, the occlusal force in adjacent teeth was higher than that when the lower first molar still existed. In addition, the occlusal force in the upper premolars and lower second molar decreased significantly with the progressive movement of adjacent teeth.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.

Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구)

  • Kim, Dae-Hoon;Kim, Guang-Lim;Jo, Hang-Dae;Park, Jong-Soo;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.660-667
    • /
    • 2010
  • In this research polyimide, Matrimid 5218, hollow fiber membrane was used to recover sulfur hexafluoride($SF_6$) which is one of the six greenhouse gases from $N_2/SF_6$ mixture gas. Fibers were spun from using dry-wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a sponge-like substructure. The developed module had a permeance of 0.78-1.36 GPU for $N_2$ with $N_2/SF_6$ selectivity of 2.44-5.08 at various pressure and temperature. For recovery of $SF_6$, a membrane module and 10 vol.% $SF_6$ from $N_2/SF_6$ mixture gas was used. The effects of various operating condition such as pressure, temperature, and retentate side flow rate were tested. When pressure and temperature were increased and retentate flow rate was decreased, the $SF_6$ purity in recovered gas was increased up to 37.5 vol.% with decreasing recovery ratio. When retentate flow rate was increased pressure and temperature was decreased, the $SF_6$ recovery ratio in retentate side was increased up to 89% with decreasing the $SF_6$ purity in retentate side.

Performance Characteristics of p-i-n type Organic Thin-film Photovoltaic Cell with Rubrene:CuPc Hole Transport Layer (Rubrene:CuPc 정공 수송층이 도입된 p-i-n형 유기 박막 태양전지의 성능 특성 연구)

  • Kang, Hak-su;Hwang, Jongwon;Kang, Yongsu;Lee, Hyehyun;Choe, Youngson
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.654-659
    • /
    • 2010
  • We have investigated the effect of rubrene-doped CuPc hole transport layer on the performance of p-i-n type bulk hetero-junction photovoltaic device with a structure of ITO/PEDOT:PSS/CuPc: rubrene/CuPc:C60(blending ratio 1:1)/C60/BCP/Al and have evaluated the current density-voltage(J-V) characteristics, short-circuit current($J_{sc}$), open-circuit voltage($V_{oc}$), fill factor(FF), and energy conversion efficiency(${\eta}_e$) of the device. By rubrene doping into CuPc hole transport layer, absorption intensity in absorption spectra decreased. However, the performance of p-i-n organic type bulk hetero-junction photovoltaic device fabricated with crystalline rubrene-doped CuPc was improved since rubrene shows higher bandgap and hole mobility compared to CuPc. Increased injection currents have effected on the performance improvement of the present device with energy conversion efficiency(${\eta}_e$) of 1.41%, which is still lower value compared to silicone solar cell and many efforts should be made to improve organic photovoltaic devices.