• Title/Summary/Keyword: Significant Motion Sensor

Search Result 44, Processing Time 0.026 seconds

Sports Biomechanical Analysis before and after Applying Weight Belt during Squat Exercise (스쿼트 동작 시 웨이트 벨트 착용 전·후에 따른 운동역학적 분석)

  • LEE, Jeong-Ki;HEO, Bo-Seob;KIM, Yong-Jae;LEE, Hyo-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.893-902
    • /
    • 2016
  • The purpose of this study is to investigate the effect of wearing a weightlifting belt, which is an auxiliary equipment used during squat, by measuring and analyzing biomechanical difference in lower limb and proposing safer and to suggest a more effective exercise method for general population. Selected 8 male participants in their 20s who have not performed regular resistance exercise for at least a year, but have experience of performing squat. The comprehensive method of study is as follows: subjects were notified of the purpose of the study and were told to practice warm-up and the squat motion for the experiment for 20 minutes. When the participant believed they were ready to begin, the experiment was started. At controlled points, foot pressure distribution sensor has been installed. Then left and right feet have been placed on the pressure distribution sensor, from which data for successful squat position that does not satisfy the criteria for failure have been collected and computed with Kwon3D XP program and TPScan program. For data processing of this study, SPSS 21.0 was used to calculated mean (M) and standard deviation (SD) of the analyzed values, and paired t-test has been conducted to investigate the difference before and after wearing the weightlifting belt, with p-value of ${\alpha}<.05$. As for time consumed depending on usage of weightlifting belt in squat, statistically significant difference has been found in P2, which is recovery movement. Lower limb angle depending on usage of weightlifting belt in squat has shown statistically significant difference in E1 foot joint(p<. 001). There has been statistically significant difference in E2 knee joint. Foot pressure percentage depending on usage of weightlifting belt in squat were found to be statistically significant (p<. 01) in both regions of anterior and posterior foot.

Comparative analysis of Peak Impulsive Force and Maximum Velocity according to the Taekwondo Jeongkwon Jirigi's Pattern (태권도 정권지르기 방식에 따른 최대 충격력과 최고속도 비교)

  • Ahn, Jeong-Deok
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.389-395
    • /
    • 2012
  • This research analyzed the peak impulsive force, maximum velocity and a spot of fist's maximum velocity comparing stop-jirugi and push-jirugi. 7 males volunteered for this experiment. peak impulsive force was measured by PS2142 force platform[10], and maximum velocity of fist was measured by PS2103A motion sensor[12]. All of data was collected in the data studio and t-test was applied using SAS 9.1 package. The following conclusions were drawn. First, stop-jirugi's peak impulsive force was greater (P<.01) than that of push-jirugi. Second, push-jirugi's maximum velocity of fist was greater (P<.01) than that of stop-jirugi. Third, stop-jirugi's maximum velocity of fist was occurred on 69.14% of arm's length and that of push-jirugi was occurred on 75.66%. This maximum velocity spot was statistically significant difference(p<.001).

An Experimental Analysis of the Flow Field in an Air Induction System by Flow Visualization and LDV Measurements (유동 가시화와 LDV 측정을 이용한 흡기계 내의 유동장에 관한 실험적 해석)

  • 유성출
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.102-111
    • /
    • 2001
  • To describe the air flow characteristics within an air cleaner cover and mass air flow sensor (MAFS) entry region installed in a 3.0L engine air induction system, flow visualization, velocity and turbulence intensity measurements were taken in several view planes. A detailed knowledge of the interaction between the design parameters and the flow structures will enhance our understanding of the motions within the flow field and enable engineers to optimize the induction system and reduce the signal-to-noise ratio in the MAFS output. Emphasis is placed on the analysis of coherent motions and the controlling parameters which affect the air flow in the MAFS entrance region over a flow rate of 13-240 kg/hr. The high speed motion pictures illustrated that the air flow generated within the air cleaner cover under steady state condition is quite complex. In both axial and radial planes of the main passage it was found that the flow pattern is remarkably influenced by the air cleaner cover and main passage configuration. A comparison of the flow patterns and measurements in the original and modified air cleaner cover is presented. Measurements from the MAFS indicated an significant reduction in pressure drop and signal noise for the modified cover as compared with the original cover, over an air flow rate of 13-240 kg/hr.

  • PDF

A Study on the Evaluation of the Appropriateness of the Control of Departure of Tugs Based on the Analysis of Ship Dynamic Motion (선체운동 해석 기반의 예인선 출항통제 적정성 평가에 대한 연구)

  • Tae-Hoon Kim;Yong-Ung Yu;Yun-sok Lee;Young-Joong Ahn
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.307-315
    • /
    • 2023
  • Korea controls the departure of vessels based on the Maritime Safety Act such that only ships with seaworthiness can navigate in bad weather, but scientific evaluation results and quantitative basis for the designation of ships subject to control are insufficient. Opinions for improvement are being raised for a reasonable departure control operation. The purpose of this study is to evaluate the adequacy of the current departure control standards through actual measurement of tugboats, which are the type of vessels subject to control when a wind and wave advisory is effective, and to present quantitative grounds for improvement of controls. A sensor was installed on the tugboat to measure the ship's three-axis motion and hull acceleration, and the hull motion performance was measured by operating in the sea area with a significant wave height of 3 m. The measured values were compared and analyzed based on seaworthiness evaluation factors and limit value standards. The actual ship was excluded from the current control standard according to tonnage, but as a result of the analysis, the pitch value exceeded the operation standard, and a risk to navigation safety existed. The results of this study suggest the need for additional actual measurement studies that can represent various ship types and specifications and review ship departure control targets.

A Study on the Piezoelectric Energy Harvesting Using SSHI Technique (SSHI 기법을 이용한 압전소자로부터의 에너지 회수에 대한 연구)

  • Nam, Yoon-Su;Park, Jong-Soo;Park, Hae-Gyoon;Lee, Jae-Kang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.92-98
    • /
    • 2008
  • The target of this paper is to study on the usefulness of the SSHI technique as a wireless electrical power supply when it is driven by mechanical vibrations of low frequency. A THUNDER series a piezoelectric material (TH7-R), which has been developed by a NASA engineer is selected for this study. A mechanical motion vibrator supplies piezoelectric material with mechanical energy. An optical fiber sensor and a pulse generating circuit are used to accomplish the parallel-SSHI technique. As a result of this study, energy harvesting using SSHI technique results in a significant increase of the electrical power flow.

Arm Lifting Exercises for Lower Trapezius Muscle Activation

  • Kang, Minhyeok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1868-1872
    • /
    • 2019
  • Background: Lower trapezius muscle function is important for the prevention and treatment of shoulder injuries. However, scapular posterior tilt movement has been overlooked in lower trapezius strengthening exercise programs. Objective: To examine the effects of prone arm lifting with scapular posterior tilt (PALSPT) on trapezius muscles. Design: Crossover study Methods: 17 healthy males were recruited for participation in this study. Participants performed backward rocking diagonal arm lifting (BRDAL) and PALSPT. To train participants in scapular posterior tilt movements for PALSPT, visual biofeedback of scapular movements was provided using a motion sensor. Electromyography (EMG) activities of the middle and lower trapezius were recorded using a surface EMG system. Differences in middle and lower trapezius muscle activity between BRDAL and PALSPT exercises were analyzed. Results: Lower trapezius muscle activity was significantly greater during PALSPT than during BRDAL (p=.006). Although greater EMG activity was observed in the middle trapezius during PALSPT than during BRDAL, this difference was not significant (p=.055). Conclusions: The results of the present study indicate that scapular posterior tilt movements must be considered in lower trapezius muscle strengthening programs.

The change of ankle of plantar pressure and range of motion joint according to treadmill gradients (트레드밀보행 시 경사도에 따른 족저압과 발목관절의 관절가동범위의 변화)

  • Kim, Tae-Ho;Kim, Byoung-Gon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.39-47
    • /
    • 2008
  • Purpose : The purpose of this study was to investigate the change of the peak plantar pressure distribution under the foot areas and the range of motion (ROM) of ankle joint according to gradients in treadmill gait. Method : Thirty normal subjects (15 male and 15 female) walked on treadmill at three gradient conditions ($0^{\circ}$, $10^{\circ}$, and $15^{\circ}$) in normal speed. The ankle ROM was measured using the CMS70P that is three dimensional analyzer for excursion of ankle ROM, plantar flexion, and dorsi flexion. The peak plantar pressure distribution under the hallux, 1st metatarsal head (MTH) and heel was measured using the F -Scan system with an in-shoe sensor. Data was collected from 9 steps of left sife foot in at each gradient condition while all subjects walked. Result : As the treadmill gradient increased, the excursion of ankle joint was significantly increased (p<.05). Also, plantar flexion and dorsi flexion was significantly increased according to treadmill gradients (p<.05). The peak plantar pressure under the 1st MTH was significantly increased (p<.05) and the peak plantar pressure under the heel was significantly decreased (p<.05) as the treadmill gradient increased. No significant different in the peak plantar pressure under the hallux was observed. Conclusion : This study suggests that physical therapy for patients who have limited ankle ROM should be considered sufficient range of motion for functional ambulation. And individuals that have painful forefoot syndromes, including metatarsalgia, hallux valgus, and plantar ulceration should be careful in walking to uphill, as there is high plantar pressure under the forefoot.

  • PDF

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Accuracy Comparison of Spatiotemporal Gait Variables Measured by the Microsoft Kinect 2 Sensor Directed Toward and Oblique to the Movement Direction (정면과 측면에 위치시킨 마이크로 소프트 키넥트 2로 측정한 보행 시공간 변인 정확성 비교)

  • Hwang, Jisun;Kim, Eun-jin;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: The Microsoft Kinect which is a low-cost gaming device has been studied as a promise clinical gait analysis tool having satisfactory reliability and validity. However, its accuracy is only guaranteed when it is properly positioned in front of a subject. Objects: The purpose of this study was to identify the error when the Kinect was positioned at a $45^{\circ}$ angle to the longitudinal walking plane compare with those when the Kinect was positioned in front of a subject. Methods: Sixteen healthy adults performed two testing sessions consisting of walking toward and $45^{\circ}$ obliquely the Kinect. Spatiotemporal outcome measures related to stride length, stride time, step length, step time and walking speed were examined. To assess the error between Kinect and 3D motion analysis systems, mean absolute errors (MAE) were determined and compared. Results: MAE of stride length, stride time, step time and walking speed when the Kinect set in front of subjects were investigated as .36, .04, .20 and .32 respectively. MAE of those when the Kinect placed obliquely were investigated as .67, .09, .37, and .58 respectively. There were significant differences in spatiotemporal outcomes between the two conditions. Conclusion: Based on our study experience, positioning the Kinect directly in front of the person walking towards it provides the optimal spatiotemporal data. Therefore, we concluded that the Kinect should be placed carefully and adequately in clinical settings.