• Title/Summary/Keyword: Signal-to-noise Ratio

Search Result 3,035, Processing Time 0.031 seconds

Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging (고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현)

  • Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.238-246
    • /
    • 2017
  • High frequency ultrasound imaging typically suffers from low sensitivity due to the small aperture of high frequency transducers and shallow imaging depth due to the frequency-dependent attenuation of ultrasound. These limitations should be overcome to obtain high-frequency, high- resolution ultrasound images. One practical solution to the problems is a high-performance signal receiver capable of detecting a very small signal and amplifying the signal with minimal electronic noise addition. This paper reports a recently developed low-noise, wideband ultrasound receiver for high-frequency, high-resolution ultrasound imaging. The developed receiver has an amplification gain of up to 73 dB and a variable amplification gain range of 48 dB over an operating frequency of 80 MHz. Also, it has an amplification gain flatness of ${\pm}1dB$. Due to these high performances, the developed receiver has a signal-to-noise ratio of at least 8.4 dB and a contrast-to-noise ratio of at least 3.7 dB higher than commercial receivers.

Nose Estimation and Suppression methods based on Normalized Variance in Time-Frequency for Speech Enhancement (음성강화를 위한 시간 및 주파수 도메인의 분산정규화 기반 잡음예측 및 저감방법)

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.1
    • /
    • pp.87-94
    • /
    • 2009
  • Noise estimation and suppression are a crucial factor of many speech communication and recognition systems. In this paper, proposed algorithm is based on the ratio of variance normalized of noisy power spectrum in time-frequency domain. Our proposed algorithm tracks the threshold and controls the trade-off between residual noise and distortion. This algorithm is evaluated by the ITU-T P.835 signal distortion (SIG) and segment signal to noise ratio (SNR), and is superior to the conventional methods.

Co-Simulation for Systematic and Statistical Correction of Multi-Digital-to-Analog-Convertor Systems

  • Park, Youngcheol;Yoon, Hoijin
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • In this paper, a systematic and statistical calibration technique was implemented to calibrate a high-speed signal converting system containing multiple digital-to-analog converters (DACs). The systematic error (especially the imbalance between DACs) in the current combining network of the multi-DAC system was modeled and corrected by calculating the path coefficients for individual DACs with wideband reference signals. Furthermore, by applying a Kalman filter to suppress noise from quantization and clock jitter, accurate coefficients with minimum noise were identified. For correcting an arbitrary waveform generator with two DACs, a co-simulation platform was implemented to estimate the system degradation and its corrected performance. Simulation results showed that after correction with 4.8 Gbps QAM signal, the signal-to-noise-ratio improved by approximately 4.5 dB and the error-vector-magnitude improved from 4.1% to 1.12% over 0.96 GHz bandwidth.

A Study on Impulse Noise Removal on using Directional Mask (방향성 마스크를 이용한 임펄스 잡음 제거에 관한 연구)

  • Hong, Sang-Woo;An, Young-Joo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.795-797
    • /
    • 2014
  • Image treatment has grown in its necessity in many fields due to the development of display technology used in smart phones and tablet computers. In digital imaging technology, noise is created by many causes during the process of acquiring, transmitting and treating image data. Therefore, this paper suggests a median filter that is more competent in removing noise by taking into account the direction when restoring noisy images that have been damaged by impulse noise. In order to verify the noise removal characteristics, PSNR(peak signal to noise ratio) was used for comparison against existing methods.

  • PDF

SDR Based Modulation Performance of RF Signal under Different Communication Channel

  • Shabana Habib
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.3
    • /
    • pp.182-188
    • /
    • 2024
  • Hardware components are an integral part of Hardware Define Radio (HDR) for seamless operations and optimal performance. On the other hand, Software Define Radio (SDR) is a program that does not rely on any hardware components for its performance. Both of the latter radio programmers utilize modulation functions to make their core components from signal processing viewpoint. The following paper concentrates on SDR based modulation and their performance under different modulations. The bit error rate (BER) of modulations such as PSK, QAM, and PSAM were used as indicators to test channel quality estimation in planar Rayleigh fading. Though it is not commonly used for channel fading, the method of the adder determines the regionally segmented channel fading. Thus, the estimation error of the channel change substantially reduces the performance of the signal, hence, proving to be an effective option. Moreover, this paper also elaborates that BER is calculated as a function of the sample size (signal length) with an average of 20 decibels. Consequently, the size of the results for different modulation schemes has been explored. The analytical results through derivations have been verified through computer simulation. The results focused on parameters of amplitude estimation error for 1dB reduction in the average signal-to-noise ratio, while the combined amplitude deviation estimation error results are obtained for a 3.5 dB reduction

Speech Enhancement Using the Adaptive Noise Canceling Technique with a Recursive Time Delay Estimator (재귀적 지연추정기를 갖는 적응잡음제거 기법을 이용한 음성개선)

  • 강해동;배근성
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.7
    • /
    • pp.33-41
    • /
    • 1994
  • A single channel adaptive noise canceling (ANC) technique with a recursive time delay estimator (RTDE) is presented for removing effects of additive noise on the speech signal. While the conventional method makes a reference signal for the adaptive filter using the pitch estimated on a frame basis from the input speech, the proposed method makes the reference signal using the delay estimated recursively on a sample-by-sample basis. As the RTDEs, the recursion formulae of autocorrelation function (ACF) and average magnitude difference function (AMDF) are derived. The normalized least mean square (NLMS) and recursive least square (RLS) algorithms are applied for adaptation of filter coefficients. Experimental results with noisy speech demonstrate that the proposed method improves the perceived speech quality as well as the signal-to-noise ratio and cepstral distance when compared with the conventional method.

  • PDF

Shock Test Signal Analysis using Wavelets (웨이블렛을 이용한 충격신호분석)

  • 안호일
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.147-154
    • /
    • 2001
  • The underwater explosion shock test is performed for the evaluation of the shock-resistant capability which is a very critical factor considering the survivability of the battle ship. Some measured signals have impulsive noise and gaussian white noise because of the unstable power supply system and the transient movement of cables during the underwater explosion shock test. The advanced shock signal analysis method which remove the noise of measured signal using the threshold policy of the median filter and the orthogonal wavelet coefficients are proposed. It is verified that the signal-to-noise ratio was improved about 30㏈ by the numerical simulation.

  • PDF

A design of an improved GMSK quadrature modulator for digital cellular system (디지털 셀룰라 시스템을 위한 개선된 GMSK 직교 변조기의 설계)

  • 송영준;한영열
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.32-41
    • /
    • 1996
  • We propose the improved GMSK (gaussian-filtered minimum shift keying) quadrature modulator using the FIR(finite impulse response )filter whose coefficients are obtained form the differnce of phase response, and design its ASIC (applicaton specific integrated circuit) which can be used for GSM (global system for mobile communication) digital cellular system and DCS 1800 (digital cellular system at 1800MHz) personal communication system. Input data become quantized I and Q channel 10 bit signal through cosine and sine ROM mapping after being filtered by the FIR filter whose normalized bandwidth is 0.3 and designed by considering intersymbol interference as well as sampling ratio. These two signals become the GMSK modulated I and Q channel signal through DAC (digital-to-analog converter) and 7th order analog chebyshev LPF(low pass filter) respectively. The difference between the ideal analog signal and its digitized signal is analyzed in terms of sampling noise, quantization noise, truncation noise and coefficient noise. And the effect of the LPF following the DAC is considered. The ASIC design of the GMSK quadrature modulator is also confirmed by an experiment.

  • PDF

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

A Study on Estimation of Coefficient Using Wavelet Transform and Its Application to the Evaluation of Harshness in Passenger Car (웨이브렛 해석을 이용한 승용차의 충격 하쉬니스 개선)

  • Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1710-1715
    • /
    • 2000
  • Estimation of damping ratio for vibration signals measured on the passenger car's seat is useful for the objective evaluation of impact harshness in car. The vibration signal is a transient signal represented by many coupled modes of suspension system. Wavelet transform automatically decouples these modes in the time-frequency domain. Damping ratios for decoupled modes are obtained by logarithmic treatment for the Wavelet transformed signal. The objective evaluation using Wavelet transform has been well corresponded with subjective evaluation done by skilled engineers.

  • PDF