• Title/Summary/Keyword: Signal-injection

Search Result 396, Processing Time 0.028 seconds

Case Study of Intermittent Poor Acceleration Fault Diagnosis by Brake Switch Fault (브레이크 스위치 결함에 의한 간헐적인 가속불량 현상의 고장진단 사례연구)

  • Kim, Sung Mo;Jo, Haeng Deug
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.203-210
    • /
    • 2015
  • This paper investigates the failure of a car with a 2.5-liter CRDi engine of the Hyundai Company. The failure is caused by intermittent poor acceleration while driving. To analyze the cause, we investigated the air intake volume, the fuel injection, and the air-fuel ratio, which were determined to be normal. The brake switch signal error was discovered while analyzing the function that limits the output of the engine. While investigating the cause, we discovered the corrosion of the pins on the connector of the brake switch. We determined that it was generated by soapy water flowing in the solar film. Therefore, the cause of the failure was the brake switch signal errors. Additionally, we determined that ECM was the normal fail-safe mode that implemented the override device for safety during normal acceleration. Based on these results, further solar film experiments must be conducted to fully elucidate the causes.

Modulated Fuel Feedback Control of a Fuel Injection SI Engine (연료량 변조법에 의한 연료분사식 가솔린엔진의 공연비 제어)

  • 박경석;박진일;고상근;노승탁;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.102-111
    • /
    • 1996
  • For the air-fuel ratio control in a fuel injection SI engine, the Jump-Ramp control algorithm has been widely adopted by using the on/off type oxygen sensor. But the Jump-Ramp control method has limitation on treating the frequency and amplitude of the air-fuel ratio oscillation. This study suggests another feedback control logic named modulated fuel feedback control, which has a concept of pre-tuned air-fuel ratio oscillation. In the modulation method, the oxygen sensor output is not treated as on/off signal but as analog signal for feedback. By using the modulation method, the frequency and the amplitude of air-fuel ratio oscillation can be adjustable to some extent for improving the conversion efficiency of the Three-Way Catalyst. The result shows that the performance of the modulation method is better than that Jump-Ramp control method in reducing the amplitude of the air-fuel ratio oscillation as well as in increasing the frequency of the air-fuel ratio oscillation.

  • PDF

Low Noise Local Oscillator Design in K Band using Baseband Noise Upconversion Gain Analysis (저주파 잡음 상향 변화 이득 해석을 이용한 K 밴드 저잡음 국부 발진기의 설계)

  • 이영택;이문규;임종식;염인복;장동필;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.462-469
    • /
    • 2001
  • In this paper, local oscillator in K band using low frequency noise upconversion gain anaylsis was designed and measured. We extended Two Signal Method(TSM) to estimate upconversion gain and resulting phase noise. To confirm the validity of the proposed method, a free-running oscillator which had low upconversion gain was designed. The measured oscillation frequency was 23.42 GHz and phase noise at 1 MHz of offset was -105.2 dBc/Hz. Also, this oscillator was operated for subharmonic injection locked osci1lator(SILO). In this case, SILO showed ideal frequency multiplier phase noise characteristics at low subharmonic injection power level.

  • PDF

PD measuring on MV XLPE Calble by Using UWB Antenna (UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Lee, Yong-Sung;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine (LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구)

  • 오승묵;박승재;허환일;강건용;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

Chaos system control via discrete signals (이산 신호에 의한 카오스 시스템 제어)

  • 양기철;권세현;안기형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.147-150
    • /
    • 1997
  • In the study, we consider chua's circuit which is a paradigmatic chaotic system belonging to Lur'e form. It is shown that the dynamic behavior of such a system can be influenced in such a way as to obtain out of chaotic behavior a desired periodic orbit corresponding to an unstable periodic trajectory which exists in the system. This kind of control can be achieved via injection of a single continuous time signal representing the output of the system associated with an unstable periodic orbit embedded in the chaotic attractor We investigate the case when this signal is sampled, i.e. we supply to the system the control signal at discrete time moments only.

  • PDF

Leptin Is a Metabolic Signal for GnRH-LH/FSH Axis in Feed-restricted Ewes

  • Towhidi, A.;Khazali, H.;Zhandi, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.7
    • /
    • pp.1039-1048
    • /
    • 2007
  • Two experiments were conducted to determine whether leptin is a metabolic signal for gonadotropin secretion in ewes. In the first experiment, twenty-eight cyclic Chal ewes were assigned randomly to an energy restricted, no leptin group (ERNL) (60% of maintenance; n = 14) and an energy normal, no leptin group (ENNL) (100% of maintenance; n = 14) for 71 days (6 estrous cycles). Estrus was synchronized with seven consecutive injections of $PGF_{2{\alpha}}$ Biweekly, body weight (BW) and body condition score (BCS) were determined and blood samples were collected to measure plasma leptin concentration. Blood samples were also taken to determine plasma progesterone concentration twice weekly. After each PG injection from the second injection to the end of experiment, four ewes were selected and blood samples were collected at 20 minutes and at hourly intervals for 3 h to detect plasma LH and FSH concentration. In the second experiment, after the ceasing of the estrous cycle caused by energy restriction, six acyclic ewes were selected and randomly allotted to two groups (n = 3) and received the following treatment for four days. Ewes in an energy restricted, leptin group (ERL) were fed with a ration which provided 60% of maintenance energy requirements and intravenously injected with $4{\mu}g$ leptin/kg BW daily. Ewes in an energy excess, no leptin group (EENL) were fed with a ration that provided 180% (120%+60%) of maintenance energy requirements and intravenously injected with 1 ml saline daily. In both groups, blood samples were collected at 20 minutes and at hourly intervals for 3 h before feeding on d 0 and d 5, and for 3 h before and after injections as above on d 2 and d 4 to detect plasma LH and FSH concentration. In the first experiment, BW and BCS from the $2^{nd}$ estrous cycle, and leptin from the $3^{rd}$ estrous cycle to the end of the experiment significantly (p<0.05) decreased. In ERNL ewes, mean plasma concentrations of FSH significantly (p<0.01) decreased from the $4^{th}$ estrous cycle to d 71 and LH pulsatile secretion was suppressed on d 71, so that, mean plasma concentrations of LH (p<0.05), LH pulse frequency (p<0.01) and LH pulse amplitude (p<0.05) significantly decreased. In the second experiment, injection of leptin significantly increased mean circulating concentrations of LH (p<0.05), LH pulse frequency (p<0.01), LH pulse amplitude (p<0.05) and mean circulating concentrations of FSH (p<0.01) and leptin (p<0.01). High energy intake significantly (p<0.05) stimulated pulsatile secretion of LH and leptin secretion (p<0.01), but non-significantly increased plasma FSH concentration. The results of this study indicate that leptin is a metabolic signal for the GnRH-LH/FSH axis in feed-restricted fat-tailed ewes.

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

A bond graph approach to energy efficiency analysis of a self-powered wireless pressure sensor

  • Cui, Yong;Gao, Robert X.;Yang, Dengfeng;Kazmer, David O.
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.1-22
    • /
    • 2007
  • The energy efficiency of a self-powered wireless sensing system for pressure monitoring in injection molding is analyzed using Bond graph models. The sensing system, located within the mold cavity, consists of an energy converter, an energy modulator, and a ultrasonic signal transmitter. Pressure variation in the mold cavity is extracted by the energy converter and transmitted through the mold steel to a signal receiver located outside of the mold, in the form of ultrasound pulse trains. Through Bond graph models, the energy efficiency of the sensing system is characterized as a function of the configuration of a piezoceramic stack within the energy converter, the pulsing cycle of the energy modulator, and the thicknesses of the various layers that make up the ultrasonic signal transmitter. The obtained energy models are subsequently utilized to identify the minimum level of signal intensity required to ensure successful detection of the ultrasound pulse trains by the signal receiver. The Bond graph models established have shown to be useful in optimizing the design of the various constituent components within the sensing system to achieve high energy conversion efficiency under a compact size, which are critical to successful embedment within the mold structure.

CO Two-photon Laser Induced Fluorescence Measurements in High Temperature and Pressure Conditions (고온고압 조건에서 Two-Photon LIF를 이용한 CO 측정에 관한 연구)

  • Oh, Seung-Mook;Kim, Duk-Sang;Miles, Paul C.;Colban, Will F.
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Carbon monoxide (CO) is not only an important intermediate species in chemical reaction mechanisms of hydrocarbon fuel combustion, but also a crucial pollutant species emitted from automotive engines. To better understand the physical processes impacting CO emissions, the development of laser-based measurement techniques that can visualize in-cylinder CO distributions is desirable. Among these techniques, Laser-Induced Fluorescence (LIF) is a sensitive and species-selective detection technique capable of good spatial resolution. However, some technical matters such as deep UV excitation, severe pressure dependency of the LIF signal, and potential interference from other species have been major challenges for CO LIF application. This study is focused on investigating the feasibility of CO two-photon LIF in a direct-injection diesel engine operating at typical pressure and temperature conditions with commercial grade diesel fuel. Spectroscopic analysis shows that the CO fluorescence signal can be separated from $C_2$ Swan band or broadband fluorescence from PAHs when the signal is collected near 483 nm. The signal-to-noise ratio of CO LIF deteriorate rapidly as pressure is increased, following $P^{-1.49}$ which matches the theoretical signal pressure dependency.

  • PDF