• Title/Summary/Keyword: Signal to Noise

Search Result 6,382, Processing Time 0.041 seconds

Determination of Amitrole in Water Samples by Evaporation and GC/MS (증발법과 GC/MS를 이용한 수질 시료 중의 Amitrole의 분석법 연구)

  • Yoon, So Hee;Hong, Ji Eun;Pyo, Hee Soo;Park, Song Ja
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.483-487
    • /
    • 2003
  • Amitrole is well-known as a non-selective herbicide and it is able to cause contamination of driking water as well as pollution of ground water and surface water. However, it is difficult to extract from water because it has a high solubility for water whereas a low solubility for general organic solvents. This method is described for the determination of amitrole in water samples by GC/MS. After evaporation of 10 mL water sample by a vacuum evaporator, amitrole was derivatized with isobutyl chloroformate (iso-BCF) on room temperature for 15~20 min. As a result, the sensitivity for GCfMS was improved as N-isobutoxycarbonyl amitrole derivative was formed. The linearity of the calibration curve showed good as 0.997. The recoveries were obtained more than 94.9% and relative standard deviations were less than 2.8% at $1.0{\mu}g/L$, $10.0{\mu}g/L$ and $100.0{\mu}g/L$. The limit of detection showed $0.1{\mu}g/L$ with a signal-to-noise ratio (S/N) of 3.

Determination of alkylphenol ethoxylate in water by high performance liquid chromatography/electrospray ionization/mass spectrometry (HPLC/ESI/MS를 이용한 물 중의 알킬페놀에톡실레이트 분석)

  • Lee, Jeongae;Park, Song-Ja;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.263-270
    • /
    • 2004
  • A method is described for the analysis of short-chain alkylphenol ethoxylates (APEOs), 4-octylphenol-di-ethoxylate (OP2EO) and 4-nonylphenol-di-ethoxylate (NP2EO), in drinking water or wastewater using reversed phase high-performance liquid chromatography with electrospray ionization mass spectrometry. The solvent system was water and methanol containing $10{\mu}M$ trifluoroacetic acid as an ionization solvent. We acidified 1 L of water samples to less than pH 2 with concentrated $H_2SO_4$ and loaded onto Sep-Pak $C_{18}$, and eluted with acetone. The calibration of OP2EO and NP2EO was performed for the concentration range from 20 to 500 ng/L and the correlation coefficients were 0.999 and 0.990, respectively. The limits of detection were 20 ng/L (OP2EO) and 50 ng/L (NP2EO) at a signal-to-noise ratio of 3. Accuracy and precision of this analytical method were 85.8 ~ 122.1% and 8.2 ~ 18.8%, respectively. The proposed method allowed a sensitive and rapid detection of OP2EO and NP2EO and it could be applied for monitoring of APEOs from environmental samples.

Determination of tetracycline antibiotics in food (식품 중 테트라싸이클린계 항생물질의 분석)

  • Park, Dongmi;Jeong, Jiyoon;Chang, Moonik;Im, Moohyeog;Park, Kunsang;Hong, Mooki
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.250-256
    • /
    • 2005
  • A selective method of high performance liquid chromatography with UV detector has been applied to determine 4 tetracycline antibiotics in the animal food, simultaneously. The targets were chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC), and tetracycline (TC) that are used routinely in veterinary medicine for prevention and control of disease. Food samples were beef, pork, chicken, milk, whole egg, flatfish (Limanda yokohamae), jacopever (Sebastes hubbsi), seabream (Chrysophrys major), eel (Anguilla japonica) and lobster (Hommarus americanus). After extracting food samples with 20% trichloroacetic acid and McIlvaine buffer, they were purified by a $C_18$ SPE cartridge with 0.01M methanolic oxalic acid solution. The concentrated residue was re-dissolved in methanol, filtered, cleaned up and analyzed on a $C_18$ column. The mobile phase was a mixture of 0.01M oxalic acid and acetonitrile with a gradient ratio from 85:15 to 60:40. The UV wavelength was 365 nm. The overall recoveries were ranged from 71% to 98% and the limit of detections were 0.022 for CTC, 0.012 for DC and OTC and 0.009 mg/kg for TC at signal/noise > 3, respectively. As results, CTC, DC and TC were not detected in all selected food samples, however, OTC was detected in meat and fishes. The determined level of OTC was 0.04 ppm for pork, 0.17 ppm for flatfish and 0.05 and 0.08 ppm for jacopever, that were within the Maximum Residue Limits (MRLs) in the food.

$NO_{2}$ Sensing Properties of Oxide Semiconductor Thick Films (산화물 반도체형 후막 가스 센서의 이산화질소 감지 특성)

  • Kim, Seung-Ryeol;Yun, Dong Hyun;Hong, Hyung-Ki;Kwon, Chul-Han;Lee, Kyu-Chung
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.451-457
    • /
    • 1997
  • The thick films of oxide semiconductors such as $WO_{3}$, $SnO_{2}$ and ZnO for the $NO_{2}$ detection of sub-ppm range have been prepared and their characteristics were investigated. It is showed that the optimum operating temperatures of the sensors are $300^{\circ}C$ and $220{\sim}260^{\circ}C$ for $WO_{3}$-based and $SnO_{2}$-based thick films, and ZnO-based thick films, respectively. Since the resistance of ZnO-based thick films are extremely high($>10^{6}{\Omega}$), the signal to noise ratio was comparatively low. In order to determine the selectivity, the films are exposed to the interfering gases such as ozone, ammonia, methane and the mixture of carbon monoxide and propane. $WO_{3}$-ZnO(3 wt.%) and $SnO_{2}-WO_{3}$(3 wt.%) thick film sensors show high sensitivity, good selectivity, excellent reproducibility and the linearity of $NO_{2}$ concentration versus sensor resistance. The preliminary results clearly demonstrated that the sensor can be successfully applied for the detection of $NO_{2}$ in sub-ppm range.

  • PDF

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF

Video Replay by Frame Receive Order Relocation Method in the Wire and Wireless Network (유무선 네트워크에서 프레임 수신 순서 재할당 방법을 사용한 동영상 재생)

  • Kang, Dong-Jin;Kim, Dong-Hoi
    • Journal of Digital Contents Society
    • /
    • v.17 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • When video service is performed in simulation using NS-2(Network Simulation-2), the video replay is performed as the received frame order. In the existing video replay method based on the received frame order, as the frame orders of receiver and transmitter are different, the receiver buffer does not have the effect that the packets between the frames of transmitter buffer holds a regular size and packet dense and sparsity phenomenon in the receiver buffer is made by the irregular packet size due to the unpredictable reversed order of received partial frames. The above dense and sparsity phenomenon increases the probability of buffer overflow and underflow generation. To prevent these problems, the proposed frame receive order relocation method adds an extra replay buffer which rearranges the order of receive frame as the order of transmit frame, so it has the effect that the packets between the transmit frames keeps a regular size. Through the simulation using NS-2 and JSVM(Joint Scalable Video Model), the generation number of buffer overflow and underflow, and PSNR(Required Peak Signal to Noise Ratio) performance between the existing method and proposed method were compared. As a result, it was found that the proposed method would have better performance than the existing method.

Locating Microseismic Events using a Single Vertical Well Data (단일 수직 관측정 자료를 이용한 미소진동 위치결정)

  • Kim, Dowan;Kim, Myungsun;Byun, Joongmoo;Seol, Soon Jee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.64-73
    • /
    • 2015
  • Recently, hydraulic fracturing is used in various fields and microseismic monitoring is one of the best methods for judging where hydraulic fractures exist and how they are developing. When locating microseismic events using single vertical well data, distances from the vertical array and depths from the surface are generally decided using time differences between compressional (P) wave and shear (S) wave arrivals and azimuths are calculated using P wave hodogram analysis. However, in field data, it is sometimes hard to acquire P wave data which has smaller amplitude than S wave because microseismic data often have very low signal to noise (S/N) ratio. To overcome this problem, in this study, we developed a grid search algorithm which can find event location using all combinations of arrival times recorded at receivers. In addition, we introduced and analyzed the method which calculates azimuths using S wave. The tests of synthetic data show the inversion method using all combinations of arrival times and receivers can locate events without considering the origin time even using only single phase. In addition, the method can locate events with higher accuracy and has lower sensitivity on first arrival picking errors than conventional method. The method which calculates azimuths using S wave can provide reliable results when the dip between event and receiver is relatively small. However, this method shows the limitation when dip is greater than about $20^{\circ}$ in our model test.

Design of Experiment and Analysis Method for the Integrated Logistics System Using Orthogonal Array (직교배열을 이용한 통합물류시스템의 실험 설계 및 분석방법)

  • Park, Youl-Kee;Um, In-Sup;Lee, Hong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5622-5632
    • /
    • 2011
  • This paper presents the simulation design and analysis of Integrated Logistics System(ILS) which is operated by using the AGV(Automated Guided Vehicle). To maximize the operation performances of ILS with AGV, many parameters should be considered such as the number, velocity, and dispatching rule of AGV, part types, scheduling, and buffer sizes. We established the design of experiment in a way of Orthogonal Array in order to consider (1)maximizing the throughput; (2)maximizing the vehicle utilization; (3)minimizing the congestion; and (4)maximizing the Automated Storage and Retrieval System(AS/RS) utilization among various critical factors. Furthermore, we performed the optimization by using the simulation-based analysis and Evolution Strategy(ES). As a result, Orthogonal Array which is conducted far fewer than ES significantly saved not only the time but the same outcome when compared after validation test on the result from the two methods. Therefore, this approach ensures the confidence and provides better process for quick analysis by specifying exact experiment outcome even though it provides small number of experiment.

Development of X-ray Detector using Liquid Crystal with Front Light (전면광원(Front Light)을 적용한 액정 X선 검출기 개발)

  • Rho, Bong Gyu;Baek, Sam Hak;Kang, Seok Jun;Lee, Jong Mo;Bae, Byung Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.831-840
    • /
    • 2019
  • The X-ray detector by liquid crystal with front light was proposed and verified by a X-ray image. The proposed detector utilizes the visible light instead of the electric signal by transistor. Therefore, it shows low noise and can be fabricated at low cost. The liquid crystal detector uses the orientation change of the liquid crystal molecule by conductivity change of the photoconductive layer. We can get the X-ray image from the transmitted light through the liquid crystal. The X-ray dose was calibrated from the measured transmittance of the visible light after comparison to the reference transmittance curve of the liquid crystal. The amorphous Se was used for photo con ducting layer and parylene was used for the liquid crystal alignment instead of the conventional alignment layer which needs high-temperature process over 200℃. The proposed X-ray detector can decrease the X-ray dose by high sensitivity which was verified by simulation. After the fabrication of the X-ray detector, the X-ray image was obtained as a function of the bias voltage to the liquid crystal. 10 lines/mm resolution was obtained from the line pattern and we will apply it to the 17inch diagonal liquid crystal X-ray detector with 3π retardation.

Estimation of Significant Wave Heights from X-Band Radar Using Artificial Neural Network (인공신경망을 이용한 X-Band 레이다 유의파고 추정)

  • Park, Jaeseong;Ahn, Kyungmo;Oh, Chanyeong;Chang, Yeon S.
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.561-568
    • /
    • 2020
  • Wave measurements using X-band radar have many advantages compared to other wave gauges including wave-rider buoy, P-u-v gauge and Acoustic Doppler Current Profiler (ADCP), etc.. For example, radar system has no risk of loss/damage in bad weather conditions, low maintenance cost, and provides spatial distribution of waves from deep to shallow water. This paper presents new methods for estimating significant wave heights of X-band marine radar images using Artificial Neural Network (ANN). We compared the time series of estimated significant wave heights (Hs) using various estimation methods, such as signal-to-noise ratio (${\sqrt{SNR}}$), both and ${\sqrt{SNR}}$ the peak period (TP), and ANN with 3 parameters (${\sqrt{SNR}}$, TP, and Rval > k). The estimated significant wave heights of the X-band images were compared with wave measurement using ADCP(AWC: Acoustic Wave and Current Profiler) at Hujeong Beach, Uljin, Korea. Estimation of Hs using ANN with 3 parameters (${\sqrt{SNR}}$, TP, and Rval > k) yields best result.