• Title/Summary/Keyword: Signal stability

Search Result 899, Processing Time 0.029 seconds

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.1
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

Study on Small-signal Modeling and Controller Design of DC-DC Dual Active Bridge Converters (DC-DC Dual Active Bridge 컨버터의 소신호 모델링 및 제어기 설계에 관한 연구)

  • Lee, Won-Bin;Choi, Hyun-Jun;Cho, Jin-Tae;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.159-165
    • /
    • 2017
  • Small-signal modeling and controller design methodology are proposed to improve the dynamics and stability of a DC-DC dual active bridge (DAB) converter. The state-space average method has a limitation when applied to the DAB converter because its state variables are nonlinear and have zero average values in a switching period. Therefore, the small-signal model and the frequency response of the DAB converter are derived and analyzed using a generalized average method instead of conventional modeling methods. The design methodology of a lead-lag controller instead of the conventional proportional-integral controller is also proposed using the derived small-signal model. The accuracy and performance of the proposed small-signal model and controller are verified by simulation and experimental results with a 500 W prototype DAB converter.

A Study on Transmission Signal Design Using DAC to Reduce IQ Imbalance of Satellite-Mounted Synthetic Aperture Radar Transmitter (위성 탑재 영상레이다 송신기의 IQ 불균형 저감을 위한 DAC를 이용한 송신 신호 설계 기법에 관한 연구)

  • Lee, Young-Bok;Kang, Tae-Woong;Lee, Hyon-Ik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.144-150
    • /
    • 2022
  • The on-board processor of satellite synthetic aperture radar(SAR) generates transmission signal by digital signal processing, converts it into an analog signal. At this time, the transmission signal generated from the baseband requires the frequency modulation to convert it to the high-frequency band in order to improve the stability. General frequency modulation method using local oscillator(LO) causes IQ imbalance due to phase error/magnitude error and these error reduce performance of SAR. To generate transmission signal without phase/magnitude error, this paper suggests design method of the frequency modulation method using digital to analog converter(DAC) at on-board SAR. For design, this paper analyzes the characteristic of DAC mode and uses pre-compensation filter. To analyze the proposed method performance, performance index are compared with IQ imbalance signals. This method is suitable for on-board SAR using fast sampling DAC and has the advantage of being able to solve IQ imbalances.

Case study of microseismic techniques for stability analysis of pillars in a limestone mine (석회석 광산 내 광주의 안정성 분석을 위한 미소진동 계측기술의 현장적용)

  • Kim, Chang Oh;Um, Woo-Yong;Chung, So-Keul;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • This study deals with the case that was the field application of the microseismic monitoring techniques for the stability monitoring in a domestic mine. The usefulness and limitations of the microseismic techniques were examined through analyzing the microseismic monitored data. The target limestone mine adopted a hybrid room-and-pillar mining method to improve the extraction ratio. The accelerometers were installed in each vertical pillar within the test bed which has the horizontal cross-section $50m{\times}50m$. The measured signals were divided into 4 types; blasting induced signal, drilling induced signal, damage induced signal, and electric noise. The stability analysis was performed based on the measured damage induced signals. After the blasting in the mining section close to the test bed, the damage of the pillar was increased and rockfall near the test bed could be estimated from monitored microseismic data. It was possible to assess the pillar stability from the changes of daily monitored data and the proposed safety criteria from the accumulated monitored data. However, there was a difficulty to determine the 3D microseismic source positions due to the 2D local sensor arrays. Also, it was needed to use real-time monitoring methods in domestic mines. By complementing the problems encountered in the mine application and comparing microseismic monitored data with mining operations, the microseismic monitoring technique can be used as a better safety method.

Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.

Identification of Irradiated Crabs by ESR Spectrometry

  • Nam, Hye-Seon;Ly, Sun-Yung;Yang, Jae-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.1
    • /
    • pp.1-4
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity of irradiated crabs and the stability of these radicals under 9 weeks of storage. Swimming and small crabs were irradiated with doses of 0, 1, 3, 5 and 7 kGy using a Co-60 irradiator at ambient temperature. A claw, a walking leg and a cars- pace of the crab pieced and dried were placed in a resonant quart tube within an EPR X-band spectrometer. The irradiated crabs presented an asymmetric absorption in shape at g$_1$=2.002 $\pm$ 0.003 and g$_2$=1.998$\pm$0.005, and were different from the non-irradiated ones. The intensity of the ESR signals was greatest in the claw, intermediate in the carapace and lowest in the walking leg. Samples given low and high doses of irradiation could also be distinguished. The ESR signal after irradiation was stable, even after a 9-week storage.

  • PDF

Design of DSP based Depolarized Fiber Optic Gyroscope (DSP 기반의 비편광 광자이로스코프 설계)

  • Yoon, Yeong-gyoo;Joo, Min-sik;Kim, Yeong-jin;Kim, Jae-hyoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.153-156
    • /
    • 2009
  • The interferometric fiber optic gyroscopes (FOGs) are well known as sensors of rotation, which are based on Sagnac effect, and have been under development for a number of years to meet a wide range of performance requirements. This paper describes the development of open-loop FOG and digital signal processing techniques implemented on FPGA. Our primary goal was to obtain intermediate accuracy (pointing grade) with a good bias stability ($0.22^{\circ}/hr$) and scale factor stability, extremely low angle random walk ($0.07^{\circ}/\sqrt{hr}$) and significant cost savings by using a single mode fiber. A secondary goal is to design all digital FOG signal processing algorithms with which the SNR at the digital demodulator output is enhanced substantially due to processing gain. The CIC type of decimation block only requires adders and shift registers, low cost processors which has low computing power still can used in this all digital FOG processor.

  • PDF

A Design of Noise Reduction Circuit for A radio Telephonic System (무선전화 시스템용 잡음억제회로의 설계)

  • Moon, Jong-Kyu;Kim, Duk-Gyoo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.84-89
    • /
    • 2002
  • In this paper, we present the design method of noise reduction circuit in telephonic system. The circuit consists of compressor, expander and a filter. The basic idea of a proposed method compresses the audible signal in order to mask the channel noise during transmission and then expand at the reverse rate the transmitted signal to naturally recover the original signal. Of course, there should be no distortion or other degradation of the audio itself in passing through companding(compress/expand) cycle. In the compressing process, the gain of compressor is automatically controlled by the envelope level of input signal in order to increase the effective dynamic range of input signal and to improve the signal to noise ratio. The compressed rate is the root time of a audible signal. The compressed signal should be expanded at the square time of the signal to recover a original signal. Simulation shows the proposed method improves the performance of the noise reduction of a channel noise as well as stability. 

Relationship between Graft Appearance on Follow-up MRI and Knee Stability after Double Bundle ACL Reconstruction (이중 다발 전방십자 재건술 후 이식건의 자기공명영상 추시와 슬관절 안정성과의 관계)

  • Sim, Jae Ang;Kwak, Ji Hoon;Lee, Yong Seuk;Kim, Kwang Hui;Nam, Shin Woo;Jun, Sung Soo;Lee, Beom Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.128-133
    • /
    • 2012
  • Purpose: This study examined the relationship between graft appearance on follow-up magnetic resonance imaging (MRI) and knee stability after double bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: For each patient, 1.5 tesla MRI's were obtained. The signal intensity of grafts was divided into 3 grades by Sononda's classification. The course of grafts was divided into two patterns: straight and curved. We assessed Lachman test, KT 2000 arthrometer and anterior drawer stress radiograph using Telos$^{(R)}$ in $30^{\circ}$ knee flexion for anterior stability and evaluated pivot shift test for rotatory stability. The correlation between graft appearance on MRI and the results of knee stability tests was evaluated. Results: The anteromedial (AM) graft was evaluated as being grade 1 in 66.7%, grade 2 in 26.7%, and grade 3 in 6.7% of the cases and the posterolateal (PL) graft was assessed as being grade 1 in 63.3%, grade 2 in 33.3%, and grade 3 in 3.3% of the cases according to the signal intensity. The AM graft was evaluated as being straight in 83.3% and curved in 16.7% of the cases, and the PL graft was assessed as being straight in 86.7% and curved in 13.3% of the cases according to the course. The course of AM graft was correlated with the results of anterior stability tests and the course of PL graft was correlated with the result of rotatory stability test. However, the signal intensity of grafts was not correlated with the results of anterior stability and rotatory stability tests. Conclusion: The course of AM is correlated with anterior stability and the course of PL is correlated with rotatory stability on follow-up MRI after double bundle ACL reconstruction.

  • PDF