• 제목/요약/키워드: Signal failures

Search Result 91, Processing Time 0.032 seconds

A Study on the Failure Detection and Validation of Pressurizer Level Signal in Nuclear Power Plant (원전 가압기수위신호 고장검출 및 검증에 관한연구)

  • Oh, S.H.;Kim, D.I.;Zoo, O.P.;Chung, Y.H.;Lim, C.H.;Yun, W.Y.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.175-177
    • /
    • 1995
  • The sensor signal validation and failure detection system must be able to detect, isolate, and identify sensor degradation as well as provide a reconstruction of the measurements. In this study, this is accomplished by combining the neural network, the Generalized Consistency Checking(GCC), and the Sequential Probability Ratio Test(SPRT) method in a decision estimator module. The GCC method is a computationally efficient system for redundant sensors, while the SPRT provides the ability to make decisions based on the degradation history of a sensor. The methodology is also extended to the detection of noise degradation. The acceptability of the proposed method is demonstration by using the simulation data in safety injection accident of nuclear power plants. The results show that the signal validation and sensor failure detection system is able to detect and isolate a bias failure and noise type failures under transient conditions. And also, the system is able to provide the validated signal by reconstructing the measurement signals in the failure conditions considered.

  • PDF

Study on analog-based ex-core neutron flux monitoring systems of Korean nuclear power plants for digitization

  • Kim, Young Baik;Vista, Felipe P. IV;Chong, Kil To
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2237-2250
    • /
    • 2021
  • The analog-based Ex-core Neutron Flux Monitoring System (ENFMS) in Korean Nuclear Power Plants (NPPs) has been performing its intended functions successfully for a long time. On the other hand, the primary concern with the extended use of analog systems is the aging effect, such as mechanical failures, environmental degradation, and obsolescence. The transition to a digital-based Man-Machine Interface Systems (MMIS) in Korea and other countries has been accelerating, but some systems are still analog-based IC systems, such as the ENFMS in APR1400 NPPs. Digitalized ENFMS can become a reality using computers and microprocessors owing to the progress in digital electronics and information technology. This paper presents the result of the first phase of the research on the digitalization of the ENFMS signal processing electronics for NPPs operated or produced in Korea. It has two main parts: (1) review engineering bases of ex-core neutron flux monitoring system, including nuclear engineering, instrumentation techniques, and analog and digital signal processing techniques, and (2) analysis of analog signal processing electronics of ENFMS for OPR1000 and APR1400 power plants. They are prerequisite to the second phase of the research which is the detailed implementation of the digitalization.

A Stability Analysis of Bus Controller of Power Control Unit for GEO Satellite (정지궤도위성 전력조절장치 버스제어기 안정도해석)

  • Choi Jaedong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.874-877
    • /
    • 2004
  • This paper presents the bus controller analysis of a power control unit of GEO satellite with 3kW power output. The sensing error of bus voltage produce control signal of the shunt switch assembly and the battery power converter, and the tolerance of error signal generated decide the stability of proposed system. The worst case analysis considered for the initial tolerance, temperature effect, tolerance of end of life is peformed to verify a designed bus controller. And also, the stability of system proposed according to moving of zero and pole values by some component failures is analyzed.

  • PDF

Failure Forecast Diagnosis of Small Wind Turbine using Acoustic Emission Sensor

  • Bouno Toshio;Yuji Toshifumi;Hamada Tsugio;Hideaki Toya
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.78-83
    • /
    • 2005
  • Currently in Japan, the use of the small wind turbine is an upward trend. There are already many well established small wind turbine generators in use and their various failures have been reported. The most commonly sighted failure is blade damage. Thus the research purpose was set to develop a simple failure diagnostic system, where an Acoustic Emission (AE) signal was produced from the failure part of a blade which was measured by AE sensor. The failure diagnostic technique was thoroughly examined. Concurrently, the damage part of the blade was imitated, the AE signal was measured, and a FFT(Fast Fourier Transform) analysis was carried out, and was compared with the output characteristic. When one sheet of a blade was damaged 40mm or more, the level was computed at which failure could be diagnosed.

Design of Fault Location System for High Voltage Underground Power Cable (지중송전선 고장점 탐색 장치 설계)

  • Lee, Jae-Duck;Ryoo, Hee-Suk;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.603-605
    • /
    • 2006
  • To reduce inference of any power delivery failures in underground power cable, power system operators are trying to find effective way of finding fault location as soon as possible. But it is very difficult to find fault location exactly for underground power cable. We are developing fault location system for underground power cable which can detect its fault location exactly. This new system monitors current and voltage of underground power cable by using low voltage and current sensors and if there are any accidents, it records its transient signal. Fault location is calculated by analyzing recorded signal. To develop fault location system for power cable, we needed fault simulation system and we installed it physically and tested. In this rapers, we describe on describe of fault location system for underground power cable.

  • PDF

Research for Signal Analysis of 18Mn-5Cr Steel Generator Retaining Ring using Ultrasonic Wave (초음파를 이용한 18Mn-5Cr강 발전기 리테이닝 링의 신호분석에 관한 연구)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.65-70
    • /
    • 2010
  • Retaining rings are used to support the field winding end turns from the centrifugal force by the high speed of the field and these are the overstressed parts among the generator parts. There have been several retaining failures in Europe and America, all attributable to stress corrosion cracking in 18Mn-5Cr steel. Since then, each manufacture companies have developed a good 18Mn-5Cr steel in temperature, strength characteristic and it is used in many field now. From many findings and test results, we could conformed that the failure might be grown in the overstressed condition unrelated to the moisture particle.

A Feasibility Study on the Characterization of Incipient Insulator Failure for Distribution Fault Prediction (배전선로 고장예지를 위한 애자의 고장징후 특성에 관한 연구)

  • Shin, Jeong-Hoon;Kim, Tae-Won;Park, Seong-Taek;Kim, Chang-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.245-249
    • /
    • 1997
  • A feasibility study on the characterization of incipient insulator failure for distribution fault prediction is presented. In this study, real distribution data was collected and analyzed to isolate incipient failure signatures or parameters which were expected to show distinct behaviors before and after failure incident. Several signal analysis methods were applied to isolate the parameters and a new strategy of analysis, the event-date concept, was also applied to find a relationship between non-harmonic and high frequency signal activities and imminent insulator failures.

  • PDF

Design and Control of Interleaved Buck Converter in High Power Applications

  • Kwon, Soon-Kurl;Saha, Bishwajit
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.199-204
    • /
    • 2007
  • This paper presents design of interleave configured dc-dc converter for high power distributed power system applications. The multi channel interleaving buck converter with small inductance has proved to be suitable for micro-grid, requiring medium output voltages, high output currents and fast transient response. Integrated magnetic components are used to reduce the size of the converter and improve efficiency. Unlike conventional methods, the distributed approach requires no centralized control, automatically accommodates varying numbers of converter cells, and is highly tolerant of subsystem failures. A general methodology for achieving distributed interleaving is proposed, along with a specific implementation approach. The design and simulation verification of switching frequency 10 kHz system is presented with interleaved clocking of the converter cells. The simulation (simulated by PSIM 6.1) results corroborate the analytical predictions and demonstrate the tremendous benefits of the distributed interleaving approach.

  • PDF

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

A Study on the Improvement of the Domestic Maintenance Capability Development System of Military for Overseas Maintenance Items through the Case Study of Intermittent Failure of an Avionics (항전계통 간헐결함 사례 분석을 통한 군의 해외 정비품 국내정비능력 개발제도 개선방안 고찰)

  • Lee, Hoyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.68-75
    • /
    • 2018
  • A flare from an Air Force fighter was abnormally dispensed during the landing. To determine the cause of the abnormal dispensing, fracture analysis, signal analysis and reproduction experiments based on physics of failures were performed. The primary cause of the failure was analyzed to be due to an intermittent fault of an internal circuit card in the AN/ALE-40 chaff/flare dispenser by a broken lid of a capacitor, and the root cause which had derived the primary cause was considered to be an improper handling during the domestic maintenance which were changed from the overseas maintenance due to the DMSMS problem. Therefore, the overall process of the maintenance capability development system was reviewed and alternative ways that considers maintenance error decision aid(MEDA) for system improvement were suggested to prevent further failures.