• 제목/요약/키워드: Signal conditioning

검색결과 173건 처리시간 0.024초

배뇨력 측정을 통한 하부요로계의 보상성기능항진 평가 (Estimation of compensatory hypertrophy in lower urinary system using void force measurement)

  • 정도운;전계록
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.449-456
    • /
    • 2006
  • The purpose of urodynamic investigation is to obtain the information on the function of the urinary system. The aim of this study is to acquire the useful information of lower urinary tract symptom (LUTS) diagnosis through void force signal as noninvasive method. The system which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and void force during urination. The implemented system composes of the sensor parts, signal conditioning parts and PC monitoring program. For the evaluation of the implemented system, the simulation of control part of the system was performed and the model system for the lower urinary system was designed. The superiority of a measuring characteristic of the implemented system was verified using the model system. From the evaluation of the model system, we have found out that the void force was dependent on the occlusion degree and compensatory hypertrophy significantly.

128 채널 심장전기도 전치 증폭기의 설계 (The Design of 128 Channels Cardiac-Activation Pre-Amplifier)

  • 유선국;장병철;정동일;한영오
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권11호
    • /
    • pp.550-556
    • /
    • 2001
  • The computerized cardiac analysis system, which acquires and analyzes the electrical activation signal propagating along the surface of the heart, is indispensible equipment for the open heart surgery and electrical cardiac study. In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and isolation part. It has distinct features; high voltage protection, leakage current limitation, isolation and the maximization of common mode rejection ratio with respect to the half-cell potential difference due to different electrode materials. The final pre-amplifier circuit is assembled with 8 boards, each of which composing of 16 channels.

  • PDF

EOG 신호의 파형 감지를 위한 디지털 필터의 설계 및 왜형 해석 (Design and Distortion Analysis of Digital Filters for ECG Waveforms Detection)

  • 남현도;안동준;이철희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.70-73
    • /
    • 1993
  • Design as well as Distortion analysis of signal conditioning filters is very useful for practical applications. Distortion analysis of digital filters for wave forms detection in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing.

  • PDF

TMS320F28335 DSP를 이용한 화자독립 음성인식기 구현 (Implementation of a Speaker-independent Speech Recognizer Using the TMS320F28335 DSP)

  • 정익주
    • 산업기술연구
    • /
    • 제29권A호
    • /
    • pp.95-100
    • /
    • 2009
  • In this paper, we implemented a speaker-independent speech recognizer using the TMS320F28335 DSP which is optimized for control applications. For this implementation, we used a small-sized commercial DSP module and developed a peripheral board including a codec, signal conditioning circuits and I/O interfaces. The speech signal digitized by the TLV320AIC23 codec is analyzed based on MFCC feature extraction methed and recognized using the continuous-density HMM. Thanks to the internal SRAM and flash memory on the TMS320F28335 DSP, we did not need any external memory devices. The internal flash memory contains ADPCM data for voice response as well as HMM data. Since the TMS320F28335 DSP is optimized for control applications, the recognizer may play a good role in the voice-activated control areas in aspect that it can integrate speech recognition capability and inherent control functions into the single DSP.

  • PDF

다중채널 A/D 변환 데이터획득시스템의 개발 (A Multi-Channel A/D Data Acquisition System)

  • 박찬원;이민섭;반윤호
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.183-189
    • /
    • 2005
  • In precision instrumentation system, an A/D conversion of signal conditioning has some problems.; offset and drift errors with environmental situation. This paper suggested a development of the Multi-Channel A/D Data Acquisition System and a method of the evaluation and the temperature compensation for the A/D converters with the specific analog and digital circuit including the software. Also, we have designed a hardware and a software filters with smart algorithm for better signal processing of the proposed system. Software approach was adopted to obtain the stable data from A/D converter. As shown in our experimental works, the proposed system is expected to be used in the industrial field where a high precision measurement is required.

  • PDF

다기능 산소전극에 의한 산소투과특성 동시측정 (Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode)

  • 이동희;정진휘;유형풍;김태진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF

ECG신호의 잡음 제거를 위한 디지탈 필터의 시간 영역 해석 (Time Domain Analysis of Digital Filters for Noise Cancelling in ECG Signals)

  • 남현도;안동준;이철희
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권2호
    • /
    • pp.137-145
    • /
    • 1993
  • Time domain analysis as well as frequency domain analysis of signal conditioning filters is very useful for practical applications. Time domain analysis of digital filters for noise cancelling in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing. Band reject filters are applied to power line interference cancelling in ECG signals.

  • PDF

Modeling and Simulation for Level & Flow Control System Using Microcontroller

  • Unhavanich, Sumalee;Dumawipata, Teerasilapa;Tangsrirat, Worapong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.5-86
    • /
    • 2001
  • This work describes a design and implementation of the level & flow rate control system by using a single-chip microcontroller. The proposed model system is designed based on the use of the single-chip microcontroller 8031 with the EPROM emulator for programming the computer software. The microcontroller reaches the input level and flow signals from the level sensor and the turbine flowmeter, respectively, via the signal conditioning circuits and A/D converters in order to calculate the control signal. Moreover, the status of the process variable can easily be set up and controlled by program monitoring through the emulator, and can be graphically displayed on the computer screen. Experiment results were carried out which can be ...

  • PDF

3차원 가속도 센서와 DSP를 응용한 가상 악기 시스템 개발 (Development of a Virtual Instrument System Using 3-demensional Acceleration Sensors and Digital Signal Processor)

  • 이희승;손동관;노영해
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2006년도 학술대회 1부
    • /
    • pp.982-987
    • /
    • 2006
  • 고전의 관현악기에서부터 현대의 각종 전자악기까지, 인류는 그 문화와 시대의 변화에 따라 다양한 형태의 악기를 개발하고 활용하였다. 최근에는 전기전자 기술의 발달로 다양한 센서와 프로그램을 활용해서 여러 가지 음색과 효과를 내는 악기가 개발되고 있다. 그 중에서 사람의 움직임을 직접 감지해서 음악적 도구로 활용하는 기술이 주목 받고 있다. 이를 위해 터치 센서(touch sensor), 비젼 센서(vision sensor), 자기장 센서(magnetic sensor), 초음파 센서(ultrasonic sensor) 등이 응용되고 있다. 그러나 지금까지의 센서 기술로는 사람의 움직임과 관련된 위치, 속도, 가속도 등에 대한 정보를 직접 추출하기가 어렵고, 구현된 시스템도 공간의 제약을 받거나 혹은 구현된 부피가 크거나 복잡한 구성형태를 지니고 있는 문제점이 있었다. 그래서 본 논문에서는 사람의 움직임과 관련된 가속도 정보를 직접 감지해서 새로운 형태의 악기로 활용될 수 있는 시스템을 연구하고 개발하였다. 이를 위해 6개의 가속도 정보를 처리하는 기술과 DSP(Digital Signal Processor) 활용 기술, Max/MSP 활용 기술이 응용 되었으며, 소형의 시스템을 개발하기 위해 시그널 컨디셔닝(signal conditioning) 회로와 DSP 보드를 자체 개발하였다. 실험을 통해 사람의 움직임과 관련된 각종 정보가 적절한 소프트웨어의 활용으로 다양한 음색의 변화는 물론 음높이, 음량의 변화까지도 제어할 수 있음을 확인하였고, 새로운 형태의 악기로써 무대 공연이나 노래방 등에 폭넓게 활용될 수 있는 가능성을 확인하였다.

  • PDF

Real Time ECG Monitoring Through a Wearable Smart T-shirt

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.16-19
    • /
    • 2015
  • A wearable sensing ECG T-shirt for ubiquitous vital signs sensing is proposed. The sensor system consists of a signal processing board and capacitive sensing electrodes which together enable measurement of an electrocardiogram (ECG) on the human chest with minimal discomfort. The capacitive sensing method was employed to prevent direct ECG measurement on the skin and also to provide maximum convenience to the user. Also, low power integrated circuits (ICs) and passive electrodes were employed in this research to reduce the power consumption of the entire system. Small flexible electrodes were placed into cotton pockets and affixed to the interior of a worn tight NIKE Pro combat T-shirt. Appropriate signal conditioning and processing were implemented to remove motion artifacts. The entire system was portable and consumed low power compared to conventional ECG devices. The ECG signal obtained from a 24 yr. old male was comparable to that of an ECG simulator.