• 제목/요약/키워드: Signal Processing Unit

검색결과 350건 처리시간 0.03초

전달 시간차 방식 다회선 초음파 가스 유량계 개발 (Study on the Development of Multi-Path Ultrasonic Gas Flowmeter)

  • 황원호;박상국;이치환;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

모델화 채널필터에 대한 인버스필터링 (Inverse Filtering for a Modelling Channel Filter)

  • 김성호;주창복
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 하계종합학술대회논문집
    • /
    • pp.17-20
    • /
    • 2000
  • In a digital communication system, the transmission channel may introduce error into the digital signal being transmitted. It would be useful if a process could be devised so that the error could be removed in order to recover the transmitted digital signal. We design a corrective filter that is inverse filter, which will generate an output signal identical to the input signal. in order for two systems connected in cascade to produce an output which is identical to the input signal, the over-all unit sample response of the cascade connection must be a unit sample function.

  • PDF

신호를 한 개의 데이터로 함축하고 재생하는 알고리즘 실현에 관한 연구 (A Study on the Processing for Implication and Regeneration of Signal)

  • 송도선;손진우;이행세
    • 전자공학회논문지B
    • /
    • 제29B권8호
    • /
    • pp.7-14
    • /
    • 1992
  • This paper persents how the signal is expressed by an implied unit data and the implied unit data is regenerated into the original signal. This shows that the regenerated signal is equal or similar to the original signal depending on the number of chaos prediction. The algorithm quoted above is implemented from the signal composed of 30 data. This algorithm will be applied to the applied science of data communication: information storage, speech processing, CAD, character recognition, etc...

  • PDF

FMCW 레이더의 거리 및 속도 오차 향상을 위한 신호처리부 하드웨어 구조 제안 (Architecture of Signal Processing Unit to Improve Range and Velocity Error for Automotive FMCW Radar)

  • 현유진;이종훈
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.54-61
    • /
    • 2010
  • In this paper, we design the signal processing unit to effectively support the proposed algorithm for an automotive Frequency Modulation Continuous Wave(FMCW) radar. In the proposed method, we can obtain the distance and velocity with improved error depending on each range(long, middle, and short) of the target. Since a high computational capacity is required to obtain more accurate distance and velocity for target in near range, the proposed signal processing unit employs the time de-interleaving and the frequency interpolation method to overcome the limitation. Moreover, for real-time signal processing, the parallel architecture is used to extract simultaneously the distance and velocity in each range.

비행체 탑재 펄스 도플러 레이다 시험모델 개발 (Airborne Pulsed Doppler Radar Development)

  • 곽영길;최민수;배재훈;전인평;양주열
    • 한국항행학회논문지
    • /
    • 제10권2호
    • /
    • pp.173-180
    • /
    • 2006
  • 비행체 탑재 레이다는 기상에 관계없이 전천후로 비행체의 안전항행, 임무감시, 사격통제, 충돌회피, 이착륙 등 비행에 필수적인 항공장치이다. 본 논문에서는 비행체 탑재 다중 모드 펄스 도플러 레이다 시험 모델의 설계, 제작 및 비행시험 결과를 제시한다. 레이다 시스템은 안테나부, 송수신부, 신호처리부와 전시부의 4-LRU(Line Replacement Unit)로 구성되며, 개발기술은 평판 슬롯 배열 안테나, TWTA 송신기, coherent I/Q detector, 디지털 펄스 압축, 도플러 FFT 필터를 기반으로 한 DSP, 적응 CFAR, TWS 추적 처리기, 비행정보 IMU 및 도플러 추정보상 기법을 포함한다. 개발된 레이다 시스템의 설계 성능은 다양한 헬기탑재 비행시험을 통하여 기능 및 성능을 확인하였다.

  • PDF

반사된 국소화 표면 플라즈몬 공명 신호를 이용한 광섬유기반 바이오센서의 측정 신호처리 방법 (The Method of Measurement Signal Processing of Biosensor Based on Optical Fiber Using Reflected Localized Surface Plasmon Resonance)

  • 정현호;이승기
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2011
  • LSPR(Localized Surface Plasmon Resonance) sensor measures the refractive index change on the sensor surface. The detection of biological reaction with the unknown refractive index needs to be converted into the signal sensitivity for the refractive index change for comparison with other measurements. To find the signal sensitivity, the three steps of signal processing are proposed, which are signal modeling, signal calibration and signal normalization of LSPR sensor. The detected signal of biotin-streptavidin interaction has been converted into unit of [RU](Resonance Unit) using the proposed method. The converted signal directly can be compared with the other sensors including commercialized one.

가변 특성을 갖는 디지털 TV 휘도신호 처리용 디지털 필터 설계 (Design of a digital filter with variable characteristics for a luminance signal processing of digirtal TV)

  • 왕종현;이해정;유영갑;조경록
    • 한국통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.67-79
    • /
    • 1996
  • This paper presents a composite luminance signal processing system for NTSC, PAL and SECAM standards. Eaxh of the three standards employs its own specifications of subcarmier bandwidth and luminance signal waveform. The proposed system, compatible to the specifications of the three standard and B/W TV, implements variable freqneucy characteristics by controlling filter coefficients. The major features of the system are a luminance/chroma separation unit and an aperture compensation unit. The luminance/chroma separation unit employes a notch filter selection a trap freqneyc to atenuate unwanted color signals in luminance signal bands. The aperture compensation unit comprises two subunits, to provide clear color definition for each of the three standards: a primary compensation circuit and a variable compensation circuits. The proposed system yields a 40 dB gain from the chroma/luminance separation and a 10 dB gain from the aperture compensation unit.

  • PDF

Software-based Real-time GNSS Signal Generation and Processing Using a Graphic Processing Unit (GPU)

  • Im, Sung-Hyuck;Jee, Gyu-In
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제3권3호
    • /
    • pp.99-105
    • /
    • 2014
  • A graphic processing unit (GPU) can perform the same calculation on multiple data (SIMD: single instruction multiple data) using hundreds of to thousands of special purpose processors for graphic processing. Thus, high efficiency is expected when GPU is used for the generation and correlation of satellite navigation signals, which perform generation and processing by applying the same calculation procedure to tens of millions of discrete signal samples per second. In this study, the structure of a GPU-based GNSS simulator for the generation and processing of satellite navigation signals was designed, developed, and verified. To verify the developed satellite navigation signal generator, generated signals were applied to the OEM-V3 receiver of Novatel Inc., and the measured values were examined. To verify the satellite navigation signal processor, the performance was examined by collecting and processing actual GNSS intermediate frequency signals. The results of the verification indicated that satellite navigation signals could be generated and processed in real time using two GPUs.

5G 광중계기 구동을 위한 디지털 송수신 유닛 설계 (Development of Digital Transceiver Unit for 5G Optical Repeater)

  • 민경옥;이승호
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.156-167
    • /
    • 2021
  • 본 논문에서는 5세대 이동통신 네트워크 서비스의 커버리지를 확장하고, 빌딩내에서의 안정적인 무선 네트워크 연결해 주는 5G 광중계기의 인빌딩용 디지털 송수신 유닛 설계를 제안한다. 제안된 5G 광중계기 구동을 위한 디지털 송수신 유닛은 신호처리부, RF 송수신부, 광입출력부, 클록발생부 등의 4개 블록으로 구성된다. 신호처리부는 CPRI 인터페이스의 기본 동작과 4채널 안테나 신호의 조합 및 외부에서의 제어 명령에 대한 응답 등 중요한 역할을 수행한다. 또, JESD204B 인터페이스로 고품질의 IQ 데이터를 송수신 한다. 파워 앰프를 보호하기 위해 CFR, DPD 블록이 동작한다. RF 송수신부는 안테나로부터 수신된 RF 신호를 AD 변환하여 JESD204B 인터페이스로 신호처리부에 전달되고, 신호처리부에서 JESD204B 인터페이스로 전달된 디지털 신호를 DA 변환하여 안테나로 RF 신호를 송신한다. 광입출력부는 전기신호를 광신호로 변환하여 송신하고, 광신호를 전기신호로 변환하여 수신한다. 클록발생부는 광입출력부의 CPRI 인터페이스에서 공급되는 동기 클록의 지터(Jitter)를 억제하고, 신호처리부와 RF 송수신부에 안정적인 동기 클록을 공급한다. CPRI 연결전에는 로컬 클록을 공급하여 CPRI 연결 준비 상태로 동작한다. 본 논문에서 제안된 5G 광중계기 구동을 위한 디지털 송수신 유닛의 정확성을 평가하기 위해서 Xilinx 사의 MPSoC 계열의 XCZU9CG-2FFVC900I를 사용하였고 설계 툴은 Vivado 2018.3을 사용하였다. 본 논문에서 제안된 5G 광중계기 디지털 송수신 유닛이 ADC로 입력되는 5G RF 신호를 디지털로 변환하여 CPRI를 통해 JIG로 전달하는 Uplink 동작과 JIG로부터 CPRI를 통해 전달받은 Downlink 데이터 신호를 DAC로 출력하는 기능과 성능을 평가하였다. 실험결과는 평탄도, Return Loss, Channel Power, ACLR, EVM, Frequency Error 등이 목표로 한 설정 값 이상의 성능이 나타남을 확인 할 수 있었다.

생체신호 측정 및 종합관리 시스템 (SiMACS) (Biological Signal Measurement, Archiving, and Communication System (SiMACS))

  • 우응제;박승훈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF