• Title/Summary/Keyword: Signal Location

Search Result 1,296, Processing Time 0.025 seconds

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.

RFID Tag Search Protocol Preserving Privacy of Reader Holders (이동형 리더 소지자의 프라이버시를 보호하는 RFID 태그 검색 프로토콜)

  • Chun, Ji-Young;Hwang, Jung-Yeon;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.5
    • /
    • pp.59-69
    • /
    • 2009
  • RFID tag search system which is used to find a specific tag has an application such as asset management, supply chain, and this search scheme has been given much attention so far. In RFID tag search system, especially, mobility of the reader is important in order to search tags. Therefore, even though the handheld reader cannot connect with the central database because of unreliable wireless connection or remote location, handheld reader should search the specific tag without help of the central database. In addition, in RFID tag search system, users hold not the tag but the reader, the privacy of users should be considered. Since the signal strength of the reader is stronger than that of the tag, the privacy of the reader holder is very important. Recently, in order to solve these problems, a number of RFID tag search schemes have been proposed. However, since these schemes did not consider the privacy of reader holders, there are serious privacy breaches of reader holders. In this paper, we propose efficient RFID tag search protocol for passive tags. Our proposed scheme preserves the privacy of reader holders.

Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship (시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1044-1053
    • /
    • 2022
  • Time domain reflectometry (TDR) is a diagnostic technique to evaluate the physical integrity of cable and finds application in leak detection and localization of piping system. In this study, a cable-shaped leak detection sensor was proposed using the TDR technique for monitoring leakage detection of ship's engine room seawater piping system. The cable sensor was developed using a twisted pair arrangement and wound by an absorbent material. The availability and performance of the sensor for leak detection and localization were evaluated on a lab-scale pipeline set up. The developed sensor was installed onto the pipes and flanges of the lab-scale set up and various TDR waveforms were acquired and analyzed according to the dif erent variables including the number of twists and sheath thickness. The result indicated that the twisted cable sensor was able to produce clear and smooth signal as compared to the TDR sensor with a parallel arrangement. The optimal number of twist was determined to be above 10 per the unit length. The optimal diameter of sheath thickness that results in the desired sensitivity was determined to be ranging from 80% up to 120% of the diameter of the conductor. The linear regression analysis for estimation of leak localization was carried out to estimate the location of the leakage, and the result was a determination coefficient of 0.9998, indicating a positive relationship with the actual leakage point. The proposed TDR based leak detection method appears to be an effective method for monitoring leakage of ship's seawater piping system.

A Discussion on Image Analysis in 18F-Florbetaben PET/CT (18F-Florbetaben PET/CT 검사에서 영상분석에 대한 고찰)

  • Choi, Yong-Hoon;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.33-37
    • /
    • 2022
  • Purpose 18F-Florbetaben (FBB) Readings are made by visually comparing the signal strengths of gray matter and white matter. We intend to evaluate the usefulness of image analysis by comparing quantified image analysis with readout. Materials and Methods Based on the reading results, 100 patients were divided into a negative scan and a positive scan, and 300 MBq of FBB was injected, and images were taken 90 minutes later for 20 minutes. The equipment was a Discovery 600 (GE Healthcare, MI, USA). Four regions of interest (lateral temporal lobes, frontal lobes, posterior cingulate & precuneus, and parietal lobes) were established based on the amyloid reading standard provided by the manufacturer. For image analysis, SUVratio (SUVr) was calculated by dividing each SUVmean by the cerebellum, and the average SUVr in the entire area was performed. Statistical analysis analyzed the cutoff derivation through ROC Curve, the difference between groups in Independent sample t-test, and the degree of agreement with the reading result through Kappa test. Results The average SUVr cutoff in the entire area was 1.23. Concordance with the read results using cutoff was 95/100 (95%) for negative and 92/100 (92%) for positive. As a result of the t-test, there was a statistically significant difference between the groups (P < 0.05), and the Kappa statistical result showed a high degree of agreement with 0.867 (P < 0.05). Conclusion The results of image analysis were statistically significant and showed a high degree of agreement with the reading results. In addition, FBB image analysis can be viewed by 3D mapping the area where amyloid is accumulated, location estimation is possible, and quantitative analysis results can be viewed in detail. If quantified FBB image analysis is used as an auxiliary indicator, it is thought to be helpful in reading.

Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy (근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.405-410
    • /
    • 2022
  • In brachytherapy, a radiation source is inserted into the body to kill tumor tissue. Therefore, it is important to accurately measure the location of the source and the dose distribution. In this study, a dosimeter that can be used for brachytherapy was developed using CsPbBr3 which is cheaper than the existing detector materials and has a simpler manufacturing process. The CsPbBr3 dosimeter performance was evaluated by analyzing reproducibility, linearity, and distance dependence in 192Ir source. As a result of reproducibility evaluation, the RSD was 1.36%, which satisfies the standard value of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the standard R2 of 0.9990. The distance dependence evaluation showed a signal value that decreased exponentially as the distance increased. The evaluation results show that the CsPbBr3 dosimeter satisfies the evaluation criteria and can be used as a brachytherapy quality assurance dosimeter.

A study on the development of surveillance system for multiple drones in school drone education sites (학내 드론 교육현장의 다중드론 감시시스템 개발에 관한 연구)

  • Jin-Taek Lim;Sung-goo Yoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.697-702
    • /
    • 2023
  • Recently, with the introduction of drones, a core technology of the 4th industrial revolution, various convergence education using drones is being conducted in school education sites. In particular, drone theory and practice education is being conducted in connection with free semester classes and career exploration. The drone convergence education program has higher learner satisfaction than simple demonstration and practice education, and the learning effect is high due to direct practical experience. However, since practical education is being conducted for a large number of learners, it is impossible to restrict and control the flight of a large number of drones in a limited place. In this paper, we propose a monitoring system that allows the instructor to monitor multiple drones in real time and learners to recognize collisions between drones in advance when multiple drones are operated, focusing on education operated in schools. The communication module used in the experiment was equipped with GPS in Murata LoRa, and the server and client were configured to enable monitoring based on the location data received in real time. The performance of the proposed system was evaluated in an open space, and it was confirmed that the communication signal was good up to a distance of about 120m. In other words, it was confirmed that 25 educational drones can be controlled within a range of 240m and the instructor can monitor them.

A channel parameter-based weighting method for performance improvement of underwater acoustic communication system using single vector sensor (단일 벡터센서의 수중음향 통신 시스템 성능 향상을 위한 채널 파라미터 기반 가중 방법)

  • Kang-Hoon, Choi;Jee Woong, Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.610-620
    • /
    • 2022
  • An acoustic vector sensor can simultaneously receive vector quantities, such as particle velocity and acceleration, as well as acoustic pressure at one location, and thus it can be used as a single input multiple output receiver in underwater acoustic communication systems. On the other hand, vector signals received by a single vector sensor have different channel characteristics due to the azimuth angle between the source and receiver and the difference in propagation angle of multipath in each component, producing different communication performances. In this paper, we propose a channel parameter-based weighting method to improve the performance of an acoustic communication system using a single vector sensor. To verify the proposed method, we used communication data collected from the experiment conducted during the KOREX-17 (Korea Reverberation Experiment). For communication demodulation, block-based time reversal technique which is robust against time-varying channels were utilized. Finally, the communication results showed that the effectiveness of the channel parameter-based weighting method for the underwater communication system using a single vector sensor was verified.

Kidney Tumor Segmentation through Semi-supervised Learning Based on Mean Teacher Using Kidney Local Guided Map in Abdominal CT Images (복부 CT 영상에서 신장 로컬 가이드 맵을 활용한 평균-교사 모델 기반의 준지도학습을 통한 신장 종양 분할)

  • Heeyoung Jeong;Hyeonjin Kim;Helen Hong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.5
    • /
    • pp.21-30
    • /
    • 2023
  • Accurate segmentation of the kidney tumor is necessary to identify shape, location and safety margin of tumor in abdominal CT images for surgical planning before renal partial nephrectomy. However, kidney tumor segmentation is challenging task due to the various sizes and locations of the tumor for each patient and signal intensity similarity to surrounding organs such as intestine and spleen. In this paper, we propose a semi-supervised learning-based mean teacher network that utilizes both labeled and unlabeled data using a kidney local guided map including kidney local information to segment small-sized kidney tumors occurring at various locations in the kidney, and analyze the performance according to the kidney tumor size. As a result of the study, the proposed method showed an F1-score of 75.24% by considering local information of the kidney using a kidney local guide map to locate the tumor existing around the kidney. In particular, under-segmentation of small-sized tumors which are difficult to segment was improved, and showed a 13.9%p higher F1-score even though it used a smaller amount of labeled data than nnU-Net.

Imaging of Sequestered Lumbar Discs (요추 분리추간판의 영상 소견)

  • Gangwon Jeong;Heecheol Park;Sun Joo Lee;Dae-Hyun Park;Sung Hwa Paeng;Eugene Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.3-23
    • /
    • 2024
  • Intervertebral disc herniation is frequently encountered in radiological practice. Sequestered disc herniation occurs when the disc material undergoes degeneration and completely loses continuity with the parent nucleus pulposus. Sequestered discs can reside within and outside the spinal canal, exerting a mass effect on adjacent structures, compressing nerve pathways, and eliciting a range of clinical symptoms. In particular, sequestered discs within the dura cannot be identified without durotomy. Therefore, precise preoperative localization is crucial for surgical planning. On MRI, the signal intensity of the sequestered disc may vary due to independent degeneration processes. Additionally, most sequestered disc fragments show varying degrees of peripheral enhancement depending on the degree of angiogenesis and granulation around the isolated tissue. In this article, we review various imaging findings and the location of the sequestered disc to provide patients with an accurate diagnosis and appropriate treatment direction.

Implementation of A Vibration Notification System to Support Driving for Drivers with Cognitive Delay Impairment

  • Gyu-Seok Lee;Tae-Sung Kim;Myeong-Chul Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.4
    • /
    • pp.115-123
    • /
    • 2024
  • In this paper, we propose a vibration notification system that combines navigation information and wearable bands to ensure safe driving for the transportation vulnerable. This system transmits navigation driving information to a linked application, converts it into a vibration signal, and provides notifications through a wearable band. Existing navigation systems focus on providing route guidance and location information, so the driver's concentration is dispersed, and safety and convenience are deteriorated, especially for those with mobility impairments, due to standard vision and delayed recognition of stimuli, resulting in an increasingly high traffic accident rate. To solve this problem, navigation driving information is converted into vibration signals through a linked application, and vibration notifications for events, left turns, right turns, and speeding are provided through a wearable band to ensure driver safety and convenience. In the future, we will use cameras and vehicle sensors to increase awareness of safety inside and outside the vehicle by adding a function that provides notifications with vibration and LED when the vehicle approaches or recognizes an object, and we will continue to conduct research to build a safer driving environment. plan.