• Title/Summary/Keyword: Signal Factor

Search Result 1,835, Processing Time 0.024 seconds

A Study on the grinding factor affecting the AE Source in surface grinding (평면연삭에 있어서 AE발생원에 영향을 미치는 연삭인자에 관한 연구)

  • Han, Eung-Kyo;Kim, Ki-Choong;Kim, Koung-Suk;Kwon, Dong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.2
    • /
    • pp.55-61
    • /
    • 1986
  • The study is concerned with the investigation of grinding factor affecting the AE Source by means of the relation between the amplitude level of AE signal and the depth of wheel engagement in surface grinding by AE method. As the result, work velocity was confirmed that the amplitude of AE signal had almost constant value in comparison with the depth of wheel engagement. But the depth of wheel engagement and the width of wheel engagement were proportional to the amplitude of AE signal. Therefore, when the AE Source was classified by 3-zone, Ws and Wf were affected by the depth of wheel engagement and that Wr was affected by the width of wheel engagement. Also, the adaptability of the AE method was studied about the detection of tool life of grinding wheel, sparkout and initial contact point.

  • PDF

Functional Identification of a Nuclear Localization Signal of MYB2 Protein in Giardia lamblia

  • Kim, Juri;Shin, Mee Young;Park, Soon-Jung
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.675-679
    • /
    • 2020
  • MYB2 protein was identified as a transcription factor that showed encystation-induced expression in Giardia lamblia. Although nuclear import is essential for the functioning of a transcription factor, an evident nuclear localization signal (NLS) of G. lamblia MYB2 (GlMYB2) has not been defined. Based on putative GlMYB2 NLSs predicted by 2 programs, a series of plasmids expressing hemagglutinin (HA)-tagged GlMYB2 from the promoter of G. lamblia glutamate dehydrogenase were constructed and transfected into Giardia trophozoites. Immunofluorescence assays using anti-HA antibodies indicated that GlMYB2 amino acid sequence #507-#530 was required for the nuclear localization of GlMYB2, and this sequence was named as NLSGlMYB2. We further verified this finding by demonstrating the nuclear location of a protein obtained by the fusion of NLSGlMYB2 and G. lamblia glyceraldehyde 3-phosphate dehydrogenase, a non-nuclear protein. Our data on GlMYB2 will expand our understanding on NLSs functioning in G. lamblia.

2048-point Low-Complexity Pipelined FFT Processor based on Dynamic Scaling (동적 스케일링에 기반한 낮은 복잡도의 2048 포인트 파이프라인 FFT 프로세서)

  • Kim, Ji-Hoon
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.697-702
    • /
    • 2021
  • Fast Fourier Transform (FFT) is a major signal processing block being widely used. For long-point FFT processing, usually more than 1024 points, its low-complexity implementation becomes very important while retaining high SQNR (Signal-to-Quantization Noise Ratio). In this paper, we present a low-complexity FFT algorithm with a simple dynamic scaling scheme. For the 2048-point pipelined FFT processing, we can reduce the number of general multipliers by half compared to the well-known radix-2 algorithm. Also, the table size for twiddle factors is reduced to 35% and 53% compared to the radix-2 and radix-22 algorithms respectively, while achieving SQNR of more than 55dB without increasing the internal wordlength progressively.

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

Design Methodologies of High-speed Communication System with Signal Integrity (고속통신시스템의 신호충실성을 고려한 신호경로 설계 방법)

  • 박종대;박영호;남상식
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.279-282
    • /
    • 2000
  • As digital systems continue to use components with faster edge rates and clock speeds, transmission of the digital information in these systems approaches the microwave realm. At these speeds digital signal fidelity becomes both a critical success factor and design challenge. The noise sources in digital systems include the noise in power supply, ground and packaging media due to simultaneous switching of drivers, signal reflections and distortions on single and multiple transmission lines. This paper presents theory, case studies and design considerations of gigabit interconnection for network and communication systems. The case studies show HSPICE and Ampredictor simulations of alternate approaches. Various subjects including skin effect and dielectric losses, interconnect simulations and crosstalks of connector, affected signal discontinuity, are addressed.

  • PDF

Shock Test Signal Analysis using Wavelets (웨이블렛을 이용한 충격신호분석)

  • 안호일
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.147-154
    • /
    • 2001
  • The underwater explosion shock test is performed for the evaluation of the shock-resistant capability which is a very critical factor considering the survivability of the battle ship. Some measured signals have impulsive noise and gaussian white noise because of the unstable power supply system and the transient movement of cables during the underwater explosion shock test. The advanced shock signal analysis method which remove the noise of measured signal using the threshold policy of the median filter and the orthogonal wavelet coefficients are proposed. It is verified that the signal-to-noise ratio was improved about 30㏈ by the numerical simulation.

  • PDF

The Estimation Algorithm Design of Hall Sensor Signal Considering Safety of BLDC Motor (브러시리스 직류전동기의 안전성을 고려한 Hall Sensor 신호 추정 알고리즘 설계)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1894-1899
    • /
    • 2016
  • In this paper, because the position sensor represents the important factor in BLDC (Brushless DC) motor drives, BLDC motor is necessary that the three Hall-sensors evenly be distributed around the stator circumference in case of the 3 phase motor. The Hall-sensor is set up in this motor to detect the main flux from the rotor. So the output signal from Hall-sensor is used to drive IGBT to control the stator winding current. However, in case of breakdown Hall sensor, we research that the estimation algorithm of Hall sensor signal to detect rotor position and for the speed feedback signals with BLDC motor whose six stator and two rotor designed. In addition, this paper presents a sensorless speed control of BLDC Motor using terminal voltage of the one phase. Rotor position information is extracted by indirectly sensing the back EMF from only one of the three terminal voltages for a three-phase BLDC motor.

Development of an EEG and EP Mapping System based on the Graphical User Interface and Machine Automation (Graphical User Interface 및 자동화에 기초를 둔 뇌파 및 뇌 유발 전위 진단 시스템)

  • Kim, I.Y.;Lee, T.Y.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.81-84
    • /
    • 1994
  • A clinically oriented EEG and EP mapping system was developed with user-friendly interface and easy interactive operations. The system was based on the graphical user interface developed with C/C++ and Software Development Kit (SDK) operated under Microsoft Windows 3.1. Continuous acquisition for the EEG signal and burst mode acquisition for EEG signal syncronized to the external stimuli arc implemented with real time display. A neural network based automatic artifact discrimation is developed and implemented with which examination time can be reduced by a factor of 3 or more. Several bands of spectral maps and spectrums arc displayed for EEG diagnosis. Amplitude maps of EP signal at specified times by operator are displayed together with cine mode of EP maps for dynamic study. Source localization and other statistical signal processing are also included.

  • PDF

Involvement of protein tyrosine phosphatases in adipogenesis: New anti-obesity targets?

  • Bae, Kwang-Hee;Kim, Won Kon;Lee, Sang Chul
    • BMB Reports
    • /
    • v.45 no.12
    • /
    • pp.700-706
    • /
    • 2012
  • Obesity is a worldwide epidemic as well as being a major risk factor for diabetes, cardiovascular diseases and several types of cancers. Obesity is mainly due to the overgrowth of adipose tissue arising from an imbalance between energy intake and energy expenditure. Adipose tissue, primarily composed of adipocytes, plays a key role in maintaining whole body energy homeostasis. In view of the treatment of obesity and obesity-related diseases, it is critical to understand the detailed signal transduction mechanisms of adipogenic differentiation. Adipogenic differentiation is tightly regulated by many key signal cascades, including insulin signaling. These signal cascades generally transfer or amplify the signal by using serial tyrosine phosphorylations. Thus, protein tyrosine kinases and protein tyrosine phosphatases are closely related to adipogenic differentiation. Compared to protein tyrosine kinases, protein tyrosine phosphatases have received little attention in adipogenic differentiation. This review aims to highlight the involvement of protein tyrosine phosphatases in adipogenic differentiation and the possibility of protein tyrosine phosphatases as drugs to target obesity.

Design of an Adaptive Noise Canceller for the Motion Artifact Removal of a Pulse Oximetry Signal (펄스 옥시미터의 동잡음 제거 필터 설계)

  • Kim, Do-Young;Kim, Ill-Hwan
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.89-93
    • /
    • 2006
  • Pulse oximetry, which monitors non-invasively the oxygen saturation in blood, is influenced by patient's respiration, movement or a factor of an environment. Specially, it's difficult to measure a PPG (Photoplethsmography) signal from the moving patient because of the motion artifact. Accordingly, it is required to extract the pure PPG signal from the PPG signal to measure oxygen saturation. In this paper, we propose an adaptive noise canceller to improve the performance of motion artifact removal. Then we design a hardware system for real time monitoring of the oxygen saturation. The proposed algorithm estimates the slope of transition rate between two different wavelength signals.

  • PDF