• Title/Summary/Keyword: Signal Evaluation

Search Result 1,921, Processing Time 0.031 seconds

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

Comparison of peripheral vascular compliance between normal and diabetic group using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Kang, Eun-Seok;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.67-69
    • /
    • 2007
  • Recently, the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and diabetic group vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy is statistically lower than the normal group(p<0.05). We suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

  • PDF

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

Research on the Performance of Protocols and the Evaluation Metric for VIDEO Transmissions in an Ad Hoc Network

  • Chen, Ruey-Shin;Chao, Louis R.;Chen, Ching-Piao;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.10 no.1
    • /
    • pp.115-126
    • /
    • 2009
  • Video transmission effectiveness in the Ad Hoc network is becoming important recently, if different routing protocols are applied. Some researchers conclude that the reactive protocols are better for file transfer protocol (FTP) and constant bit rate (CBR) or hypertext transfer protocol (HTTP) transmission in an Ad Hoc wireless network but the performance report of video transmission is not much. This study adopts Qualnet (Network Simulator) as a simulation tool for environmental designing and performance testing, and employs an experimental design with eight groups. Our experiment shows that: (1) The performance of AODV (reactive) protocol is better than DSDV, ZRP and DSR when the transmission load has only one video stream; (2) Proactive (DSDV) and Hybrid protocols (ZRP) are better for a smaller Ad Hoc network when it transmits a video stream with some applications (VoIP, FTP and CBR). We conclude that packet loss rate is sensitive to the quality of video transmission and it has negative relationship with Peak Signal-to-Noise Ratio (PSNR) value. In addition, our experiment also shows that PSNR is a simple Metric for the performance evaluation of video transmission.

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Nondestructive Evaluation of the Defects in Composite-sintered Bushes Using Ultrasonics

  • Im, Kwang-Hee;Kim, Ki-Youl;Shin, Ki-Taek;Lee, Han-Hee;Jung, Il-Woong;Kang, To;Cho, Hyun-Joon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.1013-1017
    • /
    • 2012
  • Advanced composite-sintered bushings are widely utilized in the areas of excavators and injection molding machines as a journal bearing. Since the bearings are mainly used under high loads, service life should be long and the stored oil of inner bushings has to be continually fed into the bearing. The composite-sintered bushings are consisted of the two different materials; outer steel materials and inner porous sintered materials respectively. High temperature diffusion bonding has been applied for holding the both materials of the bushing together. Therefore, it is very important that the bonding reliability has to be assured and evaluated in manufacturing process. Finite element method (FEM) is performed in order to evaluate the minimum allowable flaw sizes that are possibly generated in the composite-sintered bushings. Additionally, the composite-sintered bushings were undergone ultrasonic C-scan tests to find out the size of inherent flaws through artificially simulated UT signal analysis.

Fatigue Characteristics and its Nondestructive Evaluation of Fire-resistance Steel for Construction with Low Yield Ratio and High Strength (저항복비·고강도 구조용 내화강의 피로특성 및 비파괴평가)

  • Kim, H.S.;Nam, K.W.;Kang, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.4
    • /
    • pp.212-219
    • /
    • 2001
  • The fatigue test was carried out to evaluate the fatigue characteristics of fire resistance steel for frame structure and heat affected zone (HAZ) by the one side Gas Metal Arc Welding (GMAW). In this paper, the fatigue crack growth behavior was investigated with the compact tension specimen of base metal and the HAZ according to chemical composition and rolling end temperature, respectively. And the acoustic emission signals obtained from the fatigue test were analyzed by the time-frequency analysis method as a nondestructive evaluation. Main results obtained are summarized as follows; The hardness was appeared softening phenomenon that weld metal and HAZ are lower than that of base metal. Fatigue life of welded specimen was longer than that of base metal. m was 3~4.5 in base metal and 3.8~5.8 in HAZ. The main frequency range of acoustic emission signal analyzed from time-frequency method is different with the range by noise and crack. Also, it could be classified that it was also generated by fracture mechanics of dimple, inclusion etc.

  • PDF

Under the fading channel environment, performance evaluation of AF CR loop Due to the quantization effect (페이딩 채널 환경하에서의 양자화 특성에 의한 AF CR loop의 성능평가)

  • 송재철;이경하;김선형;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.737-746
    • /
    • 1996
  • In this paper, we present simulation result of quantization effects about a new Angular From Carrier Recovery Loop(AF CR loop) for PSK modulation technique. AF CR loop includes detected angle symbol and Multi Level hardimiter. In general, detected angle is used in dtermining symbol. Because detected angle is used to make an error signal of phase detector output, hardware implementation of AF CR loop is simpler than that of other loops. Before hardware implementation of AF CR loop, the result due to quantization effect should be investigated. In order to confirm quntization effect of AF CR loop, we evaluate performance of this loop by Monte-Carlosimulation method. Under both in the AWGN and Jake's fading noise channel environments, we confirmed the characteristics of AF CR loop in terms of RMS jitter due to quntization effect. Differential APSK modulation schemeis used in this paper. Especially, Jake's fading channel is used as a channel model and also AGC(Automatic Gain Control) is used in the overall process of performance evaluation. We obtained the resonable result of quantization effect about AF CR loop. With the result of performanceevaluation based on quantization effects, we can expect to operate AF CRloop under the fading channel environments reasonably well.

  • PDF

Practical Development and Evaluation of Advanced Alarm System for Nuclear Power Plant (원자력 플랜트의 개량형 경보시스템 개발 및 평가사례)

  • Jang Gui-Suk
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.4
    • /
    • pp.229-240
    • /
    • 2006
  • The advanced Alarm System (AS) employs modem digital technology to implement the alarm functions of the NPP(Nuclear Power Plant). The use of modem digital technology can provide advanced alarm processing in which new algorithms such as a signal validation, advanced alarm processing logic and other features are applied to improve the control room man-machine interfaces. This paper will describe the design process of the AS of NPP, improving the system reliability and availability using the reliability prediction tool, design strategies regarding the human performance topics associated with a computer-based AS and the results of the performance analysis using a prototype of the AS.