• Title/Summary/Keyword: Signal Evaluation

Search Result 1,921, Processing Time 0.03 seconds

Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.

Wiener filtering-based ambient noise reduction technique for improved acoustic target detection of directional frequency analysis and recording sonobuoy (Directional frequency analysis and recording 소노부이의 표적 탐지 성능 향상을 위한 위너필터링 기반 주변 소음 제거 기법)

  • Hong, Jungpyo;Bae, Inyeong;Seok, Jongwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.192-198
    • /
    • 2022
  • As an effective weapon system for anti-submarine warfare, DIrectional Frequency Analysis and Recording (DIFAR) sonobuoy detects underwater targets via beamforming with three channels composed of an omni-direcitonal and two directional channels. However, ambient noise degrades the detection performance of DIFAR sonobouy in specific direction (0°, 90°, 180°, 270°). Thus, an ambient noise redcution technique is proposed for performance improvement of acoustic target detection of DIFAR sonobuoy. The proposed method is based on OTA (Order Truncate Average), which is widely used in sonar signal processing area, for ambient noise estimation and Wiener filtering, which is widely used in speech signal processing area, for noise reduction. For evaluation, we compare mean square errors of target bearing estmation results of conventional and proposed methods and we confirmed that the proposed method is effective under 0 dB signal-to-noise ratio.

Evaluation by Contrast-Enhanced MR Imaging of the Lateral Border Zone in Reperfused Myocardial Infarction in a Cat Model

  • Ae Kyung Jeong;Sang Il Choi;Dong Hun Kim;Sung Bin Park;Seoung Soo Lee;Seong Hoon Choi;Tae-Hwan Lim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • Objective: To identify and evaluate the lateral border zone by comparing the size and distribution of the abnormal signal area demonstrated by MR imaging with the infarct area revealed by pathological examination in a reperfused myocardial infarction cat model. Materials and Methods: In eight cats, the left anterior descending coronary artery was occluded for 90 minutes, and this was followed by 90 minutes of reperfusion. ECG-triggered breath-hold turbo spin-echo T2-weighted MR images were initially obtained along the short axis of the heart before the administration of contrast media. After the injection of Gadomer-17 and Gadophrin-2, contrast-enhanced T1-weighted MR images were obtained for three hours. The size of the abnormal signal area seen on each image was compared with that of the infarct area after TTC staining. To assess ultrastructural changes in the myocardium at the infarct area, lateral border zone and normal myocardium, electron microscopic examination was performed. Results: The high signal area seen on T2-weighted images and the enhanced area seen on Gadomer-17-enhanced T1WI were larger than the enhanced area on Gadophrin-2-enhanced T1WI and the infarct area revealed by TTC staining; the difference was expressed as a percentage of the size of the total left ventricle mass (T2= 39.2 %; Gadomer-17 =37.25 % vs Gadophrin-2 = 29.6 %; TTC staining = 28.2 %; p < 0.05). The ultrastructural changes seen at the lateral border zone were compatible with reversible myocardial damage. Conclusion: In a reperfused myocardial infarction cat model, the presence and size of the lateral border zone can be determined by means of Gadomer-17- and Gadophrin-2-enhanced MR imaging.

  • PDF

Design and Development of TRM for NEXTSat-2 X-band Synthetic Aperture Radar (차세대소형위성2호 X대역 합성 개구 레이더용 송·수신 모듈의 설계 및 개발)

  • Jeeheung Kim;Dong Guk Kim;Ilyoung Jang
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.2
    • /
    • pp.193-200
    • /
    • 2024
  • This paper describes the design and development of a transmit receiver module(TRM) for mounting on X-band SAR of the NEXTSat-2. The TRM generates the chirp signal with required bandwidth through the DDS in X-band and performs frequency conversion, combination for the signal to transmit and be received and frequency synthesis. Tx path of the TRM produces signals of total 28 bandwidths up to 96.8 MHz and has output signal level of more than + 9.37 dBm. Rx path of the TRM has minimum noise figure of 15.7 dB. The measurement results show that required requirements are satisfied. The TRM is installed on the NEXTSat-2 flight model(FM), launched by KSLV-II(Nuri) on May 23, 2023 and currently operational.

Symbol Power Allocation and Channel Estimation Method for LR-WPAN System (LR-WPAN 시스템에서 심볼 전력 할당과 2개의 직교 코드를 사용한 채널 추정 기법)

  • Lee, Kyung-Tak;Lee, Sung-Jun;Sohn, Sung-Hwan;Kim, Jae-Moung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.1-10
    • /
    • 2007
  • In this paper, we proposed channel estimation scheme for LR-UWB system which has low data rate for WPAN in IEEE 802.15.4a. At the transmitter, we proposed dynamic power level allocation depends on channel condition in specific period when we modulate signal. We use two orthogonal code to estimate channel at once. It can estimate channel more accurately by using two code which shows good correlation characteristic then it can estimate more accurately by spreading gain. Using estimated channel condition, we synchronize symbol timing of transmitted signal. Then determined power allocation scheme and channel information is transmitted to transmiter side. Finally, using these information, transmiter side change the power level of repeated pulse to adopt to channel condition. Simulation is performed under S-V channel for LR-WPAN in IEEE 802.15.4a and we compare the performance with a different type of receiver type. We use coherent and non-coherent method at the receiver. Simulation result shows us at the NLOS channal performance evaluation is greater than that of LOS channel and the result is independent of receiver type. In the NLOS channel, as the signal delay spreading is big, performance evaluation is also increased.

Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence (두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.167-172
    • /
    • 1999
  • Purpose : To evaluate the detection rate of hyperacute intracerebral hemorrhage in echo planar imaging (EPI) and other MR sequences. materials and Methods : Intracerebral hemorrhage was experimentally induced in ten rats. EPI, fast spin-echo (FSE) T2 weighted images, fluid attenuated inversion recovery (FLAIR), spin-echo (SE) T1 weighted images and gradient echo (GE) T1 weight ed images of rat's brains were obtained 2 hours after onset of intracerebral hemorrhage. EPI and FSE T2 images were additionally obtained 30 min and 1 hour after onset of hemorrhage in 3 and 6 rat, repeatedly, For objective visual assessment, discrimination between the lesion and normal brain parenchyma was evaluated on various MR sequences by three radiologists. For quantitative assessment, contrast-to-noise ratio (CNR) was calculated fro hemorrhage-normal brain parenchyma. Statistical analysis was performed usning the Wilcoxon-Ranks test. Results : EPI, FLAIR, and FSE T2 images showed high signal intensity lesions. The lesion discrimination was easier on EPI than on other sequences, and also EPI showed higher signal intensity for the subjective visual assessment. In quantitative evaluation, CNR of the hemorrhagic lesion versus normal brain parenchyma were higher on EPI and FLAIR images (p<0.01). There was no difference in CNR between EPI and FLAIR (p>0.10). On MR images obtained 30 minutes and 1 hour after the onset of intracerebral hemorrhage, the lesion detection was feasible on both EPI and FSE T2 images showing high signal intensity. Conclusion : EPI showed higher detection rate as compared with other MR sequences and could be useful in early detection and evaluation of intracerebral hemorrhage.

  • PDF

Touch-Pen Noise Reduction Using B-Spline Function (B-Spline 곡선을 이용한 터치펜 잡음제거)

  • Lee, Sang-Bum
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.121-126
    • /
    • 2017
  • Recently, a lot of people use touch-pen devices such as smart phones and tab computers. To generate the picture and text, a user can give input or control the touch-pen device through simple or multi-touch gestures by touching the screen with a special stylus pen and/or one or more fingers. The accuracy and response time from the moment of contact with the touch board is very important to the touch device. Therefore, research is needed to find a way of removing the noise included in the touch signal quickly and efficiently. In this paper, we propose a method for removing a noise mixed in with a touch point coordinate which has been caused by a input pen on the touch screen. For effective filtering, the fast sampling of the coordinate corresponding to the noise from the input signal is required primarily. Secondly the total compensation of the touch coordinates using the characteristics of the B-Spline curve is applied to correct coordinates of the points. This method can ensure a real-time response than other algorithms. The applied performance evaluation method is comparing error pixels with evaluation values by dividing 10 intervals on the touch pad diagonally. Usually the average error is 7.1 pixels but our proposed method shows an average 4.1 errors. Therefore, our proposed touch pen method can express the input signal on the coordinates more correctly.

BER Performance Evaluation of Boss Map According to Delay Time in CDSK Modulation Scheme and Chaos Transceiver (CDSK 변조 방식과 카오스 송수신기의 지연시간에 따른 Boss Map의 BER 성능 평가)

  • Lee, Jun-Hyun;Keum, Hong-Sik;Lee, Dong-Hyung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.7
    • /
    • pp.365-371
    • /
    • 2014
  • Chaos communication system is possible to improve the system security by using chaos signal. Further, it is possible to reduce the possibility of eavesdropping, and have strong characteristics from interference signal and jamming signal. However, BER(Bit Error Rate) performance of chaos system is worse than digital communication system. By this reason, researches in order to improve the BER performance of chaos communication system are being actively studied. In previous studies, we proposed a novel chaos map for BER performance improvement, and called it 'Boss map'. Also, we proposed a novel chaos transceiver for BER performance improvement. However, BER performance is evaluated differently according to delay time in transceiver. Therefore, in order to use Boss map effectively, we should find the optimal delay time in proposed chaos transceiver. In this paper, when Boss map is used, we evaluate BER performance of CDSK(Correlation Delay Shift Keying) system and novel chaos transceiver according to delay time. After evaluation of BER performance according to delay time, we find a delay time that is possible to have best BER performance in CDSK system and novel chaos transceiver.

Performance Evaluation of Nonhomogeneity Detector According to Various Normalization Methods in Nonhomogeneous Clutter Environment (불균일한 클러터 환경 안에서 Nonhomogeneity Detector의 다양한 정규화 방법에 따른 성능 평가)

  • Ryu, Jang-Hee;Jeong, Ji-Chai
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.72-79
    • /
    • 2009
  • This paper describes the performance evaluation of NHD(nonhomogeneity detector) for STAP(space-time adaptive processing) airborne radar according to various normalization methods in the nonhomogeneous clutter environment. In practice, the clutter can be characterized as random variation signals, because it sometimes includes signals with very large magnitude like impulsive signal due to the system environment. The received interference signals are composed of homogeneous and nonhomogeneous data. In this situation, NHB is needed to maintain the STAP performance. The normalization using the NHD result is an effective method for removing the nonhomogeneous data. The optimum normalization can be performed by a representative value considered with a characteristic of the given data, so we propose the K-means clustering algorithm. The characteristic of random variation data due to nonhomogeneous clutters can be considered by the number of clusters, and then the representative value for selecting the homogeneous data is determined in the clustering result. In order to reflect a characteristic of the nonstationary interference data, we also investigate the algorithm for a calculation of the proper number of clusters. Through our simulations, we verified that the K-means clustering algorithm has very superior normalization and target detection performances compared with the previous introduced normalization methods.

  • PDF

Performance Evaluation of Underwater Acoustic Communication in Frequency Selective Shallow Water (주파수 선택적인 천해해역에서 수중음향통신 성능해석)

  • Park, Kyu-Chil;Park, Jihyun;Lee, Seung Wook;Jung, Jin Woo;Shin, Jungchae;Yoon, Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.95-103
    • /
    • 2013
  • An underwater acoustic (UWA) communication in shallow water is strongly affected by the water surface and the seabed acoustical properties. Every reflected signal to receiver experiences a time-variant scattering in sea surface roughness and a grazing-angle-dependent reflection loss in bottom. Consequently, the performance of UWA communication systems is degraded, and high-speed digital communication is disrupted. If there is a dominant signal path such as a direct path, the received signal is modeled statistically as Rice fading but if not, it is modeled as Rayleigh fading. However, it has been known to be very difficult to reproduce the statistical estimation by real experimental evaluation in the sea. To give an insight for this scattering and grazing-angle-dependent bottom reflection loss effect in UWA communication, authors conduct experiments to quantify these effects. The image is transmitted using binary frequency shift keying (BFSK) modulation. The quality of the received image is shown to be affected by water surface scattering and grazing-angle-dependent bottom reflection loss. The analysis is based on the transmitter to receiver range and the receiver depth dependent image quality and bit error rate (BER). The results show that the received image quality is highly dependent on the transmitter-receiver range and receiver depth which characterizes the channel coherence bandwidth.