• Title/Summary/Keyword: Signal Evaluation

Search Result 1,910, Processing Time 0.052 seconds

Effect of Unripe Apple Peel Water Extracts on Tyrosinase Activity and Melanin Production in B16F10 Melanoma Cells (B16F10 melanoma 세포에서 미성숙 사과 과피 열수추출물의 tyrosinase 활성과 melanin 생 성에 미치는 영향)

  • Jang, Young-Ah;Lee, Jin-Tae
    • Journal of Life Science
    • /
    • v.28 no.8
    • /
    • pp.900-907
    • /
    • 2018
  • This study was carried out to evaluate the possibility of unripe apple peel water extracts as cosmetic materials and to evaluate the biological activities of the antioxidant and whitening effects of the samples. The antioxidative properties of the samples were confirmed by 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity and 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) cation radical scavenging ability. To evaluate the whitening effect of the samples, several analytical techniques were used, including toxicity evaluations of the samples by MTT assays. Measurements of the inhibition rates of cellular tyrosinase, melanin synthesis rates, and expression rates of whitening-related proteins and genes were confirmed using melanoma (B16F10 cell). At equivalent unripe apple peel water concentrations ($1,000{\mu}g/ml$), the DPPH radical scavenging and the ABTS cation radical scavenging activities were 77.3% and 93.1%, respectively. The whitening activity evaluation showed that tyrosinase activity and melanin synthesis were inhibited by 19.8% and 17.3%, respectively, at unripe apple peel water extract concentrations of $50{\mu}g/ml$. In B16F10 cells induced by ${\alpha}$-MSH, the expression of tyrosinase, TRP-1, and TRP-2 decreased. Also, the activity of the transcription factor MITF was inhibited. In real-time PCR experiments, the expression of related genes at the upstream signal level was also found to be progressively lowered as the concentration of unripe apple peel water extracts increased. From these results, it was confirmed that the unripe apple peel water extracts showed excellent whitening efficacy and could be used as safe, natural, raw cosmetic material in the future.

Dynamic Analyses on Embedded Piles Based on Wave Equation (파동방정식에 근거한 매입말뚝의 동적 분석)

  • Seo, Mi-Jeong;Park, Jong-Bae;Park, Yong-Boo;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.11
    • /
    • pp.5-13
    • /
    • 2015
  • For the bearing capacity evaluation, dynamic pile tests instead of static pile tests have been commonly used in embedded piles, which are known to have low noise and low vibration construction method. The objective of this study is to analyze the bearing capacity and penetration behaviors of embedded piles, which are constructed in different ground conditions, by using force and velocity signals obtained in the final blows during construction of embedded piles. For the dynamic pile analyses, the CAse Pile Wave Analysis Program (CAPWAP) and Wave Equation Analysis of Piles (WEAP) have been commonly used. In this study, the CAPWAP and WEAP are used for the analyses of the dynamic pile tests, which are conducted on embedded piles. The input values, output values, and force-velocity graphs of CAPWAP determined by analyzing the measured force-velocity signals are investigated. In addition, similar force-velocity singals are obtained from the WEAP by analyzing the input values of the WEAP. Considering the subsurface investigation results around the pile tips, if the N-value increases exponentially along the depth, toe quake value should be small, and therefore large bearing capacity is identified. On the contrary, if the N-value increases linearly, the bearing capacity is small because of large toe quake value. Furthermore, the stiffness of hammer cushion and pile cushion, which is difficult to find correct values, is recommended lower than 500 kN/mm. This study demonstrates that the results of WEAP may be similar to those of CAPWAP and the WEAP can be used to estimate the bearing capacity of embedded piles.

The Evaluation of Lower Extremity Muscles in Combat shoes Custom Foot Orthotics (전투화 맟춤형 발보장구 착용 시 하지 근육 활동의 평가)

  • Suh, Sung-Hyeok;Kim, Ro-Bin;Cho, Young-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to examine the effects of customized foot orthotics on lower extremity muscle activity and fatigue during march in combat boots. Four volunteers with normal foot and five volunteers with excessive pronation foot among soldiers on service were fitted with foot orthotics. The electromyography signal from activity of low extremity muscles were collected with surface electromyography device during walking on the treadmill. The walk on the treadmill was performed with a speed of 4.5 km/h. The experiment design for reseach wes composed two experimentation. The first experiment was to examine the muscle activity of lower extremity between normal foot and excessive pronator foot during march. The second experiment was to examine the muscle activity of lower extremity between wearing orthotics and no wearing orthotics. These data were analyzed by the averaged integral EMG and the mean power frequency. The analyzed results were compared by independent T-test method and paired T-test method of SPSS(windows version 12.0). The result of the study were the muscle activity on pronator foot tend to increase during march but a statistically significant increase in muscle fatigue of vastus lateralis and fibularis longus. A statistically significant decrease in muscle activity of anterior tibialis and fibularis longus and fatigue occurred using the customized foot orthotics in volunteers with excessive pronation foot compared to volunteers with normal foot. Clinically, the application of orthotics for the soldiers with excessive pronation foot appears to delay muscle fatigue and prevent from variable foot injuries. This may contribute to enhancing fighting efficiency.

A Study on 3D RTLS at Port Container Yards Using the Extended Kalman Filter

  • Kim, Joeng-Hoon;Lee, Hyun-Woo;Kwon, Soon-Ryang
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.7 no.4
    • /
    • pp.228-235
    • /
    • 2007
  • The main purpose of this paper is to manage the container property effectively at the container yard by applying the RTLS technology to the field of port logistics. Yet, many kinds of noises happen to be inputted with the distance value(between the reader and the tag) which is to be inputted into the location identification algorithm, which makes the distance value jumped due to the system noise of the ultrasonic sensor module and the measurement noise. The Kalman Filter is widely used to prevent this jump occurrence; the noises are eliminated by using the EKF(Extended Kalman Filter) while considering that the distance information of the ultrasonic sensor is non-linear. Also, the 3D RTLS system at the port container yard suggested in this research is designed not to be interrupted for its ultrasonic transmission by positioning the antenna at the front of each sector of the container where the active tags are installed. We positioned the readers, which function as antennas for location identification, to four places randomly in the absolute coordinate and let the positions of the active tags identified by using the distance data delivered from the active tags. For the location identification algorithm used in this paper, the triangulation measurement that is most used in general is applied and newly reorganized to calculate the position of the container. In the first experiment, we dealt with the error resulting in the angle and the distance of the ultrasonic sensor module, which is the most important in the hardware performance; in the second, we evaluated the performance of the location identification algorithm, which is the most important in the software performance, and tested the noise cancellation effects for the EKF. According to the experiment result, the ultrasonic sensor showed an average of 3 to 5cm error up to $45^{\circ}$ in case of $60^{\circ}$ or more, non-reliable linear distances were obtained. In addition, the evaluation of the algorithm performance showed an average of $4^{\circ}{\sim}5^{\circ}$ error due to the error of the linear distance-this error is negligible for most container location identifications. Lastly, the experiment results of noise cancellation and jump preservation by using the EKF showed that noises were removed in the distance information which was entered from the input of the ultrasonic sensor and as a result, only signal was extracted; thus, jumps were able to be removed and the exact distance information between the ultrasonic sensors could be obtained.

T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques (3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교)

  • Jeong, Jee-Young;Yoo, So-Young;Jang, Kyung-Mi;Eo, Hong;Lee, Jung-Hee;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the usefulness of fast inversion recovery (FIR) and magnetization-prepared three dimensional gradient echo sequence (3D GRE) T1-weighted sequences for neonatal brain imaging compared with spin echo (SE) sequence in a 3T MR unit. Materials and Methods: T1-weighted axial SE, FIR and 3D GRE sequences were evaluated from 3T brain MR imaging in 20 neonates. The signal-to-noise ratio (SNR) of different tissues was measured and contrast-to-noise ratios (CNR) were determined and compared in each of the sequences. Visual analysis was carried out by grading gray-white matter differentiation, myelination, and artifacts. The Wilcoxon signed ranked test was used for evaluation of the statistical significance of CNR differences between the sequences. Results: Among the three sequences, the 3D GRE had the best SNRs. CNRs obtained with FIR and 3D GRE were statistically superior to those obtained with SE; these CNRs were better on the 3D GRE compared to the FIR. Gray to white matter differentiation and myelination were better delineated on the FIR and 3D GRE than the SE. However, motion artifacts were more commonly observed on the 3D GRE and flow-related artifacts of vessels were frequently seen on the FIR. Conclusion: FIR and 3D GRE are valuable alternative T1-weighted sequences to conventional SE imaging of the neonatal brain at 3T providing superior image quality.

  • PDF

The evaluation of useful on the additional PET/CT Liver scan (PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가)

  • Park, Se Youn;Lee, Hwa Jin;Lee, Mu Seok;Kim, Jung Uk;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.46-48
    • /
    • 2016
  • Purpose The liver one of the most common site for distant metastasis for a variety of tumor, especially of gastrointestinal origin. the purpose of this study was to analyze image quality between standard scan and additional liver scan. Materials and Methods From September 2015 to February 2016. 152 patients were examined undergo gastrointestinal cancer. 32 patients confirmed liver metastasis analyzed same liver ROI level and check the SNR, SUV and T/N ratio Results The $SNR_{mean}$ of standard was $17.7{\pm}10.3$; addition was $22.3{\pm}9.7$ (p<0.05). In $SUV_{max}$ of standard was $6.7{\pm}2.8$; addition was $7.6{\pm}3.2$ (P<0.05). and the T/N ratio of standard was $2.1{\pm}0.6$; addition was $2.5{\pm}0.8$ (P<0.05). Conclusion The $SNR_{mean}$, $SUV_{max}$ and T/N ratio were higher than those on the first scan (P<0.05). The SNRmean showed the highest change rate among the parameters. A additional liver scan is more favorable for the detection of gastrointestinal cancer patients.

  • PDF

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

Intraoperative Neurophysiological Monitoring : A Review of Techniques Used for Brain Tumor Surgery in Children

  • Kim, Keewon;Cho, Charles;Bang, Moon-suk;Shin, Hyung-ik;Phi, Ji-Hoon;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.363-375
    • /
    • 2018
  • Intraoperative monitoring (IOM) utilizes electrophysiological techniques as a surrogate test and evaluation of nervous function while a patient is under general anesthesia. They are increasingly used for procedures, both surgical and endovascular, to avoid injury during an operation, examine neurological tissue to guide the surgery, or to test electrophysiological function to allow for more complete resection or corrections. The application of IOM during pediatric brain tumor resections encompasses a unique set of technical issues. First, obtaining stable and reliable responses in children of different ages requires detailed understanding of normal age-adjusted brain-spine development. Neurophysiology, anatomy, and anthropometry of children are different from those of adults. Second, monitoring of the brain may include risk to eloquent functions and cranial nerve functions that are difficult with the usual neurophysiological techniques. Third, interpretation of signal change requires unique sets of normative values specific for children of that age. Fourth, tumor resection involves multiple considerations including defining tumor type, size, location, pathophysiology that might require maximal removal of lesion or minimal intervention. IOM techniques can be divided into monitoring and mapping. Mapping involves identification of specific neural structures to avoid or minimize injury. Monitoring is continuous acquisition of neural signals to determine the integrity of the full longitudinal path of the neural system of interest. Motor evoked potentials and somatosensory evoked potentials are representative methodologies for monitoring. Free-running electromyography is also used to monitor irritation or damage to the motor nerves in the lower motor neuron level : cranial nerves, roots, and peripheral nerves. For the surgery of infratentorial tumors, in addition to free-running electromyography of the bulbar muscles, brainstem auditory evoked potentials or corticobulbar motor evoked potentials could be combined to prevent injury of the cranial nerves or nucleus. IOM for cerebral tumors can adopt direct cortical stimulation or direct subcortical stimulation to map the corticospinal pathways in the vicinity of lesion. IOM is a diagnostic as well as interventional tool for neurosurgery. To prove clinical evidence of it is not simple. Randomized controlled prospective studies may not be possible due to ethical reasons. However, prospective longitudinal studies confirming prognostic value of IOM are available. Furthermore, oncological outcome has also been shown to be superior in some brain tumors, with IOM. New methodologies of IOM are being developed and clinically applied. This review establishes a composite view of techniques used today, noting differences between adult and pediatric monitoring.

Splitting between Region of Chromatic and Achromatic by Brightness and Chroma (명암과 채도에 의한 색상영역과 비색상영역의 분할)

  • Kwak, Nae-Joung;Hwang, Jae-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.107-114
    • /
    • 2010
  • Color is a sense signal for human to perceive being through light, and the color is divided into chromatic color and achromatic color. Chromatic color has hue, intensity, and saturation, but achromatic color has only intensity among the properties of chromatic color and doesn't have hue and saturation. Therefore it is important to split colors of image into area for human to perceive colors and not to perceive ones based on vision of human being. In this paper, we find a function to split colors of image into chromatic region of chromatic color region and achromatic region of achromatic color region. First, the input image of RGB color space is converted into the image of HSI color space in consideration of human vision and get a binary image from the converted image. After then, a function to split colors into ROC(ROC: Region of chromatic.) and ROA(ROA:Region of achromatic) is yield. It is difficult to split color of a general image into ROC and ROA. Therefore, to get the chromatic area and achromatic area, we make gradient images to have all range of intensity and range of saturation and to have a little range of hue and yield the function. The evaluation is tested using subjective-quality by 50 non-experts for result images of test images and general images. The results of the proposed method get better 27.5~32.96% than these of the conventional method

Pre-operative Evaluation of Consistency in Intra-axial Brain Tumor with Diffusion-weighted Images (DWI) and Conventional MR Images (확산강조영상과 고식적 자기공명영상을 이용한 수술 전 축내 뇌종양의 경도 평가)

  • Oh, Moon-Sik;Ahn, Kook-Jin;Choi, Hyun-Seok;Jung, So-Lyung;Lee, Yoon-Joo;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.102-109
    • /
    • 2011
  • Purpose : To retrospectively evaluate the usefulness of diffusion-weighted images, ADC maps and conventional MR images for determination of brain tumor consistency. Materials and Methods : Twenty-three patients with brain tumor underwent MR examinations with T1, T2 and diffusion-weighted images. Regions of interest (ROIs) were drawn in the tumors, and the measured signal intensities (SI) were normalized with the contralateral side. We evaluated the correlation between SI ratios from various images and tumor consistency assessed at surgery. In three patients with both cystic and solid components, each component was evaluated independently. Qualitatively observed SIs were also correlated with tumor consistency. Results : Statistical analysis revealed significant correlation between tumor consistency and ADC ratio (r = -0.586, p = 0.002), SI ratios on T2-weighted images (r = -0.497, p = 0.010), and observed SIs on T2-weighted images (r = -0.461, p = 0.018). The relative ratio of ADC value correlated with tumor consistency most strongly. Conclusion : The measured ratio of ADC, SI ratio and observed SI grade on T2-weighted images can provide valuable information about the consistency of brain tumor.