• 제목/요약/키워드: Signal Detector

검색결과 997건 처리시간 0.029초

전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구 (A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography)

  • 임윤빈;문홍만;조현택;백영종;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1741-1744
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

  • PDF

Search for Dark Photon in e+e- → A'A' Using Future Collider Experiments

  • Kihong Park;Kyungho Kim;Alexei Sytov;Kihyeon Cho
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권4호
    • /
    • pp.259-266
    • /
    • 2023
  • The Standard Model (SM) does not provide an information for 26% of dark matter of the universe. In the dark sector, dark matter is supposed to be linked with the hypothetical particles called dark photons that have similar role to photons in electromagnetic interaction in the SM. Besides astronomical observation, there are studies to find dark matter candidates using accelerators. In this paper, we searched for dark photons using future electron-positron colliders, including Circular Electron Positron Collider (CEPC)/CEPC, Future Circular Collider (FCC-ee)/Innovative Detector for Electron-positron Accelerator (IDEA), and International Linear Collider (ILC)/International Large Detector (ILD). Using the parameterized response of the detector simulation of Delphes, we studied the sensitivity of a double dark photon mode at each accelerator/detector. The signal mode is double dark photon decay channel, e+e- → A'A', where A' (dark photon with spin 1) decaying into a muon pair. We used MadGraph5 to generate Monte Carlo (MC) events by means of a Simplified Model. We found the dark photon mass at which the cross-sections were the highest for each accelerator to obtain the maximum number of events. In this paper we show the expected number of dark photon signal events and the detector efficiency of each accelerator. The results of this study can facilitate in the dark photon search by future electron-positron accelerators.

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

SEM용 전자검출기의 제작 및 성능평가 (Manufacture and Performance Estimation of Electron Detector for SEM)

  • 김지원;전종업;부경석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1282-1287
    • /
    • 2007
  • The nature of the signal collected by an SEM(Scanning Electron Microscope) in order to form images are all dependent on the detector used to collect them, and the quality of an acquired images is strongly influenced by detector performance. Therefore, the development of detector with high performance is very important for improving on the resolution of SEM. This paper presents the manufacture of secondary electron detector and the optimal position of electron detector through numerical analysis in SEM.

  • PDF

Analysis of the Generalized Order Statistics Constant False Alarm Rate Detector

  • Kim, Chang-Joo;Lee, Hwang-Soo
    • ETRI Journal
    • /
    • 제16권1호
    • /
    • pp.17-34
    • /
    • 1994
  • In this paper, we present an architecture of the constant false alarm rate (CFAR) detector called the generalized order statistics (GOS) CFAR detector, which covers various order statistics (OS) and cell-averaging (CA) CFAR detectors as special cases. For the proposed GOS CFAR detector, we obtain unified formulas for the false alarm and detection probabilities. By properly choosing coefficients of the GOS CFAR detector, one can utilize any combination of ordered samples to estimate the background noise level. Thus, if we use a reference window of size N, we can realize $(2^N-1)$ kinds of CFAR processors and obtain their performances from the unified formulas. Some examples are the CA, the OS, the censored mean level, and the trimmed mean CFAR detectors. As an application of the GOS CFAR detector to multiple target detection, we propose an algorithm called the adaptive mean level detector, which censors adaptively the interfering target returns in a reference window.

  • PDF

DS-CDMA 시스템을 위한 결정 귀환 검출기와 결합된 적응 최소평균제곱오류 다중사용자 검출기법 (Adaptive MMSE multiuser detector combined with decision-feedback detector for DS-CDMA system)

  • 이혜정;이재흥
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.69-72
    • /
    • 2002
  • In this paper, adaptive minimum mean-squared error (MMSE) multiuser detector combined with decision-feedback detector (DFD) is considered fur near-far resistant DS-CDMA system. To provide a reliable input to the adaptive MMSE detector, multiple-access interference (MAI) is regenerated using bit estimates from DFD and subtracted from the received signal. In the adaptive MMSE detector, the effect of the imperfect cancellation is compensated by a least mean square (LMS) algorithm. Through the numerical results, it is shown that, in a near-far situation, the proposed scheme provides superior performance to the matched filter (MF) receiver, adaptive MMSE detector, and DFD in terms of the bit error rate (BER).

  • PDF

DS/CDMA 시스템의 개선된 MMSE 다중사용자 검파기 성능분석 (Performance Analysis of Advanced MMSE Multi-User Detector for DS/CDMA systems)

  • 감두열
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1540-1547
    • /
    • 2000
  • In this paper, the performance of the MMSE multiuser detector is compared with the conventional detector with respect to the signal-to-noise ratio, the number of users and the Nakagami parameter under AWGN as well as Nakagami fading channel. The results show that the MMSE multiuser detector is superior to the conventional detector with respect to cancelling the multiple access interference. However, its drawback is the hardware's complexity. To solve this drawback, the advanced MMSE multiuser detector is presented, and its performance is analyzed. The number of taps in the advanced MMSE multiuser are independent of the processing gain. Thus, the system engineer can choose the appropriate number of taps in the detector to achieve a optimal trade-off between the hardware complexity and the performance of system.

  • PDF

디지털 고밀도 자기기록 장치의 재생신호 처리에 관한 연구 (Playback Signal Processing in a Digital High Density Magnetic Recording System)

  • 이상록;박시우;박선기;박진우
    • 전자공학회논문지B
    • /
    • 제30B권12호
    • /
    • pp.31-39
    • /
    • 1993
  • In the playback signal processing of a digital magnetic recording system, the major signal processing processes consist of pulse equalization. pulse detection, clock recovery, and data recovery. Equalizer which compensates interference occurrde between pulses recorded in high density on a magnetic media is realized by pulse slimming method, and pulse detection by a integrating detector. Clock recovery from the detector output was accomplished by using PLL. and data recovery to reduce noise effects was carried out by utilizing the three sampling clocks recovered in clock recovery process. In this paper these processes are implemented in hardware and its performance is evaluated by experimenting with a commercial DAT. It was found that the playback signal processor proposed is suitable to the practical high density magnetic recording system.

  • PDF

신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현 (Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis)

  • 김성철;조병남;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.331-333
    • /
    • 2004
  • In this study, we implement the multiple frequency bioelectrical impedance analysis system for body composition analysis. Overall system consists of : 1) conductivity electrodes to contact with hands and foots, 2) multiple frequency alternating current signal generator for generating 5, 50, 250kHz frequency and 800uA contained alternating current signal, 3) voltage signal detector, 4) phase signal detector, 5) key-pad to input individual information, 6) micro controller for data processing, 7) LCD for processed data to display, 8) system power, We explain the architecture of the system and required theory to implement the system. Finally, experimental results are illustrated to show the performance of the system.

  • PDF

노이즈에 둔감한 레이저 진동계측기용 실시간 신호처리 장치에 관한 연구 (A Study on the Robust Real-Time Signal Processor of a Laser Doppler Vibrometer for Noises)

  • 박승규;백성훈;김철중
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.61-67
    • /
    • 1999
  • A laser Doppler vibrometer based on the laser heterodyne interferometry is employed to measure the vibration velocity of vibrating objects. In this paper, we propose a real time analog signal processor of a laser Doppler vibrometer to reduce the degradation of Doppler signals mainly caused by environmental noises. In the proposed real time signal processor of an laser Doppler vibrometer, a pre-processor and a logical motion direction detector are designed to reduce the detection errors of the object motion direction. Also, a noise detection and rejection circuit is designed to reject the unfiltered noises.

  • PDF