• Title/Summary/Keyword: Signal Correlation

Search Result 1,571, Processing Time 0.026 seconds

Expression of Hypoxia-inducible Factor-1 $\alpha$ in Esophageal Squamous Cell Carcinoma: Relationship to Prognosis and Tumor Biomarkers (식도 편평세포암에시 Hypoxia-inducible Factor-1 $\alpha$의 발현: 예후와 종양표지자와의 상관성)

  • 양일종;김종인;이해영;천봉권;조성래
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.691-701
    • /
    • 2004
  • Background: Tissue hypoxia is a characteristic of many human malignant neoplasms, and hypoxia inducible factor-1 (HIF-1) plays a pivotal role in essential adaptive response to hypoxia, and activates a signal pathway for the expression of the hypoxia-regulated genes, resulting in increased oxygen delivery or facilitating metabolic adaptation to hypoxia. Increased level of HIF-1 a has been reported in many human malignancies, but in esophageal squamous cell carcinoma, the influence of HIF-1 a on tumor biology, including neovascularization, is not still defined. Material and Method: The influence of HIF-1 a expression on angiogenic factors, correlation between the tumor proliferation and HIF-1 a expression, interaction of HIF-1 a expression and p53, and correlation between HIF-1 a expression and clinicopathological prognostic parameters were investigated, using immunohistochemical stains for HIF-1 a, VEGF, CD34, p53, and Ki-67 on 77 cases of resected esophageal squamous cell carcinoma. Result: HIF-1 a expression in cancer cells was found in 33 of 77 esophageal squamous cell carcinoma cases. The 33 cases (42.9%) showed positive stain for HIF-1 a. High HIF-1 a expression was significantly associated with several pathological parameters, such as histologic grade (p=0.032), pathological TMN stage (p=0.002), the depth of tumor invasion (p=0.022), regional lymph node metastasis (p=0.002), distant metastasis (p=0.049), and lymphatic invasion (p=0.004). High HIF-1 a expression had significant VEGF immunoreactivity (p=0.008) and Ki-67 labeling index (p<0.001), but was not correlated with microvascular density within tumors (p=0.088). The high HIF-1 a expression was correlated with aberrant p53 accumulation with a marginal significance (p=0.056). The overall 5-year survival rate was 34.9%. The survival rate of patients with a high HIF-1 a expression was worse than that of patients with low-expression tumors (log-rank test, p=0.0001). High HIF-1 a expression was independent unfavorable factors although statistical significance is marginal in multivariate analysis. Conclusion: It is suggested that (1) high HIF-1 a expression in esophageal squamous cell carcinoma is associated with tumor hypoxia, or with genetic alteration in early carcinogenesis and progressive stages, (2) high HIF-1 a expression may be associated with intratumoral neovascularization through HIF-VEGF pathway, and (3) high HIF-1 a expression is associated with poor prognosis in patients with esophageal squamous cell carcinoma and may playa role as biomarker for regional lymph node metastasis.

Prognostic Value of the Expression of p53 and bcl-2 in Non-Small Cell Lung Cancer (비소세포폐암에서 p53과 bcl-2의 발현이 예후에 미치는 영향)

  • Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Keum, Joo-Seob;Kong, Gu;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.962-974
    • /
    • 1998
  • Background: Alteration of p53 tumor suppressor genes is most frequently identified in human neoplasms, including lung carcinoma. It is well known that bcl-2 oncoprotein protects cells from apoptosis. Recent studies have demonstrated that bcl-2 expression is associated with favorable prognosis for patients with non-small cell lung carcinoma. However, the precise biologic role of bcl-2 in the development of these tumors is still obscure. p53 and bcl-2 have important regulatory influence in the apoptotic pathway and thus their relationship is of interest in tumorigenesis, especially lung cancer. Purpose: The author investigated to know the prognostic significance of the expression of p53 and bcl-2 in radically resected non-small cell lung cancer. Method: 84 cases of formalin-fixed paraffin-embedded blocks from resected primary non-small cell lung cancer from 1980 to 1994 at Hanyang University Hospital were available for both clinical follow-up and immunohistochemical staining using monoclonal antibodies for p53 and bcl-2. Results : The histologic classification of the tumor was based on WHO criteria., and the specimens included 45 squamous cell carcinomas(53.6%), 28 adeonocarcinomas(33.3%) and 11 large cell carcinomas(13.1 %). p53 immunoreactivity was noted in 47 cases of 84 cases(56.0%). bcl-2 immunoreactivity was noted in 15 cases of 84 cases(17.9%). The mean survival duration was $64.23{\pm}10.73$ months in bcl-2 positive group and $35.28{\pm}4$. 39 months in bcl-2 negative group. The bcl-2 expression was significantly correlated with survival in radically resected non-small cell lung cancer patients(p=0.03). The mean survival duration was $34.71{\pm}6.12$ months in p53 positive group and $45.35{\pm}6.30$ months in p53 negative group(p=0.21). The p53 expression was not predictive for survival. There was no correlation between combination of the different status of p53 and bcl-2 expression in our study. Conclusions : The interaction and the regulation of new biologic markers, such as those involved in the apoptotic pathway, are complex. bcl-2 overexpression is a good prognostic factor in non-small cell lung cancer and p53 expression is not significantly associated with the prognostic factor in non-small cell lung cancer.

  • PDF

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Mobility Change around Neighborhood Parks and Green Spaces before and after the Outbreak of the COVID-19 Pandemic (COVID-19 발생 전·후 생활권 공원녹지 모빌리티 변화 분석)

  • Choi, Ga yoon;Kim, Yong gook;Kwon, Oh kyu;Yoo, Ye seul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.4
    • /
    • pp.101-118
    • /
    • 2023
  • During the COVID-19 pandemic, the utilization rate of neighborhood parks and green spaces increased significantly, and the outbreak served as an opportunity to highlight the values and functions of neighborhood parks and green spaces for urban residents. This study aims to empirically analyze how citizens' movement and the use of neighborhood parks and green spaces changed before and after COVID-19 and examine the social and spatial characteristics that affected these changes. As a research method, first, people's mobility around neighborhood parks and green spaces before and after the COVID-19 pandemic were compared using signal data from telecommunication carriers. Through the analysis of changes in residence time and movement volume, the movement characteristics of citizens after COVID-19 and changes in walking-based park visits were examined. Second, the factors affecting the mobility change in neighborhood parks and green spaces were analyzed. The social and spatial characteristics that affect citizens' visits to neighborhood parks and green spaces before and after COVID-19 were examined through correlation and multiple regression analysis. Subsequently, through cluster analysis, the types of living areas for the post-COVID era were classified from the perspective of the supply and management of neighborhood parks and green spaces services, and directions for improving neighborhood parks and green spaces by type were presented. Major research findings are as follows: First, since the outbreak of COVID-19, activities within 500m of the residence have increased. The amount of stay and walking movement increased in both 2020 and 2021, which means that the need to review the quantitative standards and attractions of neighborhood parks and green spaces has increased considering the changed scope of the walking and living area. Second, the overall number of visits to neighborhood parks and green spaces by walking has increased since the outbreak of COVID-19. The number of visits to neighborhood parks and green spaces centered on the house and the workplace increased significantly. The park green policy in the post-COVID era should be promoted by discovering underprivileged areas, focusing on areas where residential, commercial, and business facilities are concentrated, and improving neighborhood parks and green services in quantitative and qualitative terms. Third, it was found that the higher the level of park green service, the higher the amount of walking movement. It is necessary to use indicators that contribute to improving citizens' actual park green services, such as walking accessibility, rather than looking at the criteria for securing green areas. Fourth, as a result of cluster analysis, five types of neighborhood parks and green spaces were derived in response to the post-COVID era. This suggests that it is necessary to consider the socioeconomic status and characteristics of living areas and the level of park green services required in future park green policies. This study has academic and policy significance in that it has laid the basis for establishing neighborhood parks and green spaces policy in response to the post-COVID era by using various analysis methodologies such as carrier signal data analysis, GIS analysis, and statistical analysis.

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Comparison of Sea Level Data from TOPEX/POSEIDON Altimeter and in-situ Tide Gauges in the East Asian Marginal Seas (동아시아 주변해역에서의 TOPEX/POSEIDON 고도 자료와 현장 해수면 자료의 비교)

  • Youn, Yong-Hoon;Kim, Ki-Hyun;Park, Young-Hyang;Oh, Im-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.267-275
    • /
    • 2000
  • In an effort to assess the reliability of satellite altimeter system, we conducted a comparative analysis of sea level data that were collected using the TOPEX/POSEIDON (T/P) altimeter and the 10 tide gauge (TG) stations in the satellite passing track. The analysis was made using data sets collected from marginal sea regions surrounding the Korean Peninsula at T/P cycles of 2 to 230, which correspond to October 1992 to December 1998. Because of strong tidal activity in the study area, treatment of tidal errors is a very critical step in data processing. Hence in the computation of dynamic heights from the Tn data, we adapted the procedures of Park and Gamberoni (1995) to reduce errors associated with it. When these T/P data were treated, the alias periods of M$_2$, S$_2$, and K$_1$ constitutions were found at 62.1, 58.7, and 173 days. The compatibility of the T/P and TG data sets were examined at various filtering periods. The results indicate that the low-frequency signal of Tn data can be interpreted more safely with longer filtering periods (such as up to the maximum selected values of 200 days). When RMS errors for 200-day low-pass filter period was compared among the whole 10 tidal stations, the values spanned in the range of 2.8 to 6.7 cm. The results of correlation analysis at this filtering period also showed a strong agreement between the Tn and TG data sets over the whole stations investigated (e.g., P values consistently less than 0.0001). According to our analysis, we conclude that the analysis of surface sea level using satellite altimeter data can be made safely and reasonably long filtering periods such as 200 days.

  • PDF

PCA­based Waveform Classification of Rabbit Retinal Ganglion Cell Activity (주성분분석을 이용한 토끼 망막 신경절세포의 활동전위 파형 분류)

  • 진계환;조현숙;이태수;구용숙
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.211-217
    • /
    • 2003
  • The Principal component analysis (PCA) is a well-known data analysis method that is useful in linear feature extraction and data compression. The PCA is a linear transformation that applies an orthogonal rotation to the original data, so as to maximize the retained variance. PCA is a classical technique for obtaining an optimal overall mapping of linearly dependent patterns of correlation between variables (e.g. neurons). PCA provides, in the mean-squared error sense, an optimal linear mapping of the signals which are spread across a group of variables. These signals are concentrated into the first few components, while the noise, i.e. variance which is uncorrelated across variables, is sequestered in the remaining components. PCA has been used extensively to resolve temporal patterns in neurophysiological recordings. Because the retinal signal is stochastic process, PCA can be used to identify the retinal spikes. With excised rabbit eye, retina was isolated. A piece of retina was attached with the ganglion cell side to the surface of the microelectrode array (MEA). The MEA consisted of glass plate with 60 substrate integrated and insulated golden connection lanes terminating in an 8${\times}$8 array (spacing 200 $\mu$m, electrode diameter 30 $\mu$m) in the center of the plate. The MEA 60 system was used for the recording of retinal ganglion cell activity. The action potentials of each channel were sorted by off­line analysis tool. Spikes were detected with a threshold criterion and sorted according to their principal component composition. The first (PC1) and second principal component values (PC2) were calculated using all the waveforms of the each channel and all n time points in the waveform, where several clusters could be separated clearly in two dimension. We verified that PCA-based waveform detection was effective as an initial approach for spike sorting method.

  • PDF

MR Imaging Findings of Cortical Dysplasia of the Brain: Correlation with Pathologic Grades and Subtypes (뇌피질 이형성증의 자기공명영상소견: 병리적 등급 및 유형과의 연관성에 대하여)

  • Bae Ju Kwon;Kee-Hyun Chang;Chun-Kee Chung;Moon Hee Han;Yoon La Choi;Je G. Chi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • Purpose : Cortical dysplasia is known to be of variety of MR imaging findings. We attempted to classify MR imaging findings of cortical dysplasia into several types and to correlate those with histopathologic grades and subtypes. Materials and Methods : Preoperative MR images of 97 patients with pathologically-proven cortical dysplasia were retrospectively reviewed with knowledge of the diagnosis and operative sites. The patients were divided into MR-positive and MR-negative groups based on the presence or absence of MR imaging abnormalities. In MR-positive group, MR imaging features were arbitrarily classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types) on the basis of size of the gyrus and adjacent CSF space, cortical thickness, signal intensity of the subcortical white matter, and blurring of the gray-white matter junction. The pathologic findings were also retrospectively reviewed without knowledge of MR imaging findings and divided into three grades (mild, moderate, and severe) and two subtypes (nonballoon-cell and balloon-cell). Pathologic grades and subtypes we re compared between MR-positive and MR-negative groups. Four MR types of the MR-positive group were correlated with the pathologic grades and subtypes. Results : MR-positive and MR-negative groups consisted of 39 (40%) and 58 (60%) patients, respectively. Of the MR-positive group, atrophic type was seen in 13 patients (33 %), cortical-band type in 9 (23%), inward-rounding type in 9 (23%), and nonspecific type in 8 (21%). There was no significant difference in the pathologic grades between MR-positive and MR-negative groups, although MR-positive group tended to have higher pathologic grades than MR-negative group did. Balloon-cell subtype was found significantly higher in MR-positive group than in MR-negative group (p<0 .05): 21% (8/39) versus 5% (3/58). The inward-rounding type corresponded to the pathologically severe grade and balloon-cell subtype in 78% (7/9) and 56% (5/9) of the patients, respectively, while the atrophic type to the mild grade and nonballoon-cell subtype in 77% (10/13) and 100% (13/13), respectively. Conclusion : A variety of MR imaging abnormalities were found in 40% of the patients with cortical dysplasia and those were classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types), of which the inward-rounding type correlated well with the pathologically severe grade and balloon-cell subtype, whereas the atrophic type with the mild grade and nonballoon-cell subtype.

  • PDF

Novel LTE based Channel Estimation Scheme for V2V Environment (LTE 기반 V2V 환경에서 새로운 채널 추정 기법)

  • Chu, Myeonghun;Moon, Sangmi;Kwon, Soonho;Lee, Jihye;Bae, Sara;Kim, Hanjong;Kim, Cheolsung;Kim, Daejin;Hwang, Intae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.3-9
    • /
    • 2017
  • Recently, in 3rd Generation Partnership Project(3GPP), there is a study of the Long Term Evolution(LTE) based vehicle communication which has been actively conducted to provide a transport efficiency, telematics and infortainment. Because the vehicle communication is closely related to the safety, it requires a reliable communication. Because vehicle speed is very fast, unlike the movement of the user, radio channel is rapidly changed and generate a number of problems such as transmission quality degradation. Therefore, we have to continuously updates the channel estimates. There are five types of conventional channel estimation scheme. Least Square(LS) is obtained by pilot symbol which is known to transmitter and receiver. Decision Directed Channel Estimation(DDCE) scheme uses the data signal for channel estimation. Constructed Data Pilot(CDP) scheme uses the correlation characteristic between adjacent two data symbols. Spectral Temporal Averaging(STA) scheme uses the frequency-time domain average of the channel. Smoothing scheme reduces the peak error value of data decision. In this paper, we propose the novel channel estimation scheme in LTE based Vehicle-to-Vehicle(V2V) environment. In our Hybrid Reliable Channel Estimation(HRCE) scheme, DDCE and Smoothing schemes are combined and finally the Linear Minimum Mean Square Error(LMMSE) scheme is applied to minimize the channel estimation error. Therefore it is possible to detect the reliable data. In simulation results, overall performance can be improved in terms of Normalized Mean Square Error(NMSE) and Bit Error Rate(BER).