Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.
Kim, Chang-Bok;Cho, Jae-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
Journal of Magnetics
/
제17권2호
/
pp.153-157
/
2012
This study evaluated the ability of Diffusion-Weight Image (DWI), which is one of pulse sequences used in MRI based on the T2 weighted images, to detect samples placed within phantoms according to their size. Two identically sized phantoms, which could be inserted into the breast coil bilaterally, were prepared. Five samples with different sizes were placed in the phantoms, and the T2 weighted images and DWI were obtained. The Breast 2 channel coil of SIEMENS MAGNETOM Avanto 1.5 Tesla equipment was used for the experiments. 2D T2 weighted images were obtained using the following parameters: TR/TE = 6700/74 msec, Thickness/gap = 5/1 mm, Inversion Time (TI) = 130 ms, and matrix = $224{\times}448$. The parameters of DWI were that TR/TE = 8100/90 msec, Thickness/gap = 5/1 mm, matrix = $128{\times}128$, Inversion Time = 185 ms, and b-value = 0, 100, 300, 600, 1000 s/mm. The ratio of the sample volume on DWI compared to the T2 weighted images, which show excellent ability to detect lesions on MR images, was presented as the mean b-value. The measured b-value of the samples was obtained: 0.5${\times}$0.5 cm=0.33/0.34 square ${\times}$ cm (103%), 1${\times}$1 cm=1.28/1.25 square ${\times}$ cm (102.4%), 1.5${\times}$1.5 cm = 2.28/2.67 square ${\times}$ cm (85.39%), 2${\times}$2 cm=3.56/4.08 square ${\times}$ cm (87.25%), and 2.5${\times}$2.5 cm=7.53/8.77 square ${\times}$ cm (85.86%). In conclusion, the detection ability by the size of a sample was measured to be over 85% compared to T2 weighted image, but the detection ability of DWI was relatively lower than that of T2 weighted image.
Tooth mobility is an important part of a periodontal examination and represents a function of the persisting height of the alveolar bone and the width of the periodontal ligament. The purpose of this study was to evaluate the changes of the tooth mobility over 4 week-period following surgical therapy on the periodontal disease. Thirty five patients presenting with moderate periodontal pockets were selected and tooth mobility was measured at weekly intervals using Periotest (Siemens Co., Germany) beginning at the pre-operation examination and ending four weeks following the modified Widman Flap. All data were statistically analyzed using the one-way ANOVA test. The results were obtained as follows; 1. All teeth exhibited the greatest change in mobility at 1 week post-op, mobility generally decreasing with time. 2. Comparison of the weekly tooth mobility data regarding the 1st premolars showed significant differences only between weeks 1 (9.94) and 4 (6.14) (p<0.05). 3. Comparison of the weekly tooth mobility data regarding the 1st molar showed significant changes in the intervals between pre-op (6.49) and week 1 (11.22), pre-op and week 2 (9.37), weeks 1 and 3 (7.65), weeks 1 and 4 (5.62), and weeks 2 and 4 (p<0.05). 4. Comparison of the weekly tooth mobility data regarding the 2nd premolar and 2nd molar showed significant differences between pre-op (6.91, 8.60) and week 1 (11.02, 12.62), weeks 1 and 3 (8.00, 8.05), weeks 3 ad 4 (6.22, 6.71), and weeks 2 (9.34, 11.01) and 4 (p<0.05).
Tooth mobility is one of the most important clinical parameters in examination, diagnosis, prognosis and treatment planning procedure. In order to determine the differences of tooth mobility according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing, 90 male adults with periodontal disease and 10 male adults with periodontal health($25{\sim}45$ years old) were selected through clinical examinations including occlusal relationship, probing depth, attachment level, and bleeding on probing. On the mandibular anterior teeth, standard periapical radiographs were taken, and tooth mobility was measured by Periotest(Siemens Co., Germany). The radiographic bone level of individual tooth was evaluated as coronal 1/3, middle 1/3, and apical 1/3 to anatomical root length, and clinical crown length from incisal edge to bone level and clinical root length from bone level to root apex were measured with Boley gauge, and subsquently clinical crown/root ratio was calculated. The difference of tooth mobility(Periotest value) according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing was statistically analyzed by unpaired Student t-test. Tooth mobility was significantly higher in bleeding group than non-bleeding group on probing in the teeth radiographic bone level of middle 1/3, with clinical root length longer than 6mm, and with clinical crown/root ratio over 0.3(p<0.01). But there was no statistical difference in tooth mobility between bleeding group and non-bleeding group on probing in the teeth with radiographic bone level of apical 1/3, with short clinical root length less than 5mm, and with clinical crown/root ratio under 0.2(p>0.05). The results note that the tooth mobility depends on clinical root length, clinical crown/root ratio and gingival inflammation, and in the teeth with relatively good alveolar bone support gingival inflammation is one of the most important factors that affect tooth mobility.
Ljunggren, Stefan A.;Karlsson, Helen;Stahlbom, Bengt;Krapi, Blerim;Fornander, Louise;Karlsson, Lovisa E.;Bergstrom, Bernt;Nordenberg, Eva;Ervik, Torunn K.;Graff, Pal
Safety and Health at Work
/
제10권4호
/
pp.518-526
/
2019
Background: Additive manufacturing (AM) is a rapidly expanding new technology involving challenges to occupational health. Here, metal exposure in an AM facility with large-scale metallic component production was investigated during two consecutive years with preventive actions in between. Methods: Gravimetric analyzes measured airborne particle concentrations, and filters were analyzed for metal content. In addition, concentrations of airborne particles <300 nm were investigated. Particles from recycled powder were characterized. Biomonitoring of urine and dermal contamination among AM operators, office personnel, and welders was performed. Results: Total and inhalable dust levels were almost all below occupational exposure limits, but inductively coupled plasma mass spectrometry showed that AM operators had a significant increase in cobalt exposure compared with welders. Airborne particle concentrations (<300 nm) showed transient peaks in the AM facility but were lower than those of the welding facility. Particle characterization of recycled powder showed fragmentation and condensates enriched in volatile metals. Biomonitoring showed a nonsignificant increase in the level of metals in urine in AM operators. Dermal cobalt and a trend for increasing urine metals during Workweek Year 1, but not in Year 2, indicated reduced exposure after preventive actions. Conclusion: Gravimetric analyses showed low total and inhalable dust exposure in AM operators. However, transient emission of smaller particles constitutes exposure risks. Preventive actions implemented by the company reduced the workers' metal exposure despite unchanged emissions of particles, indicating a need for careful design and regulation of the AM environments. It also emphasizes the need for relevant exposure markers and biomonitoring of health risks.
The purpose of this study was to investigate the change of tooth mobility and bite force according to periodontal disease severity. Tooth mobility and biting force due to change of viscoelastic property of periodontium were influenced by inflammation of periodontal tissue. 30 patients participated in this study, the periodontal disease severity is evaluated with SBI and attachment loss. SBI and attachment loss were examined by periodontal probe. Tooth mobility was tested two times to each tooth using periotest (Siemens Co, Germany) and bite force was evaluated with MPM-3000 (Nihon Kohden Co, Japan). Statistical analysis was applied to correlation ($r^2$) and regression analysis. The obtained results were as follows : 1. As the attachment loss increased, tooth mobility increased with significance, and they had highly positive correlation ($r^2=0.68$) on entire dentition. 2. As the SBI increased, tooth mobility increased with significance, and they had positive correlation ($r^2=0.37$) on entire dentition. 3. As the attachment loss increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.42$) on maxillary anterior dentition but low negative correlation ($r^2=0.20$) on the other portion of dentition. 4. As the SBI increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.31$) on maxillary anterior dentition but low negative correlation ($r^2=0.16$) on the other portion of dentition. 5. As tooth mobility increased, bite force decreased with significance, and they had highly negative correlation ($r^2=0.32$) on maxillary anterior dentition but low negative correlation ($r^2=0.16$) on the other portion of dentition.
Background: The aim of this meta-analysis was to assess the efficacy of the apparent diffusion coefficient (ADC) value of diffusion-weighted MRI (DWI) for differentiating biliary tract cancer (BTC) from benign biliary tract diseases in Asians. Materials and Methods: We systematically searched Embase and PubMed prior to December 2014. Eight studies conducted in Asians met our predetermined inclusion criteria. Results: Our meta-analysis results showed that ADC values in BTC tissues were significantly lower than in benign biliary tract tissues (SMD = -1.54, 95%CI: -1.75~-1.33, P<0.001). Subgroup analysis based on the MRI machine type showed that the ADC values were consistent, accurate and reliable in the diagnosis of BTC when comparing cancer tissue vs. benign tissue under the Siemens 1.5 T/3.0 T, Philips 1.5 T/3.0 T, GE 1.5 T, and Toshiba 1.5 T types, respectively (all P<0.05). Further, ADC values were still consistent and accurate in the differential diagnosis of BTC under the b value of 800 and $1000s/mm^2$ (all P<0.05). Conclusions: Our findings supported potential clinical applications of DWI ADC values in differentiating BTC from benign biliary tract diseases in Asians.
최근 국제적으로 물관리의 차세대 개념으로서 지능형 물관리(Smart Water Grid)가 활발하게 논의되고 있다. 우리나라에서도 일부 학자들을 중심으로 이에 대한 개념이 도입되고 있다. 현재까지 정리된 지능형 물관리의 개념은 최근 급성장한 정보통신기술을 활용하여 기존에 비효율적으로 운영되는 물관리의 시스템을 획기적으로 개선하자는 것이다. 따라서 이론적으로는 물의 생산, 정수, 배송 그리고 이용과 처리에 이르는 전 과정을 실시간으로 통합하여 관리하는 것이 가능하다. 국제적으로는 IBM과 Siemens 등과 같이 정보통신과 물산업을 선도하는 기업 주도의 기술개발이 진행되는 단계이다. 2000년대 초반에는 용수수급의 효율화를 위한 장치개발에 주력하였으나, 현재에는 용수수급과 관련된 제반사항에 대한 기술적 통합시스템 구축으로 적용범위를 넓히고 있다. 우리나라에서도 도시인프라 자료의 통합관리와 수질 모니터링 시스템 구축이 추진되었으며, 2010년 12월 발표된 새만금종합개발계획에서는 본격적으로 활용을 검토하고 있다. 그러나 지능형 물관리의 기술적 통합시스템 전략은 곧 심각한 제도적 장벽에 직면할 것이다. 아무리 우수한 기술적 시스템이 개발된다고 하여도 제도적 기반의 구축이 없으면 국민경제에 도움이 되는 현실적용에는 한계가 있다. 기존에 확립된 물관리의 제도적 기반으로는 한정된 지역의 좁은 영역에서 활용될 수밖에 없다. 이것은 우리나라의 물관리가 기본적으로 법적, 제도적, 행정적 차원에서 분리되어 운영되고 있기 때문이다. 본 연구는 지능형 물관리가 지향하는 기술적인 통합시스템 구축이 당면할 제도적 한계를 도출하고 이를 극복하기 위한 정책적 방향을 제시하고자 한다. 또한 2009년 국회에 제출된 물관리기본법(안)에 지능형 물관리의 개념을 도입하는 방안을 모색하고자 한다.
본 논문은 조영 영상에서 유동적인 배경의 텍스쳐 분석을 통한 DSA(Digital subtraction Angiography: 디지털 혈관조영술)기반의 관상동맥 검출방법에 대해 기술한다. DSA 방법은 조영제를 투입하기 전에 촬영된 마스크 영상과 조영제 투입 후의 혈관 대비가 나타나는 라이브 영상과의 차이를 이용하여 빠르게 혈관 영역만을 검출하는 방법이다. 이 방법의 큰 단점은 배경의 움직임에 민감하고, 두 영상간의 지역적인 배경 명암 분포의 변화에 따라 오검출이 발생할 수 있다. 따라서 본 논문에서는 배경 텍스쳐의 유사도를 분석하여 움직임의 차이가 가장 작은 영상을 선택함으로써 배경의 움직임으로 인한 구조적인 문제를 해결하고, 선택된 영상의 지역적 명암 보정을 통해 혈관 영역만을 효과적으로 추출할 수 있는 방법을 제안한다. 실험 결과에서는 성능 평가를 위하여 다섯 환자의 임상 관상동맥 조영 영상을 사용 하였다. 제안하는 방법은 기존의 방법보다 배경을 혈관으로 인식하는 오 인식률에서 약 $2\%$정도의 안정적인 결과를 보여주며, 정확도는 증가하였음을 알 수 있다.
KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
/
제2B권3호
/
pp.115-124
/
2002
This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.