• 제목/요약/키워드: Side-Load

검색결과 1,240건 처리시간 0.031초

복합재 Iso-Grid 패널 제작 및 좌굴시험 (Composite Iso-Grid Panel Production and Buckling Test)

  • 유재석;김광수;장영순
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.51-55
    • /
    • 2004
  • A composite Iso-grid panel is manufactured and tested by compressive load. Vertical stringers and side stringers are joined with skin by secondary bonding using a liquid type adhesive. Bonding fixtures were developed to attach the stringers to skin. A-scan was done for inspection of secondary bonding region. The out of displacement field is visualized by shadow moire system. The strain and vertical displacement are measured by strain gages and L VDT (Linear Variable Differential Transformer). A local buckling is occurred at all grid sections. After that, the final failure is occurred. The strain of side stringer is much less than that of vertical stringer and skin. Due to the side stringer, the local buckling is delayed. Therefore the ratio of the first buckling to failure load is greater than that of vertical stringer stiffened panel.

  • PDF

영상어드미턴스에 의한 직접접지 배전방식에서의 역가압 지락사고 검출 (Back Fed Earth Fault Detection in Three Wire-Unigrounded Distribution-System By Zero Sequence Admittance)

  • 유명호;김일동;한홍석;박철원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.120-123
    • /
    • 1993
  • This paper presents the developing a new algorithm for detecting the Back fed Earth Fault in three wire-unigrounded distribution system by zero sequence admittance. So called "Backfed Earth Fault" of the electric power distribution line refers to a class of earth faults that the load-side line only is grounded, following after the distribution line broken into two parts, the source-side and the load-side. Because its mechanism differs from that of other earth faults, it is therefore, required to examine. This paper deals with the detailed software of the digital protective relay for Backfed earth fault. In order to prove that the proposed schemes is good, we performed off-line simulation using data from EMTP and ETSA(Electrcity Trust Of South Austrilia). It is shown that the suggested algorithm is never mal operated.

  • PDF

A Cost-Effective, Single-Phase Line-Interactive UPS System that Eliminates Inrush Current Phenomenon for Transformer-Coupled Loads

  • Bukhari, Syed Sabir Hussain;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.675-682
    • /
    • 2016
  • Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.

토양-러그 상호작용의 특성 해석 (Analysis of Soil-Lug Interaction Characteristics)

  • 조성찬;;이규승;;이용국;최중섭
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.179-186
    • /
    • 2000
  • Interactions between wheel lug surfaces and soil were analyzed through wheel motion. In this paper, lug surfaces such as trailing and leading lug sides and a lug face were analyzed and reported. The interactions between the surfaces and soil were expressed as the horizontal and vertical directions of resultant forces acting on the surfaces. There analysis indicated qualitatively that (1) the trailing lug side is mainly related to produce motion resistance and reaction to dynamic load, (2) the lug face is related to produce not only the motion resistance, the reaction to the dynamic load but also the traction and (3) the leading lug side is mainly related to produce the traction and the reaction to the dynamic load. Experiments were conducted to prove the results of the motion analysis. Normal and tangential forces acting on the surfaces were measured, and the traction, the motion resistance and the reaction to the dynamic load were calculated with wheel rotational and lug design angles. The experiments proved that the results of wheel motion analyses above mentioned as (1), (2) and obtained from the analysis were correct.

  • PDF

단열 도료 코팅 창호의 냉난방부하 특성분석 및 경제성 평가 (The Estimation of Heating, Cooling Load and Economical Efficiency Analysis of Insulation Paint Coating Windows)

  • 정열화;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.95-102
    • /
    • 2011
  • The purpose of study is to estimate heating, cooling load performance and economic efficiency in office building with applied the functional paint. this paint can reduced SHGC(Solar Heat Gain Coefficient) on the glazing surface by coating. In this study, estimated to compared with double glazing, low-e glazing, IP(Insulation Paint) and IPu(Insulation UV-Cut Paint) coating glazing. As a result of this study, 1)heating & cooling load Analysis, SHGC value and U-factor of double glazing is about 0.70 and 3.29($W/m^2K$). low-E glazing is about 0.65 and 2.70($W/m^2K$). Two-side it is about 0.27 and 3.25($W/m^2K$). When compared to double glazing, annual heating & cooling load of low-E glazing, Two-side IPu and IP paint coating glazing is 3,012MWh($124kWh/m^2$), 2,910MWh($120kWh/m^2$), 2,867MWh($118.4kWh/m^2$) and 2,867MWh($118.4kWh/m^2$). It i sreduced to 2.0%, 5.2%, 6.7%, and 6.7% respectively. 2)the estimation of economic efficiency, low-e glazing installed in office building can not recover the investment within a lifetime 40years. but IPu and IP paint, two-side coating in glazing, have a payback period of 13 years respectively.

암반에 근입된 현장타설말뚝의 주면지지력 (Side Shear Resistance of Drilled Shafts in Rock)

  • 권오성;김병철;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.611-618
    • /
    • 2005
  • In this research, the effect of rock mass weathering on the side shear resistance of drilled shaft socketed into weathered rock was investigated. For that, a database of 23 cast-in-place concrete piles with diameters varying from 400mm to 1,500mm were socketed into weathered igneous/meta-igneous rock at four different sites. The static axial load tests were performed to examine the resistant behavior of the piles, and a comprehensive field/laboratory testing program at the field test site was also performed to describe the in situ rock mass conditions quantitatively. No correlation was found between the compressive strengths of intact rock and the side shear resistance of weathered/soft rock. The ground investigation data regarding the rock mass conditions (e.g. $E_m,\;E_{ur},\;_{plm}$, RMR, RQD, j) was found to be highly correlated with the side shear resistance, showing the coefficients of correlation greater than 0.7 in most cases. Additionally, the applicability of existing methods for the side shear resistance of piles in rock was verified by comparison with the field test data. The existing empirical relations between the compressive strength of intact rock and the side shear resistance(Horvath (1982), Rowe & Armitage(1987) etc.) appeared to overestimated the side shear resistance of all piles tested in this research unless additional consideration on the effect of rock mass weathering or fracturing was applied. The existing methods which consider the effect of rock mass condition were modified and/or extended for weathered rock mass where mass factor j is lower than 0.1, and RQD is below 50%.

  • PDF

판토그래프 가혹공력하중에 대한 연구 (Investigation on Severe Aerodynamic Load Condition about Pantograph)

  • 황재호;이동호;정경렬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.361-366
    • /
    • 2001
  • The present study describes a practical estimation procedure about the pantograph under several severe aerodynamic load conditions. As the operating speed of the Korean Train Express(KTX) reaches 350km/h, structural safety at various conditions should be examined at the design stage. In the present study, a compact and reliable procedure is developed to get aerodynamic loads on each part of the pantograph regarding the typhoon condition, the train/tunnel interaction, the train/train interaction and the side wind condition. In the estimation procedure, 3-dimensional steady and unsteady CFD simulation around the high speed train facilitates assigning the external local flow condition around the pantograph. The procedure is verified using the results of the low speed wind tunnel test at JARI and applied to 7 flow conditions and 4 operation configurations.

  • PDF

FRP 선박 외판재의 연삭마모 특성에 관한 연구 (A study on abrasive wear characteristics of side plate of FRP ship)

  • 김병탁;고성위
    • 수산해양기술연구
    • /
    • 제44권3호
    • /
    • pp.250-256
    • /
    • 2008
  • Generally the side plate materials of FRP ship are composed of glass fiber and unsaturated polyester resin composites(GFRP composites). In this study, the effect of applied load and sliding speed on friction and wear characteristics of these materials were investigated at ambient temperature by pin-on-disc friction test. The cumulative wear volume, friction coefficient and wear rate of these materials for SiC abrasive paper were determined experimentally. The cumulative wear volume showed a tendency to increase nonlinearly with increase of sliding distance and was dependent on applied load and sliding speed for these composites. The friction coefficient of GFRP composites was increased as applied load increased at same sliding speed in wear test. It was verified by SEM photograph of worn surface that major failure mechanisms were microfracture, deformation of resin, cutting and cracking.

The Harmonic Current Mitigation of DFIG under Unbalanced Grid Voltage and Non-linear Load Conditions

  • Thinh, Quach Ngoc;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.83-84
    • /
    • 2011
  • This paper presents an analysis and a novel strategy for a doubly fed induction generator (DFIG) based wind energy conversion system under unbalanced grid voltage and non-linear load conditions. A proportional-resonant (PR) current controller is applied in both grid side converter (GSC) and rotor side converter (RSC). The RSC is controlled to mitigate the stator active power and the rotor current oscillations at double supply frequency under unbalanced grid voltage while the GSC is controlled to mitigate ripples in the dc-link voltage and compensate harmonic components of the network current. Simulation results using Psim simulation program are presented for a 2 MW DFIG to confirm the effectiveness of the proposed control strategy.

  • PDF

전력수요관리를 위한 원격부하제어시스템 개발

  • 윤갑구;문홍석
    • 전기의세계
    • /
    • 제44권6호
    • /
    • pp.27-36
    • /
    • 1995
  • 인구증가와 경제성장 및 문화발전에 수반하여 전력수요는 증가되고 사용시간과 장소가 집중되는 경향이다. 따라서 계절별, 일형별, 시간별, 지역별로 부하차이가 심해지고 부하율이 저하한다. 종래와 같이 예측되는 전력수요 곡선을 왜곡(distortion)시키지 않고 그대로 충족시킬 수 있는 설비를 계획하고 건설하여 운용하는 공급관리(SSM:Supply Side Management)에 의존할 때는 설비증설과 투자비가 증가하고 설비이용율이 저하하며 운전유지비가 증가하여 전력단가가 높아진다. 뿐만 아니라 지구환경을 해롭게 하는 CO$_{2}$ 배출량이 증가한다. 이러한 실저에서 설비투자비와 운전유지비를 절감하고 환경보전을 하기 위하여 수요곡선의 모양을 개선하도록 유도할 필요가 있다. 최근 세계적 추세는 부하관리와 효율향상 등으로 수요곡선 모양을 개선하는 수요관리(DSM:Demand-Side Management)에 치중하고 있다. 여기서는 전력수요고나리의 효과적 방법으로서 이른바 원격부하제어(RLC: Remote Load Control), 일명 직접부하제어(Direct Load Control)시스템으 개발기술을 검토한다. 개발코자 하는 RLC시스템은 일시정지시켜도 지장이 적은 수용가의 부하를 주기적으로 공급자가 제어할 수 있도록 하여 가변부하조성(Flexible Load Shape)을 하는 것이다. 가변부하조성은 필요시 운전예비율을 공급자와 수요자가 분담함으로서 전력수급의 안정을 도모하고 사회적 공급 지장비용을 경감시킬 수 있다.

  • PDF