• Title/Summary/Keyword: Side scanning

Search Result 311, Processing Time 0.027 seconds

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

  • Lee, Chaeyeong;Lee, Sangmin;Chung, Kwangzoo;Han, Youngyih;Chung, Yong Hyun;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.162-168
    • /
    • 2016
  • Proton therapy is increasingly being actively used in the treatment of cancer. In contrast to photons, protons have the potential advantage of delivering higher doses to the cancerous tissue and lower doses to the surrounding normal tissue. However, a range shifter is needed to degrade the beam energy in order to apply the pencil beam scanning technique to tumors located close to the minimum range. The secondary neutrons are produced in the beam path including within the patient's body as a result of nuclear interactions. Therefore, unintended side effects may possibly occur. The research related to the secondary neutrons generated during proton therapy has been presented in a variety of studies worldwide, since 2007. In this study, we measured the magnitude of the secondary neutron dose depending on the location of the detector and the use of a range shifter at the beam nozzle of the proton scanning mode, which was recently installed. In addition, the production of secondary neutrons was measured and estimated as a function of the distance between the isocenter and detector. The neutron dose was measured using WENDI-II (Wide Energy Neutron Detection Instruments) and a Plastic Water phantom; a Zebra dosimeter and 4-cm-thick range shifter were also employed as a phantom. In conclusion, we need to consider the secondary neutron dose at proton scanning facilities to employ the range shifter reasonably and effectively.

Light and Scanning Electron Microscopic Study on the Pelvic Epithelium of the Sheep Kidney (양(羊)의 신우상피에 대한 광학 및 주사전자현미경적 연구)

  • Kim, J.;Oh, S.J.;Chung, J.W.
    • Applied Microscopy
    • /
    • v.15 no.2
    • /
    • pp.98-110
    • /
    • 1985
  • This study was performed to clarify the morphological structures of the epithelia of the renal papilla, renal pelvis and ureter of the sheep (Ovis aries L.) through the light and scanning electron microscopes, Tissue specimens were taken from the renal papilla (common renal papilla and peripelvic column) and the renal pelvis (pelvis proper and pelvic pouch) of the kidney and the ureter. For the light microscopy, tissue blocks were fixed in 10 % neutral buffered formalin and embedded in paraffin wax, serially sectioned at a thickness of $6{\mu}m$. These sections were stained with hematoxylin-eosin and periodic acid-Schiff reaction. For the scanning electron microscopy, tissue blocks were prefixed in 1% glutaral-dehyde-1.5% paraformaldehyde solution and postfixed in 1% osmium tetroxide solution, dehydrated in graded alcohol, transferred to isoamyl acetate, and then dried by the critical point dryer (Polaron E 3000). These dried tissues were coated with gold and observed with a scanning electron microscope (JSM-35C), The results were as follows: The apex of the common renal papilla was lined with simple columnar epithelium having many microvilli on its luminal surface. Lateral portion of the papilla was lined with stratified epithelium $2{\sim}3$ layers thick, and its superficial cells were microvillar cells having many microvilli. The epithelium lining the peripelvic column was $1{\sim}2$ layers thick. The superficial layer was made of the microvillar cells, but a few microplica cells were appeared in the region near the pelvic pouch. The epithelium of the pelvic pouch was $1{\sim}2$ layered transitional type, and its superficial cells were microplica cells. The epithelia of the pelvis proper and ureter were $4{\sim}6$ layered transitional type, and their superficial cells were typical facet cells existing many round depressions and ridges of cell membranes of the luminal side.

  • PDF

Analysis of Chorion Structures in Kidney Mutant, Bombyx mori (신장형란에 있어서 난각구조의 해석)

  • 노시갑
    • Journal of Sericultural and Entomological Science
    • /
    • v.30 no.2
    • /
    • pp.88-95
    • /
    • 1988
  • The structure ki mutant chorion is described by the ultrastructural level with the scanning electron microscope. The micropyle on the anterior, posterior, leteral and dorsal side region surface patterns do not so much differ from ki mutant and normal strains. The surface structure of ventral side of ki mutant, which is the presumptive embryonic region in oocytes, were netted part corresponding to the boundary of follicle cells that is similar to lateral side structure of egg-shell. The eggshell thickness of ventral side on the ki mutant is mostly thicker. However, the structure of transverse section of normal and ki mutant egg-shell are composed of the outer, middle and inner layers. The ki not effects the formation of the lamellar layer in the egg-shell. It is observed that the characteristic structure in ki mutant egg chorion may be attributed to a areal specificity of epithelium in ventral side of egg-shell formation, and it affects the process of the accumulation of secreted chorionic material and the egg-shell architecture.

  • PDF

AN EXPERIMENTAL STUDY ON THE VASCULAR CHANGES OF RAT MOLAR PERIODONTAL LIGAMENT FOLLOWING ORTHODONTIC TOOTH MOVEMENT USING VASCULAR CORROSION CASTING METHOD (백서구치의 실험적 치아이동시 치근막 혈관변화에 관한 혈관주형법을 이용한 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.37-62
    • /
    • 1994
  • This study was undertaken to investigate the three dimensional vascular changes of periodontal ligament following orthodontic tooth movement. Experimental tooth movement was carried out in 96 Sprague-Dawley rats with the weight of 250g. They were divided into four experimental groups (each 24 rats). The left maxillary first molar was moved mesially with 25g force in group I, and with 75g force in group II. Each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days. In group III, 25g mesial force was applied for 3 days, and in group IV, 75g mesial force was applied for 3 days. Then the appliances were removed, and each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days from removal of appliance. The contralateral molars were used for control group. Casting media was injected via left ventricle and polymerized in warm water. After corrosion of surrounding soft tissue, three dimensional vascular changes were examined using scanning electron microscopy. The findings of this study were as follows: 1. Pressure side of group I and II showed degenerative vascular changes such as vascular compression, reduction of vasculature, leakage of casting media. But, regenerative changes were dominant after 7 days of tooth movement. Although the degenerative vascular changes were more severe in group II, which was exposed to heavy force, the timing of these changes was not different between two groups. 2. Periodontal vasculature was reestablished by the growth of new capillaries and their differentiation and union from the remaining periodontal vessels and vessels of alveolar bone marrow. Although vascular regeneration was more rapid in group I, which was exposed to light force, the vasculature was not fully normalized in both groups even after 21 days. 3. There was no remarkable changes in tension side of group I and II, but looping of capillary, new capillary growth, dilation of vessels, redirection of vessels in the direction of tensile force were occurred. 4. In pressure side of group III and IV, in which appliance was removed after 3 days of orthodontic force, bone resorption was continued even after removal of appliance. Regeneration of vasculature was initiated after 1-6 hours, and it was more rapid in group III than group IV. In both groups, the vasculature was not fully normalized even after 21 days. 5. After removal of appliance, tension side of group III and IV showed vascular compression and loss of vasculature.

  • PDF

An Investigation on Gridline Edges in Screen-Printed Crystalline Silicon Solar Cells

  • Kim, Seongtak;Park, Sungeun;Kim, Young Do;Kim, Hyunho;Bae, Soohyun;Park, Hyomin;Lee, Hae-Seok;Kim, Donghwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.490.2-490.2
    • /
    • 2014
  • Since the general solar cells accept sun light at the front side, excluding the electrode area, electrons move from the emitter to the front electrode and start to collect at the grid edge. Thus the edge of gridline can be important for electrical properties of screen-printed silicon solar cells. In this study, the improvement of electrical properties in screen-printed crystalline silicon solar cells by contact treatment of grid edge was investigated. The samples with $60{\Omega}/{\square}$ and $70{\Omega}/{\square}$ emitter were prepared. After front side of samples was deposited by SiNx commercial Ag paste and Al paste were printed at front side and rear side respectively. Each sample was co-fired between $670^{\circ}C$ and $780^{\circ}C$ in the rapid thermal processing (RTP). After the firing process, the cells were dipped in 2.5% hydrofluoric acid (HF) at room temperature for various times under 60 seconds and then rinsed in deionized water. (This is called "contact treatment") After dipping in HF for a certain period, the samples from each firing condition were compared by measurement. Cell performances were measured by Suns-Voc, solar simulator, the transfer length method and a field emission scanning electron microscope. According to HF treatment, once the thin glass layer at the grid edge was etched, the current transport was changed from tunneling via Ag colloids in the glass layer to direct transport via Ag colloids between the Ag bulk and the emitter. Thus, the transfer length as well as the specific contact resistance decreased. For more details a model of the current path was proposed to explain the effect of HF treatment at the edge of the Ag grid. It is expected that HF treatment may help to improve the contact of high sheet-resistance emitter as well as the contact of a high specific contact resistance.

  • PDF

INFLUENCE OF A FUNCTIONAL LOADING TIME ON BONE FORMATION AROUND OSSEOINTEGRATED TITANIUM IMPLANTS IN ADULT DOGS (성견에서 골유착성 타이타늄 임프란트의 기능적 노출 시기가 주위의 골형성에 미치는 영향)

  • Yang Ja-Ho;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.55-74
    • /
    • 1991
  • The purpose of this study was to investigate the influence of early functional load around osseointegrated titanium implants. 24 titanium plasma spray coated implants (ITI HS-type) were placed into the previously extracted site in the mandible of six adult dogs. The implants were divided into three groups : the control group was the implants without abutment during the experimental period; the experimental group I was loaded by connecting the contoured abutment after 6 weeks of healing; the experimental group II was loaded after 12 weeks of healing: and the mandibular second premolar and surrounding tissues were selected for natural tooth group to compare the implanted group. All dogs were injected intravenously tetracycline, alizarin red S, and calcein for bone labeling. After the experimental period of 18 weeks, the dogs were sacrificed and longitudinal sections of the bone-implant interface were cut and observed using light microscope, scanning electron microscope, and fluorescence microscope. The results of the study were as follows: 1. Light and scanning electron microscopically, all implant surfaces were well contact with bone tissue at the cortical layer, but some areas of cancellous bone were not contact directly. 2. Fluorescence microscopically, number and size of the new secondary osteons around the implant were increased than those of the natural tooth. 3. Fluorescence microscopically, linear and concentrical fluorescence was observed at or near the surface of all implants, and the bone formation and remodeling of the implants loaded after 6 week of healing were great, and unloaded implants were worst. 4. Fluorescence microscopically, endosteal bone formation was greater than periosteal bone formation at or near the implants. 5. Fluorescence microscopically, number and size of linear and concentric fluorescence was increased at the lingual side than the buccal side of the loaded implants. The result of the study indicate the possibility of the early load to the implant via a prosthesis.

  • PDF

Relations Between Impact Damage and Ply Angle Under Same Impact Energy Condition (同一한 衝擊에너지 條件下의 CFRP 斜交積層板의 衝擊損傷과 配向角의 關係)

  • ;笠野英秋
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1824-1832
    • /
    • 1992
  • This study investigated the compressive Young's modulus and the impactinduced damage of CFRP angle-ply laminate under same impact energy condition. The specimens of angle-ply laminate composites [0.deg.$_{6}$/ .theta..deg.$_{10}$/ 0.deg.$_{6}$] with .theta..deg. =30.deg., 45.deg., 60.deg. and 90.deg. were employed, and damaged by steel balls of diameter of 5mm and 10mm propelled by air gun type impact testing machine. The impact damaged zones were observed through a scanning acoustic microscope(SAM), and their cross-sections were observed through a scanning electron microscope(SEM). The compressive Young's moduli before and after impact were measured, and compared with the theoretical values calculated. The results obtained were as follows: (1) The damage areas on the interfacial boundaries showed more severe change on the back side interface than on the impact side interface with increasing ply-angle. (2) The damage areas on the interfacial boundaries became larger with increasing impact velocity or ply-angle. (3) The impact damaged zone showed the delamination on the interfacial boundaries and transverse cracks inside laminas. (4) The impact damaged zone was affected by the impactor size and speed or ply-angle under same impact energy condition. (5) Compressive Young's moduli before and after impact were lower than theoretical value, but showed a similar change according to ply-angle. (6) Compressive Young's moduli after impact were higher than those before impact, but there was no remarkable change in apparent compressive modulus after impact.t.act.

A Morphological Study on the Androconia of the Lycaenidae(Insecta: Lepidoptera)in Korea (한국산 부전나비과(곤충강:나비목)의 발향린에 관한 형태학적 연구)

  • 이종욱;류성만;이미경
    • Korean journal of applied entomology
    • /
    • v.37 no.1
    • /
    • pp.39-48
    • /
    • 1998
  • To know whether there is any androconia on Korean Lycaenidae, studies were carried out with Korean Lycaenid butterflies for their types and distribution pattern with the aid of scanning electron microscope. As the results, androconia was observed from 8 species; Niphanda fusca (B. et G.), Pseudozizeeria maha (K.), Zizina otis (F.), Everes argiades (P.), Celasrtina argiolus (L.), Maculinea arionides (S.), M. teleius (B.) and Lycaeides argyronomon (B.). Androconia was not found only from males, and it was observed on both dorsal and ventral surfaces of fore wings and on ventral surface of hind wings. Androconia was found to be distributed mainly on the area between the median and anal venis. General structure of androconia on Korean Lycaenids was rather simple with laminar and foot stalk. However, 2 types of androconia were observed from 2 species, Pseudozizeeria maha and Everes argiades, while only one type was observed from other 6 species. The foot stalks of androconia on Niphanda fusca under the tribe Niphandini is located on the ventral surface of laminar and hidden from dorsal view, while one end of that on all other 7 species belong to the tribe Polyommatini is attached to the lower side of laminar and shown from both side.

  • PDF

A Study on the Impact-Induced Damage in CFRP Angle-ply Laminates (CFRP 사교적층판의 충격손상에 관한 연구)

  • 배태성;입야영;양동률
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.237-247
    • /
    • 1993
  • Carbon fiber reinforced plastics(CFRP) have gained increased application in aerospace structures because of their specific strength and stiffness, but are sensitive to impact-induced damage. An experimental investigation was carried out to evaluate the impact resistance of CFRP according to the ply angle. The specimens of angle ply laminate composites were employed with [0.deg. $_{6}$/ .deg.$_{10}$/0.deg.$_{6}$], in which 6 kinds of ply angle such as .deg.=15.deg., 30.deg., 45.deg., 60.deg., 75.deg. and 90.deg. were selected. The impact tests were conducted using the air gun type impact testing machine by steel balls of diameter of 5 mm and 10 mm, and impact-induced damages were evaluated under same impact speed of V=60m/s. The impact damaged zones were observed through a scanning acoustic microscope (SAM). The obtained results were summarized as follows: (1) Delaminations on the interfacial boundaries showed th directional characteristics to the fiber directions. The delamination area on the impact side (interface A) was considerably smaller compared to that of the opposite side (interface B). (2) Cracks corresponding to other delaminations than those mentioned in SAM photographs were also seen on the impact damaged zone. (3) The delamination patterns were affected by the ply-angle, the dimensions of the specimen, and the boundary conditions. (4) The impact damaged zone showed zone showed the delamination on the interfacial boundaries, transverse shear cracks of the surface layer, and bending cracks of the bottom layer.r.r.r.

A SEM STUDY OF RADIATION EFFECTS ON THE RAT MOLAR ENAMEL FORMATION (방사선조사가 백서 구치 법랑질형성에 미치는 영향에 관한 주사전자현미경적 연구)

  • Lee Kyung-Ho;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.409-422
    • /
    • 1995
  • The purpose of this study was to investigate the effects of radiation on the formation of rat molar enamel at the developmental stage. The experimental animals were divided into five groups and were irradiated single dose of 396cGy ; 1 st group on 14th day of gestation, 2nd group on 19th day of gestation, 3rd group on 3 days after birth, 4th group on 8 days after birth, 5th group on 28 days after birth. The control and 1, 2, 3, and 4th experimental groups were sacrificed on 2, 4, and 6 weeks and the 5th groups were sacrificed on 1 day and 2 weeks after irradiation. Distal 1/2 and occlusal 1/3 enamel surface of lingual side of lingual cusp, and fractured surface of lingual side of lingual cusp in a longitudinal direction of the mandibular first molar were examined using scanning electron microscope. The following results were obtained. 1. The roughness of enamel surface and enamel hypoplasia were increased in a sequence of 4th, 1st, 2nd, and 3rd experimental group, and the enamel cracks were increased in the 1st and 2nd experimental group. 2. The pattern of enamel hypoplasia had a network form on the 1st and 2nd experimental group, and appeared a linear shape on the 3rd experimental group, and then the crator-like enamel defects were observed in all experimental groups (especially 1st and 2nd experimental group) except 5th. 3. Dentinoenamel junction showed the clear-cut and straight appearance except 5th experimental group. 4. There was no significant difference between 5th experimental and control group.

  • PDF