• 제목/요약/키워드: Side scanning

검색결과 313건 처리시간 0.023초

새우조망에 의한 어업구역의 인위적인 영향에 대한 선행연구 (A primary study on the effect of artificial disturbance on a fishing area by shrimp beam trawl)

  • 차봉진;윤상필;정래홍;김성길;이재성;윤원득;신종근
    • 수산해양기술연구
    • /
    • 제45권4호
    • /
    • pp.223-233
    • /
    • 2009
  • It has been considered that fishing areas for shrimp beam trawl have been in ruin because Korean local governments have permitted trawling into the areas limited by the fisheries local regulations from 1994. Physical and biological effects of the trawling were investigated in the study. Physical effects were investigated by optical methods such as trawling tracking by side scan sonar and comparing the gear both before and after trawling. Biological aspects were investigated by grab sampling of benthic animals, concentration of trace metals in sediment and a flux evaluation of ${NH_4}^+,\;{PO_4}^-,\;and\;SiO_2$ by coring. The fishing activity had physical impacts on the seabed but these recovered naturally in less than fourty days naturally, which increased the benthic biodiversity, increases the trace metal concentration of and nutrient flux into the seawater, especially phosphate and silicate. This method and these results can help in further studies looking for disturbances by fishing.

염산피밤피실린의 마이크로캅셀에 관(關)한 약제학적(藥劑學的) 연구(硏究) (Pharmaceutical Studies on Microencapsulated Pivampicillin Hydrochloride)

  • 이완하;지웅길;이영환;김상린
    • Journal of Pharmaceutical Investigation
    • /
    • 제15권2호
    • /
    • pp.53-62
    • /
    • 1985
  • Pivampicillin hydrochloride is a kind of broad spectrum antibiotics with bactericidal action, and is used in many countries, although it has bitter taste, unpleasant odour and side effects of irritating gastric mucosa, nausea, penicillin allergy, etc. For the improvement of such side effects of pivampicillin hydrochloride, microcapsules, with wall of ethylcellulose, have been prepared by coacervation method. The shape was observed through the scanning electron microscope, the release of the drug into an aqueous medium was studied and the effects of core: ethylcellulose ratio were interpreted as well as making sensory evaluation of taste and odour. There was decreasing trend in dissolution rate of the drug with the increase of core: ethylcellulose ratios, and the smaller microcapsules released their contents more rapidly. A linear relationship was established between the amount of ethylcellulose and the time for 60% release of the drug, and the release pattern was found to have similar characteristics to the release of the drug from an insoluble porous matrix. The release of the drug in the artificial intestinal fluids (pH 6.8) was found to be similar to that in water, while the release in the artificial gastric juice (pH 1.2) was slightly slower. Bioavailability of microcapsule was compared with that of pivampicillin hydrochloride in rabbits using serum concentration and urinary excretion measurements. Microcapsule gave showed slightly higher serum level than pivampicillin hydrochloride from 2 hours after administration, while no significant difference was observed in the accumulated urinary excretion rate between pivampicillin hydrochloride and microcapsule. The ulcer index of pivampicillin hydrochloride administered group was 2.6, and microcapsule administered group was 1.5, while control group was 0.8. Therefore it may be concluded that microencapsulation of pivampicillin hydrochloride is a useful pharmaceutical approach to protect the gastrointestinal tract from being injured by direct contact of pivampicillin hydrochloride without any significant difference of bioavailability.

  • PDF

Periodontal regeneration with nano-hyroxyapatite-coated silk scaffolds in dogs

  • Yang, Cheryl;Lee, Jung-Seok;Jung, Ui-Won;Seo, Young-Kwon;Park, Jung-Keug;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.315-322
    • /
    • 2013
  • Purpose: In this study, we investigated the effect of silk scaffolds on one-wall periodontal intrabony defects. We conjugated nano-hydroxyapatite (nHA) onto a silk scaffold and then seeded periodontal ligament cells (PDLCs) or dental pulp cells (DPCs) onto the scaffold. Methods: Five dogs were used in this study. Bilateral 4 mm${\times}$2 mm (depth${\times}$mesiodistal width), one-wall intrabony periodontal defects were surgically created on the distal side of the mandibular second premolar and the mesial side of the mandibular fourth premolar. In each dog, four of the defects were separately and randomly assigned to the following groups: the PDLCcultured scaffold transplantation group (PDLC group), the DPC-cultured scaffold transplantation group (DPC group), the normal saline-soaked scaffold transplantation group, and the control group. The animals were euthanized following an 8-week healing interval for clinical, scanning electron microscopy (SEM), and histologic evaluations. Results: There was no sign of inflammation or other clinical signs of postoperative complications. The examination of cellseeded constructs by SEM provided visual confirmation of the favorable characteristics of nHA-coated silk scaffolds for tissue engineering. The scaffolds exhibited a firm connective porous structure in cross section, and after PDLCs and DPCs were seeded onto the scaffolds and cultured for 3 weeks, the attachment of well-spread cells and the formation of extracellular matrix (ECM) were observed. The histologic analysis revealed that a well-maintained grafted volume was present at all experimental sites for 8 weeks. Small amounts of inflammatory cells were seen within the scaffolds. The PDLC and DPC groups did not have remarkably different histologic appearances. Conclusions: These observations indicate that nHA-coated silk scaffolds can be considered to be potentially useful biomaterials for periodontal regeneration.

Synthesis and Characterization of banana-shaped achiral molecules

  • Lee, Chong-Kwang;Lee, Chong-Kwang;Kwon, Soon-Sik;Kim, Tae-Sung;Shin, Sung-Tae;Choi, Suk;Choi, E-Joon;Kim, Sea-Yun;Kim, Jae-Hoon;Zin, Wang-Choel;Kim, Dae-Cheol;Chien, Liang-Chy
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.504-508
    • /
    • 2003
  • New banana-shaped achiral compounds, 4-chloro-1,3-phenylene bis [4-4(3-fluoro-9-alkenyloxy) phenyl-iminomethylbenzoate]s and 4-chloro-1,3-phenylene bis [4-4-(3-fluoro-10-alkanyloxy) phenyliminomethyl benzoate]s were synthesized by varying the substituent (X=H, F, or Cl); their electrooptical properties are described. The smectic phases, including a switchable chiral smectic C ($SmC^{\ast}$) phase, were characterized by differential scanning calorimetry, polarizing optical microscopy, and triangular method. The presence of vinyl end group at the terminals of linear side wings in the banana-shaped molecules induced a decrease in melting temperature. The smectic phase having the undecenyloxy group such $as-(CH_2)_9CH=CH_2$ showed ferroelectric switching, and its value of spontaneous polarization on reversal of an applied electric field was 2250 $nC/cm^2$, while the value of spontaneous polarization of the smectic phase having the decanyloxy group such as $-(CH2)_9CH_3$ was 3700 $nC/cm^2$. We could obtain the ferroelectric phase with low isotropic temperature by varying the end group at the terminals of linear side wings in the banana-shaped achiral molecules.

  • PDF

감마선을 이용한 단열배관의 실시간 두께측정시스템 개발 (Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray)

  • 장지훈;김병주;김기동;조경식
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.500-507
    • /
    • 2002
  • 본 연구에서는 감마선과 섬광체 및 광 다이오드로 구성된 64 채널의 선형 디텍터 어레이를 이용하여 보온재로 싸인 배관의 두께를 실시간으로 측정하는 시스템을 개발하였다. 본 측정시스템은 감마선원으로 Ir-192를 사용하였으며, 디텍터는 BGO 섬광체와 광다이오드로 구성하였다. Ir-192 방사선원은 배관의 한쪽 편에, 그리고 디텍터 어레이는 배관을 중심으로 그 반대편에 위치하며 컴퓨터로 제어되는 주행 시스템에 실려 배관을 따라 이송되는 동안 배관과 단열재를 투과한 방사선의 강도는 각 디텍터에서 측정된다. 측정된 디텍터 어레이의 출력은 증폭기에서 증폭된 후 케이블에 의해 컴퓨터로 전송되며 주행시스템이 진행하는 동안 컴퓨터는 수집된 신호를 분석 및 계산하여 실제의 두께를 나타내며 주사간격을 1mm로 할 경우의 최대 측정속도는 분당 120cm이다.

코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성 (Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge)

  • 이수환;이동훈
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

Planar Type Flexible Piezoelectric Thin Film Energy Harvester Using Laser Lift-off

  • Noh, Myoung-Sub;Kang, Min-Gyu;Yoon, Seok Jin;Kang, Chong-Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.489.2-489.2
    • /
    • 2014
  • The planar type flexible piezoelectric energy harvesters (PEH) based on PbZr0.52Ti0.48O3 (PZT) thin films on the flexible substrates are demonstrated to convert mechanical energy to electrical energy. The planar type energy harvesters have been realized, which have an electrode pair on the PZT thin films. The PZT thin films were deposited on double side polished sapphire substrates using conventional RF-magnetron sputtering. The PZT thin films on the sapphire substrates were transferred by PDMS stamp with laser lift-off (LLO) process. KrF excimer laser (wavelength: 248nm) were used for the LLO process. The PDMS stamp was attached to the top of the PZT thin films and the excimer laser induced onto back side of the sapphire substrate to detach the thin films. The detached thin films on the PDMS stamp transferred to adhesive layer coated on the flexible polyimide substrate. Structural properties of the PZT thin films were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). To measure piezoelectric power generation characteristics, Au/Cr inter digital electrode (IDE) was formed on the PZT thin films using the e-beam evaporation. The ferroelectric and piezoelectric properties were measured by a ferroelectric test system (Precision Premier-II) and piezoelectric force microscopy (PFM), respectively. The output signals of the flexible PEHs were evaluated by electrometer (6517A, Keithley). In the result, the transferred PZT thin films showed the ferroelectric and piezoelectric characteristics without electrical degradation and the fabricated flexible PEHs generated an AC-type output power electrical energy during periodically bending and releasing motion. We expect that the flexible PEHs based on laser transferred PZT thin film is able to be applied on self-powered electronic devices in wireless sensor networks technologies. Also, it has a lot of potential for high performance flexible piezoelectric energy harvester.

  • PDF

Bioactivity of endodontic biomaterials on dental pulp stem cells through dentin

  • Javid, Bahar;Panahandeh, Narges;Torabzadeh, Hassan;Nazarian, Hamid;Parhizkar, Ardavan;Asgary, Saeed
    • Restorative Dentistry and Endodontics
    • /
    • 제45권1호
    • /
    • pp.3.1-3.10
    • /
    • 2020
  • Objectives: This study investigated the indirect effect of calcium-enriched mixture (CEM) cement and mineral trioxide aggregate (MTA), as 2 calcium silicate-based hydraulic cements, on human dental pulp stem cells (hDPSCs) through different dentin thicknesses. Materials and Methods: Two-chamber setups were designed to simulate indirect pulp capping (IPC). Human molars were sectioned to obtain 0.1-, 0.3-, and 0.5-mm-thick dentin discs, which were placed between the 2 chambers to simulate an IPC procedure. Then, MTA and CEM were applied on one side of the discs, while hDPSCs were cultured on the other side. After 2 weeks of incubation, the cells were removed, and cell proliferation, morphology, and attachment to the discs were evaluated under scanning electron microscopy (SEM). Energy-dispersive X-ray (EDXA) spectroscopy was performed for elemental analysis. Alkaline phosphatase (ALP) activity was assessed quantitatively. The data were analyzed using the Kruskal-Wallis and Mann-Whitney tests. Results: SEM micrographs revealed elongated cells, collagen fibers, and calcified nucleations in all samples. EDXA verified that the calcified nucleations consisted of calcium phosphate. The largest calcifications were seen in the 0.1-mm-thick dentin subgroups. There was no significant difference in ALP activity across the CEM subgroups; however, ALP activity was significantly lower in the 0.1-mm-thick dentin subgroup than in the other MTA subgroups (p < 0.05). Conclusions: The employed capping biomaterials exerted biological activity on hDPSCs, as shown by cell proliferation, morphology, and attachment and calcific precipitations, through 0.1- to 0.5-mm-thick layers of dentin. In IPC, the bioactivity of these endodontic biomaterials is probably beneficial.

초지법에 따른 한지의 물성비교 (Comparison of Physical Properties of Hanjis Made by Different Sheet Forming Processes)

  • 최태호;조남석;최인호;정택상
    • 펄프종이기술
    • /
    • 제33권4호
    • /
    • pp.21-27
    • /
    • 2001
  • Korean traditional paper (Hanji) making technology has adopted two kinds of sheet forming processes, which called "Oebal-choji": and "Ssangbal-choji". The sheet forming process of Oebal-choji is an original method developed in Korea. At first, paper stock is dipped onto the mold and flow away in the forward direction. Then, paper stock is scooped again and rhythmically rocked from side to side, this work is repeated several times. Through this operation the fibers intertwine and paper layers are formed. Ssangbal-choji is almost same as the Nagashizuki, which used in Japan. In this method, paper stock is scooped onto the mold and rhythmically rocked backwards and forwards several times, the water drains slowly through the bamboo screen and then sheet is formed. Tamezuki method is used in Japan and China. This is a method in which the mold is dipped into the paper stock once and left to drain. In the Ssangbal-choji and Nagashizuki methods, the most of excess solution is cast out while in the Tamezuki all of it is allowed to drain through the mold. This study was carried out to investigate the physical properties of the Hanjis that were made by Oebal-choji, Ssangbal-choji, Nagashizuki, and Tamezuki sheet forming processes. The results were follows; Physical properties of the Oebal-choji Hanji were better than those of Ssangbal-choji, Nagashizuki, and Tamezuki. Oebal-choji Hanji made little difference of paper strength between MD and CD, but Ssangbal-chjo and Nagashizuki Hanjis made wide difference. And there are no difference of paper strength between MD and CD on the Tamezuki Hanji. On the confocal laser scanning microscopy (CLSM) observation of the Hanjis, Oebal-choji made well crossed fiber orientation than those of other forming processes.r forming processes.

  • PDF

송수신 모드 배열 코일 와전류 탐촉자의 특성 연구 및 이를 이용한 표면검사 (Study on Characteristics of Eddy Current Array Coil Operated in Transmit-Receive Mode and Surface Inspection Using This Probe)

  • 이태훈;지동현;조찬희;김인철
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.21-28
    • /
    • 2017
  • 배열 와전류 기술은 2차원적으로 나란히 정열된 다수의 와전류 코일로 구성된 탐촉자 면적에 대하여 기계적인 이동없이 전기적으로 주사할 수 있다. 단일 코일을 사용하는 와전류 기술과 비교하여 탐촉자가 한 번의 이동으로 넓은 영역을 검사할 뿐만 아니라 데이터 해석이 용이하여 검사 속도와 신뢰성을 향상시키는 장점이 있다. 이번 연구에서는 $2{\times}16$ 코일 배열의 배열 와전류 탐촉자와 순차적으로 송수신 코일을 선택하고 송수신 모드로 동작시키는 다중화기기를 개발하였다. 이 탐촉자를 이용하여 다양한 종류의 시편을 제작하여 표면검사를 수행하고, 와전류 신호 및 C-scan을 이미지 분석을 통해 송수신 모드 배열 와전류 기술의 특성에 대해 연구하였다.