• Title/Summary/Keyword: Side condition

Search Result 1,840, Processing Time 0.031 seconds

Balance and Gait Patterns in Patients With Hemiplegia Wearing Anterior and Posterior Leaf Springs (편마비 환자에서 전방형과 후방형 플라스틱 단하지 보조기의 효과 비교)

  • Park, So-Yeon;Park, Jung-Mi
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.77-91
    • /
    • 2002
  • Asymmetrical stance posture, balance, and gait disturbance are common problems in hemiplegic patients. Posterior leaf springs (PLS) are frequently prescribed to correct these problems. Recently, anterior leaf springs (ALS) have also been prescribed, but only limited studies have been performed to investigate the effects of ALS. The purpose of this study was to compare the effects of three conditions, i.e., wearing an ALS, wearing a PLS, and not wearing an AFO (ankle foot orthosis),: on 1) the distribution of weight bearing on the affected side, 2) standing balance, and 3) the gait patterns of hemiplegic patients. Eleven hemiplegic patients (10 men and 1 woman) participated in this study. The data were analyzed by the Friedman test. The results were as follows: 1) More weight bearing on the affected leg was observed in the ALS and PLS conditions than in the condition without an AFO. No significant difference between the ALS and PLS conditions was found. 2) There were statistically significant differences in the composite equilibrium scores (CES) among the three conditions. The CES in the PLS condition was significantly higher than in the ALS condition or the condition without an AFO. 3) Gait patterns improved significantly in the ALS and PLS conditions. No statistically significant difference between the ALS and PLS conditions was found. These results suggest that both ALS and PLS effectively improve the distribution of weight bearing on the affected side, standing balance, and gait patterns of hemiplegic patients. Further study using three-dimensional kinematic analysis and dynamic electromyography is needed to support these findings.

  • PDF

The Maximum Power Condition of the Endo-reversible Cycles (내적가역 사이클의 최대출력 조건)

  • 정평석;김수연;김중엽;류제욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.172-181
    • /
    • 1993
  • Pseudo-Brayton cycle is defined as an ideal Brayton cycle admitting the difference between heat capacities of working fluid during heating and cooling processes. The endo-pseudo-Brayton cycle which is a pseudo-Brayton cycle with heat transfer processes is analyzed with the consideration of maximum power conditions and the results were compared with those of the endo-Carnot cycle and endo-Brayton cycle. As results, the maximum power is an extremum with respect to the cycle temperature and the flow heat capacities of heating and cooling processes. At the maximum power condition, the heat capacity of the cold side is smaller than that of heat sink flow. And the heat capacity of endo-Brayton cycle is always between those of heat source and sink flows and those of the working fluids of pseudo-Brayton cycle. There is another optimization problem to decide the distribution of heat transfer capacity to the hot and cold side heat exchangers. The ratios of the capacies of the endo-Brayton and the endo-pseudo-Braton cycles at the maximum power condition are just unity. With the same heat source and sink flows and with the same total heat transfer caqpacities, the maximum power output of the Carnot cycle is the least as expected, but the differences among them were small if the heat transfer capacity is not so large. The thermal efficiencies of the endo-Brayton and endo-Carnot cycle were proved to be 1-.root.(T$_{7}$/T$_{1}$) but it is not applicable to the pseudo-Brayton case, instead it depends on comparative sizes of heat capacities of the heat source and sink flow.w.

A Study of the Influence of Strain Gauge Location and Contact Conditions by Loading Platens on the Mechanical Behavior of Rock Specimens (암석공시체의 역학적 거동 해석에 미치는 변형율게이지 위치 및 단면구속 영향에 대한 연구)

  • 정교철
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.215-224
    • /
    • 1998
  • In this study, total strain was measured by LVDTs and local strains on the surface of specimens were measured by strain gauges. And axi-symmetrically elastoplastic FEM analyses was carried out for cylindrical specimens. Considering the influence of the restraint induced by the loading platen, in the case of H/D=1, the strain distribution on the side of a specimen is obviously affected by the condition of platen contact. Furthermore, it is clear that the larger H/D ratio becomes, the smaller the influence to the strain distribution is. For the smooth contact condition, the strain on the side is not influenced by the stiffness of the specimen, the shape and the scale effect, the strain distribution coincides with the nominal total strain. Whereas, in the case of rough contact condition, the strain distribution is remarkably affected. It is made clear that strain responses of hard rock specimens may more sensitive than these of soft rock specimens as a results of interaction between loading platens and specimen and the uniaxial strength of specimens may strongly depends on this interaction and stress-strain relation is affected by the contact condition.

  • PDF

Oxygen Permeation Properties of Tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) Membranes under Different Condition of Feed Side and Permeate Side (공급 측과 투과 측 조건에 따른 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) 관형 분리막의 산소투과 특성)

  • Kim, Jong-Pyo;Park, Jung-Hoon;Lee, Yong-Taek;Choi, Young-Jong
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.155-162
    • /
    • 2011
  • Dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) membranes were prepared by extrusion technique. The phase structure of the $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membranes was characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). Relative density of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ tubular membrane was 94.10%. Oxygen permeation was measured at difference operating condition of feed side and permeate side in the temperature range from 700 to $950^{\circ}C$. The oxygen permeation flux of dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane reached maximum 1.37 mL/$min{\cdot}cm^2$ at $900^{\circ}C$ exposed to ambient air (feed side) and vacuum pump (permeate side).

Structural Analysis of Built-in Side-by-Side Refrigerator with Ice Dispenser and Home Bar and Evaluation of Door Differences and Gasket Gap (얼음디스펜서와 홈바가 있는 빌트인 양문형 냉장고의 구조해석 및 도어 단차와 개스킷 간극의 평가)

  • Ryu, Si-Ung;Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.465-473
    • /
    • 2018
  • A cabinet-door integrated finite element model for a built-in side-by-side refrigerator with an ice dispenser and home bar was constructed, and its deformation was analyzed by ANSYS. As loads, the food load in the shelf and baskets, and thermal load occurring during the normal operation condition were considered. From results of the analyses, the door height difference (DHD) and door flatness difference (DFD) between the two doors, and the increase in the gap of the door gasket, which affects the sealing of cool air in the cabinet, were derived. As results of an evaluation of the differences, the DHD and DFD under the assembled condition satisfied the acceptance criteria of the manufacturer. The food and thermal loads increased the DHD and DFD due to thermal deformation, and the DFD increased significantly. In addition, the increase in the gap of door gasket located between the cabinet and doors was derived from the results of displacements under the food and thermal loads. The evaluation showed that the maximum increase in gap appeared at the left edge of the freezing compartment gasket, which satisfied the acceptance criteria of the manufacturer.

A survey about experience of combined medications of Korean herbal drugs and Western drugs with outpatients in oriental and western hospitals (한.양방 병원 외래환자의 한.양약 동시복용 경험 실태조사)

  • Oh, Moon-Su;Kang, Jae-Seung;Hwang, Young-Il;Jung, Hee-Jae;Kim, Yun-Kyung
    • Herbal Formula Science
    • /
    • v.18 no.2
    • /
    • pp.135-158
    • /
    • 2010
  • The purpose of this survey was to find out the actual condition and the problems of combined medications of patients who have general diseases, respiratory diseases. The objects of this survey were 1,769 outpatients who visited 8 Oriental hospitals and Seoul national university hospital respiratory clinics. SPSS program was used to analyze the survey data. The mean age of patients was lower in oriental hospital than in western hospital. The monthly family incomes were higher in oriental hospital patients than in western hospital patients. The condition of patients was better in oriental hospital than western hospital and self-assessed health status was more positive in oriental hospital patients than in western hospital patients. The percentage of having experienced of treated in oriental and western hospital at the same time was 21% in western hospital patients and 45% in oriental hospital patients. In patients with respiratory diseases, the percentage of having taken combined medications was 40.2% in oriental hospital and 13.7% in western hospital. In patients with non-respiratory diseases, the percentage of having taken combined medications was 27.4% in oriental hospital and 8.3% in western hospital. And in the patients with two different diseases, the percentage of having taken combined medications was 27.9% in oriental hospital and 6.3% in western hospital. The percentage of having experienced synergistic effects was 33.0% in western hospital and 56.3% in oriental hospital. The percentage of side effects was 12.6% in western hospital and 12.2% in oriental hospital. This survey was meaningful in that it reported the actual condition of combined medications of patients who have general diseases, respiratory diseases. For the deep study on synergistic and side effects of combined medications, it is necessary to collect many cases of synergistic and side effects by doctors in western and oriental hospitals.

Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition (난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.116-123
    • /
    • 2008
  • In order to study the heat transfer, effectiveness and pressure drop of an internal heat exchanger (IHX) for $CO_2$, heat pump under heating condition, the experiment and numerical analysis were performed. Four kinds of IHXs were used. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of IHX on the flow rate of refrigerant, the IHX length, the operating condition of a gas-cooler and an evaporator and the type of IHXs were investigated. With increasing the flow rate, the heat transfer rate increased about 25%. The heat transfer of the micro-channel tube was larger about 100% than that of the coaxial tube. With increasing the IHX length, the heat transfer rate decreased. The low-side pressure drop was larger compared with that of the high-side. And the pressure drop of the microchannel tube was larger about 100% than that of the coaxial tube. With increasing the high-side temperature and decreasing the low-side temperature, the heat transfer rate increased about 3%. From this study, we can see that new correlation on $CO_2$ heat transfer characteristics and tube type is necessary.

Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch (파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구)

  • Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

Experiments on Stability of Tetrapods on Rear Slope of Rubble Mound Structures under Wave Overtopping Condition (월파조건에서 경사제 항내측 사면에 거치된 테트라포드의 안정성 실험)

  • Kim, Young-Taek;Lee, Jong-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.6
    • /
    • pp.357-366
    • /
    • 2021
  • In this study, hydraulic model tests were performed to investigate the stability of armor units at harbor side slope for rubble mound structures. The Korean design standard for harbor and fishery port suggested the design figures that showed the ratio of the armor weight for each location of rubble mound structures and it could be known that the same weight ratio was needed to the sea side and harbor side (within 0.5H from the minimum design water level) slope of rubble mound structures. The super structures were commonly applied to the design process of rubble mound structures in Korea and the investigation of the effects of super structures would be needed. The stability number (Nod = 0.5) was applied (van der Meer, 1999) and it showed that the armor (tetrapod) weight ratio for harbor side slope of rubble mound structures needed 0.8 times of that for sea side slope.

Numerical Simulation on Seepage and Seismic Behaviors of Poorly-Compacted Raised Reservoir Levee (다짐시공이 불량한 증고 저수지 제체의 침투 및 동적거동 해석)

  • Lee, Chung-Won;Park, Sung-Yong;Oh, Hyeon-Mun;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.85-99
    • /
    • 2015
  • It is urgent to redevelop the superannuated reservoir levee through the levee raising for countermeasure to climate change and improvement of storage capacity of reservoir. However, low compaction degree of the raised reservoir levee owing to poor construction condition leads to degradation of the stability of the reservoir levee on seepage and earthquake. In this study, seepage and seismic behavior of raised reservoir levee with low compaction degree was evaluated through numerical simulation. From the simulated results, water level raising possibly induces crack and/or sinkhole on the surface of the poorly-compacted raised reservoir levee owing to the increase of the subsidences at the crown and the front side of that. In addition, relatively larger displacement and acceleration response at the front side of raised reservoir levee in seismic condition may degrade overall stability of reservoir levee. Therefore, reasonable construction management for the compaction of the raised reservoir levee is required for ensuring long-term stability on seepage and earthquake.