• 제목/요약/키워드: Side Walls

검색결과 299건 처리시간 0.024초

선택적 경사 노광과 후면 노광에 의한 3차원 구조물의 제작 (Fabrication of 3-D Structures by Inclined and Rear-side Exposures)

  • 이준섭;신현준;문성욱;송석호;김태엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.47-52
    • /
    • 2004
  • 3D microstructures with different side-wall angles and different scales are fabricated by both methods of inclined exposure and rear-side exposure at each of selected areas on a same substrate. Conventional methods of inclined exposure are used to make side-walls with a same inclined angle on one substrate and to get a scale error due to front-side exposure through thick photoresist layer, But, by using the proposed method, we are able to fabricate 3D microstructures on a same substrate with various side-wall angles and accurate dimensions as the original design. In the rear-side exposure, UV exposure light reflects from the chromium mask pattern after passing through the thick photoresist layer, resulting in fabrication of well-defined, inclined 3D structures inside the thick photoresist layer.

정사각형 계의 전도-복사열전달에서 정반사면의 영향 (Effects of a Specularly Reflecting Wall in an Infinite Square Duct on Conductive-Radiative Heat Transfer)

  • 변기홍;한동천
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1451-1458
    • /
    • 2001
  • The effects of a specularly reflecting surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The walls are opaque, and black or gray. The walls emit diffusely but reflect diffusely or speculary. Heat is transferred by the combined effect of conduction and radiation. The radiative heat transfer is analyzed using direct discrete-ordinates method. The parameters under study are conduction, to radiation parameter, optical depth, wall emissivity, and reflection characteristics. The specular reflection and diffuse reflection show sizeable differences when the conduction to radiation parameter is less than around 0.01. The differences appear only either on the side wall heat flux or on the medium temperature profiles for the range of this study. The differences on the side wall heat flux are observed for optical thickness less than around 0.1 However the differences on the medium temperate profiles are found for optical thickness greater than around 1. The difference increase with increasing reflectance. The specular reflection increases the well heat flux gradient along the side wall.

1차 단순 확산체를 적용한 교실음향설계 (The Application of 1-Dimensional Diffusers in Classroom Acoustics)

  • 최영지
    • 교육시설 논문지
    • /
    • 제18권5호
    • /
    • pp.3-11
    • /
    • 2011
  • In this study, the effect of treating 1-dimensional diffusers on the classroom acoustics was investigated to determine if the diffuser are beneficial for performing the preferred acoustical conditions for speech. A 1/10 scale model of a classroom was used to measure the acoustical parameters, T30, $C_{50}$, STI and SNR in that room. The room acoustical conditions were varied by treating diffusers either on the front or side walls of the classroom. When the diffusers were treated on the side walls around the student's areas, a shorter reverberation time at low frequencies was obtained and resulted in performing uniform reverberation times across the frequency bands. The $C_{50}$ values at mid- and high-frequencies were increased by treating the diffusers either on front or side wall surfaces. The highest STI and SNR values were obtained when the diffuser was treated on the front wall around the teacher's areas. It is found that diffusers are beneficial to increase the intelligibility of speech for the rear seats of the rooms.

  • PDF

사질토 지반에서 흙막이벽체-지하공간 연속 굴착에 따른 지반거동에 대한 실험적 연구 (Experimental study on the ground movement due to consecutive construction of retaining wall and underground space in cohesionless soil)

  • 박종덕;유정선;김도엽;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.267-281
    • /
    • 2015
  • 본 연구에서는 흙막이벽과 같은 수직굴착과 터널과 같은 지하공간의 연속적인 굴착에 따른 지반 거동과 토압 변화를 실험적으로 연구하였다. 굴착 단계별로 벽체 거동, 토압 변화, 그리고 지표 침하의 측정이 가능한 길이 160cm, 높이 120cm의 모형 토조를 제작하였다. 실험은 균일하게 조성된 사질토 지반에서 벽체에 임의의 변위를 가하고, 토압 변화와 지표 침하를 확인하는 방식으로 수행하였다. 모형실험은 흙막이벽과 지하공간의 연속적인 시공을 모사하기 위하여 흙막이벽 굴착을 모사하는 우측벽체 10개 및 지하공간 굴착을 모사하는 하부벽체 5개를 순서대로 거동시켜 모사하였다. 실험 결과, 벽체의 주동변위로 감소된 토압이 주변 벽체로 분담되는 아칭현상이 모든 벽체에서 발생함을 확인하였다. 연속되는 시공을 모사한 실험에서 phase마다 아칭현상을 확인할 수 있으나, 하부1단 벽체의 거동 시, 우측10단 벽체는 다른 경우와 달리 토압이 50%정도만 회복됨을 보였다.

평엔드밀링 공정에서 절삭속도 및 이송속도가 측벽의 축방향 형상에 미치는 영향 (Effects of Cutting Speed and Feed Rate on Axial Shape in Side Walls Generated by Flat End-milling Process)

  • 김강
    • 대한기계학회논문집A
    • /
    • 제41권5호
    • /
    • pp.391-399
    • /
    • 2017
  • 절삭속도 및 이송속도가 평엔드밀로 하향절삭 가공된 측벽 형상에 미치는 영향을 실험을 통하여 알아보고자 한다. 실험은 절삭속도 및 공구 직경, 절삭날 당 이송거리를 변수로 하여 수행하며, 실험 결과로서 배분력과 축방향 형상을 측정한다. 연구 결과, 이송속도를 절삭속도로 나눈 값에 비례하는 날 당 이송거리가 작을수록 축방향 형상정밀도가 높아지는 것이 확인되었다. 아울러, 축방향 형상은 서로 다른 기울기를 갖는 두 직선이 특이점에서 만나는 형태로 단순화 할 수 있다. 그러므로 운전 중 작업자에 의한 형상정밀도의 추정 및 날 당 이송거리 조정에 의한 개선이 용이할 것으로 판단된다.

Effect of Wall Thickness on Thermal Behaviors of RC Walls Under Fire Conditions

  • Kang, Jiyeon;Yoon, Hyunah;Kim, Woosuk;Kodur, Venkatesh;Shin, Yeongsoo;Kim, Heesun
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권sup3호
    • /
    • pp.19-31
    • /
    • 2016
  • The objective of this paper is to investigate the effect of thickness and moisture on temperature distributions of reinforced concrete walls under fire conditions. Toward this goal, the first three wall specimens having different thicknesses are heated for 2 h according to ISO standard heating curve and the temperature distribution through the wall thickness is measured. Since the thermal behavior of the tested walls is influenced by thickness, as well as moisture content, three additional walls are prepared and preheated to reduce moisture content and then tested under fire exposure. The experimental results clearly show the temperatures measured close to the fire exposed surface of the thickest wall with 250 mm thickness is the highest in the temperatures measured at the same location of the thinner wall with 150 mm thickness because of the moisture clog that is formed inside the wall with 250 mm of thickness. This prevents heat being transferred to the opposite side of the heated surface. This is also confirmed by the thermal behavior of the preheated walls, showing that the temperature is well distributed in the preheated walls as compared to that in non-preheated walls. Finite element models including moisture clog zone are generated to simulate fire tests with consideration of moisture clog effect. The temperature distributions of the models predicted from the transient heat analyses are compared with experimental results and show good agreements. In addition, parametric studies are performed with various moisture contents in order to investigate effect of moisture contents on the thermal behaviors of the concrete walls.

아치형 2연동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Two-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권2호
    • /
    • pp.142-147
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on the two-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated using the experimental data. The results obtained are as follows : 1. The variation of the wind force with wind directions on the side walls was the greatest at the upwind edge of the walls. 2. The maximum negative wind force along the length of the roof appeared at the upwind edge at the wind direction of 60$^{\circ}$. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and wind direction of 0$^{\circ}$ and 0.4 in the first house and 0.6 and 30$^{\circ}$ in the second house, respectively. 4. The mean negative wind force on the side walls of the first house at the wind direction of 0$^{\circ}$ was far greater than that of the second house, and the maximum negative wind force on the roof occurred at the wind direction of 30$^{\circ}$. 5. The maximum lift force appeared on the second house at the wind direction of 30$^{\circ}$, but the lift force on the first house was far greater than that on the second house at the wind direction of 0$^{\circ}$. 6. The parts to be considered for the local wind forces were the edges of the walls, and the edges of the x-direction and the width ratio, 0.4 of the y-direction in the roofs.

  • PDF

아치형 3연동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Three-span Arched House)

  • 이현우;이석건
    • 생물환경조절학회지
    • /
    • 제2권1호
    • /
    • pp.46-52
    • /
    • 1993
  • The wind pressure distributions were analyzed through the wind tunnel experiment to provide fundamental criteria for the structural design on the three-span arched house according to the wind directions. In order to investigate the wind force distribution, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated from the experimental data. The results obtained are as follows : 1. The variation of the wind force with the wind directions on the side walls was the greatest at the upwind edge of the walls. The change of pressure from the positive to the negative on the side walls occurred at the wind direction of 30$^{\circ}$ in the first house and 60$^{\circ}$ in the third house. 2. The maximum negative wind force along the length of the roof appeared at the length ratio of 0-0.2, when the wind directions were 90$^{\circ}$ in the first house, 60$^{\circ}$ in the second house and 30$^{\circ}$ in the third house. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and the wind direction of 0.4 and 0$^{\circ}$ in the first house, 0.4-0.6 and 30$^{\circ}$ in the second house and 0.6 and 30$^{\circ}$ in the third house, respectively. 4. The maximum mean positive and negative wind forces occurred at the wind direction of 60$^{\circ}$ and 30$^{\circ}$, respectively, on the side walls of the first house, and the maximum mean negative wind force on the roof occurred at the wind direction of 30$^{\circ}$ in third house. 5. The maximum drag and lift forces occurred at the wind direction of 30$^{\circ}$, and the maximum lift force appeared in the third house. 6. The parts to be considered for the local wind forces were the edges of the walls, the edges of the x-direction of the roofs, and the locations of the width ratio of 0.4 of the first and third house and the center of the width of the second house for the y-direction of the roofs.

  • PDF

주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls.)

  • 박의원
    • 대한치과보철학회지
    • /
    • 제8권1호
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

부채형 공간내의 자연대류에 관한 수치해석적 연구 (A Numerical Study of Natural Convection within a Trapezoidal Enclosure)

  • 배태열;배태석;권순석
    • 설비공학논문집
    • /
    • 제4권1호
    • /
    • pp.11-19
    • /
    • 1992
  • The natural convection heat transfer within a trapezoidal enclosure with parallel cylindrical top and bottom walls at different temperatures and two adiabatic side walls are studied. A finite-difference method has been used to solve the governing equations numerically. The range of parameters studied herein are Prandtl number 0.7, aspect ratio from 0.5 to 4.0, Rayleigh number from $10^3$ to $3{\times}10^4$, enclosure tilt angle from 22.5 to 157.5 degrees. Mean and local Nusselt numbers are presented for discussing heat transfer characteristics within the enclosure. The heat balances for the hot and cold walls are differed by less than 1% for converged solutions, so these results appear to be reasonable.

  • PDF