• 제목/요약/키워드: Side Pressing

검색결과 38건 처리시간 0.025초

Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구 (DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC)

  • 이시혁;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

Ketamine에 의한 선행 진통법이 자궁적출술 환자의 수술 후 통증에 미치는 효과 (The Effects of Ketamine Preemptive Analgesia on Postoperative Pain in Patients undergoing a Hystrectomy)

  • 김홍연;윤혜상
    • 대한간호학회지
    • /
    • 제36권1호
    • /
    • pp.114-126
    • /
    • 2006
  • Purpose: This study was performed to evaluate the pre-emptive analgesic effects of a small dose of intravenous ketamine on postoperative pain in patients undergoing a hysterectomy. Method: Sixty patients undergoing a hystrectomy under general anesthesia were randomly allocated to 2 groups. The experimental group(30 patients) received 0.3mg/kg of ketamine after induction of anesthesia, approximately 5 min prior to surgery, but the control group(30 patients)did not receive ketamine. Data was collected in a double-blind manner from April 1st, to October 30th, 2004. Postoperatively, the patients used a patient-controlled analgesia(PCA) pump. Blood pressure, pulse rate, pain, anxiety, count of times pressing the PCA button, administeration of additional analgesics and side effects of ketamine were measured at 1 hour, 3 hours, 6 hours and 24 hours after the operation. Result: There were no statistical differences in blood pressure, pulse rate, pain and anxiety between the experimental and control groups. There were statistical differences in blood pressure, pulse rate, pain and anxiety during the 24 hours postoperatively. In the experimental group, the number of times pressing the PCA button and administering additional analgesic drugs were significantly lower than those of the control group. Conclusion: A 0.3 mg/kg dose of ketamine given at approximately 5 min before surgery resulted in decreasing the number of times pressing the PCA and the administration of additional analgesics.

Morphological optimization of process parameters of randomly oriented carbon/carbon composite

  • Raunija, Thakur Sudesh Kumar;Manwatkar, Sushant Krunal;Sharma, Sharad Chandra;Verma, Anil
    • Carbon letters
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2014
  • A microstructure analysis is carried out to optimize the process parameters of a randomly oriented discrete length hybrid carbon fiber reinforced carbon matrix composite. The composite is fabricated by moulding of a slurry into a preform, followed by hot-pressing and carbonization. Heating rates of 0.1, 0.2, 0.3, 0.5, 1, and $3.3^{\circ}C/min$ and pressures of 5, 10, 15, and 20 MPa are applied during hot-pressing. Matrix precursor to reinforcement weight ratios of 70:30, 50:50, and 30:70 are also considered. A microstructure analysis of the carbon/carbon compacts is performed for each variant. Higher heating rates give bloated compacts whereas low heating rates give bloating-free, fine microstructure compacts. The compacts fabricated at higher pressure have displayed side oozing of molten pitch and discrete length carbon fibers. The microstructure of the compacts fabricated at low pressure shows a lack of densification. The compacts with low matrix precursor to reinforcement weight ratios have insufficient bonding agent to bind the reinforcement whereas the higher matrix precursor to reinforcement weight ratio results in a plaster-like structure. Based on the microstructure analysis, a heating rate of $0.2^{\circ}C/min$, pressure of 15 MPa, and a matrix precursor to reinforcement ratio of 50:50 are found to be optimum w.r.t attaining bloating-free densification and processing time.

리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화 (Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery)

  • 김종도;유승조;김장수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.623-628
    • /
    • 2006
  • Laser material processing is a very fast advancing technology for various industrial applications. because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment. battery case has changed over joint geometry from welding of side position to flat one. In the case of a electrolyte injection hole in order to seal it. welding is carried out after pressing Al ball. At this time. an eccentric degree. contact length and gap are worked as a major parameters. As improving the method of Al ball pressing. it was able to reduce an eccentricity. increase the contact length and decrease gap. As a results of a experiment. a sound weld bead shape and crack-free weld bead can be obtained.

리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화 (Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery)

  • 김종도;유승조
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.339-343
    • /
    • 2005
  • Laser material processing is a very fast growing technology for various industrial applications, because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment, battery case has changed over joint geometry from welding of side position to flat one. In case of a electrolyte injection hole in order to seal it, welding is carried out after pressing Al ball. At this time, an eccentric degree, contact length and gap are worked as a major parameters. As improving the method of Al ball pressing, it was able to reduce an eccentricity, increase the contact length and decrease gap. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained.

  • PDF

The New Generation of Hydraulic Presses-Progress in the Forming Process

  • Prommer, Eric
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1276-1277
    • /
    • 2006
  • The ever increasing requirements on today's compacts with regard to their geometry and precision call for flexible high-precision and most capable production systems. DORST Technologies has coped with these requirements by developing the new HP series for pressing forces between 1600 kN and 16000 kN and the new HS series for pressing forces between 150 kN and 1200 kN. These fully hydraulic presses featuring upper ram, lower ram, core rod, filler, up to 4 lower tool levels and up to 4 upper tool levels with closed-loop controlled movements. Thanks to latest servo technology and an electronic bus system it is possible to have all movements closed-loop controlled in the desired relation to each other. Thus, today's hydraulic presses provide high stroke rates, low energy consumption and a user-friendly interface. The input of data is carried out via clearly arranged screen masks on a touch-screen. The innovative DORST $IPG^{(R)}$ (Intelligent Program Generator) has been designed to support the set-up staff in preparing and optimizing the toolprogram. The combination of the machine type with the hydraulic unit determines the productivity in consideration of the specific application and the part to be pressed. Thanks to the closed-loop control circuits, DORST hydraulic automatic presses of the latest generation ensure unmatched precision and repeatability - and consequently process reliability - often without necessitating subsequent machining steps.

  • PDF

하지 석고붕대제거후 정상측과 석고붕대 적용측의 상하지의 둘레, 피부두겹두께 및 하지근력의 비교 (Comparison of the circumference, skinfold thickness and leg strength of normal limb with those of casted limb following removal of leg cast)

  • 최명애;박미정
    • 대한간호학회지
    • /
    • 제23권1호
    • /
    • pp.56-67
    • /
    • 1993
  • The purpose of this study was to compare the circumference and skinfold thickness of upper and lower limb and the leg strength of the casted limb with those of the normal limb after removal of a leg cast. The subjects for the study were orthopedic patients who had had long and short leg casts or splints due to tibial, fibulal, metatarsal, calcaneus fracture or ankle sprains. The subjects were divided into two groups, those who had the cast on for less than 40 days and those for over 41 days. Circumference and skinfold thickness of the upper and lower limb on the side on which the cast was ap-plied were compared with those of the contralateral side after removal of the cast. Circumference and skinfold thickness of the upper and lower limb, and leg strength for those in a cast for under 40 days were compared with those of over 41 days for both the side to which cast was applied and the contralateral side. Measurements were made after removal of the cast. Skinfold thickness was measured by fat caliper, circumference was measured by tape and lower extremity strength was determined with flat foot pressing on an electronic digital health meter in the sitting position. The results can be summarized as follows : 1. The circumference of the upper and lower leg on the side on which the cast was applied, when measured after the cast was removed, were significantly less than those of the normal side, 93.88%, 93.11% each. 2. Skinfold thickness of the quadriceps and gastrocnemius on the side on which the cast was applied were significantly less than those of the normal side when measured after removal of the cast, 85.98%, 82.85% respectively. 3. Leg strength on the side where the cast was applied was significantly 1ss than that on the normal side, 60.20%. 4. There was no difference in the circumference of upper and lower limbs, skinfold thickness or leg strength on the side where the cast was applied between the group which had the cast applied for under 40 days and the group that had it applied for over 41 days. 5. The circumference of the upper arm and lower leg on the normal side for the group that had the cast applied for over 41 days was significantly greater than the group that had the cast application for under 40 days. T ere was no difference between the two groups in the circumference of the forearm and upper leg, skinfold thickness and leg strength in the normal side. From these results, it may be concluded that muscle atrophy was apparent in the casted limb compared to the normal limb, and the circumference of the upper arm and lower leg, and leg strength on the normal side increased after removal of the cast in the group which had the cast on for more than 41 days.

  • PDF

사물제통탕(四物除痛湯)이 Taxol 처리 및 좌골신경 압좌 손상 후 신경조직 변화에 미치는 영향 (Effects on Response of Nervous Tissue to Samuljetong-tang after Damaged by Taxol Treatment or Sciatic Nerve Injury)

  • 윤성식;김철중;조충식
    • 대한한방내과학회지
    • /
    • 제33권2호
    • /
    • pp.126-144
    • /
    • 2012
  • Background : Peripheral nerves more rapidly recover than central nerves. However, it has been known that the degree of reaction of axons of peripheral nerves is affected by distinctive characteristics of axons and environmental factors near the axons. Taxol is a widely used medicine as for ovarian, breast, lung and gastric cancer. However it causes patients difficulties under treatment due to its toxic and side effects, which include persistent pain. Objectives : This study reviewed how SJT extract in vitro and in vivo affects nerve tissues of a sciatic nerve damaged by Taxol. It also studied how SJT extract in vivo affects axons of the sciatic nerve after the sciatic nerve was damaged by pressing. Methods : After vehicle, Taxol, and Taxol plus SJT were treated respectively for tissue of the sciatic nerve in vitro and then tissues were observed using Neurofilament 200, Hoechst, ${\beta}$-tubulin, $S100{\beta}$, caspase-3 and anti-cdc2. SJT was also oral medicated by injecting Taxol into the sciatic nerve of in vivo rats. Tissues of the sciatic nerve and axons of DRG sensory nerves were then observed using Neurofilament 200, Hoechst, ${\beta}$-tubulin, $S100{\beta}$, caspase-3 and p-Erk1/2. After inflicting pressing damage to the sciatic nerve of in vivo rats, tissues of the sciatic nerve and DRG sensory nerve were observed using Neurofilament 200, Hoechst, $S100{\beta}$, caspase-3, anti-cdc2, phospho-vimentin, ${\beta}1$-integrin, Dil reverse tracking and p-Erk1/2. Results : The group of in vitro Taxol plus SJT treatment had meaningful effects after sciatic nerve tissue was damaged by Taxol. The group of in vivo SJT treatment had effects of regenerating Schwann cells and axons which were damaged by Taxol treatment. The group of in vivo SJT had effects of regenerating axons in damaged areas after the sciatic nerve was damaged by pressing, and also had variations of distribution in Schwann cells at DRG sensory nerves and axons. Conclusions : This study confirmed that SJT treatment is effective for growth of axons in the sciatic nerve tissues and improvement of Schwann cells after axons of the sciatic nerve tissues was damaged. After tissues of sciatic nerve was damaged by pressing in vivo, SJT treatment had effects on promoting regeneration of axon in the damaged area and reactional capabilities in axons of DRG sensory nerves.

요추간판탈출증(腰推間板脫出症)에 상용(常用)되는 중국추나(中國推拿) 기법(技法)에 관(關)한 연구(硏究) (Investigation on Common-Using Technique of Chinese Chuna Manipulations for Herniated Nucleus Pulposus)

  • 한무규;허수영;최진만
    • 대한추나의학회지
    • /
    • 제1권1호
    • /
    • pp.103-117
    • /
    • 2000
  • The manipulations are the main therapheutic procedure of Chuna. Manipulation is the essential procedure of Chuna theraphy. On the basis of touch parts and motion changes, each elementary manipulation is divided into Stimulating Manipulations (reflexional manipulations) and Mobilizing Manipulations. Objectives: This study were advanced so as to know Chinese Chuna Manipulations especially on Herniated Nucleus Pulposus. Methods We Investigated Chinese medicine paper about Chinese Chuna Manipulations on Herniated Nucleus Pulposus between 1996 and 1999. Results. Chinese Chuna theraphy, Pressing Manipulations and Thrusting-Wrenching Manipulations are mostly used on Herniated Nucleus Pulposus, and Chinese Chuna theraphy carrys out Traction, Injection. Chinese medicine. Acupuncture side by side. Conclusions: Chinese Chuna theraphy uses not only Mobilizing Manipulations, but also Stimulating Manipulations whereas Korean Chuna theraphy chiefly uses Mobilizing Manipulations.

  • PDF

열간 조압연 공정에서 슬래브 측면부의 소성변형거동 예측 (Prediction of Plastic Deformation Behavior of the Side Surface of Slab during Hot Rough Rolling)

  • 정재환;이경훈;이선봉;이인규;이상호;김형진;이계영;김병민
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.425-430
    • /
    • 2014
  • The aim of the current study was to predict the plastic deformation behavior of a heated slab during hot rough rolling. FE-simulations were performed to investigate the metal flow and to locate the position of surface material from the slab through the rough rolling and onto the strip, using a material point tracking technique. In addition, experimental hot rolling trials were conducted where artificial defects were impressed onto a heated slab in order to validate the FE-simulation results. The simulated results show the same tendency of deformation behavior as the experimental measurements. The movement of slab defects from the side surface towards the strip center is directly linked to the extent of lateral spread during the rolling.