• Title/Summary/Keyword: Shut Down system

Search Result 138, Processing Time 0.026 seconds

Development of Heal Time Lightning Information System (실시간 낙뢰화면 표시프로그램 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.175-177
    • /
    • 2003
  • Because the overhead transmission lines arc exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Study of Lay-out Design Concept for Liquid Rocket Engine System (액체로켓엔진 시스템 Lay-out 설계 개념 연구)

  • Chung, Yong-hyun;Lee, Eun-Seok
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.4
    • /
    • pp.42-45
    • /
    • 2007
  • The process of Lay-out design and assembly for liquid rocket engine was presented and the Lay-out design for main components of liquid Rocket engine system was studied. Vertical direction is recommended in the case of turbopump's arrangement. If the length of pipe between gas-generator with turbopump's turbine is shorter, gas-generator is stable. The arrangements of main valves are recommended as near disposition to combustion chamber, because shut-down process time is shorter. Interference with launch vehicle and structural strength considering gimbal actuator's force and control performance is considered in the case of gimbal actuator's supporter design.

  • PDF

Analysis of LPATS-III Error Level and the lightning characteristics in KOREA (LPATS-III의 오차검토 및 한반도 낙뢰발생빈도 분석결과)

  • Woo, J.W.;Shim, E.B.;Kwon, D.J.;Choi, Y.M.;Lee, S.J.;Kim, K.W.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1772-1774
    • /
    • 2002
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. To study the basic research of the lightning parameters for power system operation, LPATS-III (Lightning Positioning and Tracking System) has been introduced since 1995 in Korea. This paper describes the inspection result about location information error and the statistical distribution of lightning current.

  • PDF

A Study on the Stability of Control for Nonlinear Saturated Systems (비선형 포화시스템 제어에 관한 안정성 연구)

  • 정상화;오용훈;류신호;김상석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.208-208
    • /
    • 2000
  • In realistic control systems, the nonlinear salutation attributes of the control actuator due to physical limitations should be taken into account. This nonlinear saturation of actuators may cause not only deterioration of the control performance but also a large overshoot during start-up and shut-down. As the overshoot increases, the system may become oscillatory unstable. In this paper, the supervisor implementation which guarantees good performance lot saturation operation and prevents reset wind-up is presented. Moreover, the sufficient conditions of the stability for saturated systems using supervisory control with a dynamic controller are provided in the discrete-time domain. A numerical example is illustrated to depict the efficiency of supervisory control for a typical saturated production-distribution system controlled by a discrete-time dynamic controller and to validate basic results by simulation.

  • PDF

A Study on the Performance and Safety Evaluation for Residential Fuel Cell System under the Abnormal Condition (이상조건하에서 가정용 연료전지 시스템의 성능 및 안전성 평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.10-13
    • /
    • 2008
  • Fuel cell systems have witnessed remarkable development in recent years as they offer a clean and efficient alternative for power generation. Testing was conducted to determine the safety performance of a residential fuel cell system when subjected to abnormal operation condition, especially for voltage sag and fuel cut. In case of voltage sag to 198V, its arriving time at rated power had shown a slight lag but there wasn't any noticeable change when operating it between rated voltage(220V) and 10% voltage sag(198V). In case of fuel cut, it also showed stable shut-down characteristics. The test results are being used to develop a new safety evaluation for residential fuel cell system.

  • PDF

Experimental Test Results of Nine Scheduling Operational Modes of PV and Battery Hybrid System for the Development of Automatic Control Algorithm for Continual Operation without being shut-downed (태양광 배터리 Hybrid 전력공급시스템 9가지 운전 모드 시험결과 및 무고장 연속 운전을 위한 자동제어 알고리즘 개발)

  • Song, Taek Ho;Yang, Seung Kwon;Kim, Minjeong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • K-BEMS System was introduced to reduce peak load and to save total energy of the 200 buildings that KEPCO headquarter and branch offices use. And K-BEMS system is composed of PV, battery, and hybrid PCS. KEPCO research institute has carried out this K-BEMS research project for 3 years since January 2016. In this paper, the results of the project are shown. 9 modes of test results of K-BEMS system and are operational problems were analyzed. And measures to cure the trouble are also suggested. Batteries are operated more than 20% of SOC, and less than 20% of SOC battery protection switches are automatically shutting down the system and the system no longer respond to EMS, ending the supply of PV, and so therefore to continue the PV power supply it was turn out to be necessary that the EMS should automatically change its policy to change PV only supply mode automatically when the Battery Switch automatically operated. To operate the system continuously and automatically, it is necessary to modify the minimum operational SOC value, and in addition to that the EMS computer must remember the last shut-down SOC and Voltage which interrupted the system and add some margin to reflect the measurement error in the system.

Modeling of Liquid Rocket Engine Components Dynamics at Transient Operation (액체로켓엔진 천이작동 예측을 위한 구성품 동특성 모델링)

  • Kim, Hyung-Min;Lee, Kuk-Jin;Yoon, Woong-Sup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.35-44
    • /
    • 2011
  • Mathematical modelling for liquid rocket engine(LRE) main components were conducted to predict the dynamic characteristics when the LRE operates at the transient condition, which include engine start up, shut down, or thrust control. Propellant feeding system is composed of fuel and oxidizer feeding components except for regenerative cooling channel for the fuel circuit. Components modeling of pump, pipe, orifice, control valve, regenerative cooling channel and injector was serially made. Hydraulic tests of scale down component were made in order to validate modelling components. The mathematical models of engine components were integrated into LRE transient simulation program in concomitant with experimental validation.

A Study on Abnormal Noise Reduction of Scroll Compressor (Scroll Compressor의 이상 소음 저감에 관한 연구)

  • Ahn, B.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.28-35
    • /
    • 1999
  • An application of scroll compressor to the residential air conditioning and heat pump markets has generated many reliability problem, especially abnormal noise. Most of these noise problems is due to the check valve and compliance between FS(Fixed Scroll) and OS(Orbiting Scroll). FS and OS are the main parts of scroll compressor and are the main pumping part. But check valve has the role of protection of reverse rotation of OS when power is off. Check valve have several noise problems. Among them, shut down noise and valve movement noise is more than severe than any other problem. In this paper covers with these two noise problem.

  • PDF

The Inverter Control Method Using The Voltage Sag Compensation algorithm (순간전압강하 보상 알고리즘을 이용한 인버터 제어에 관한 연구)

  • Yun, Hong-Min;Bae, Jin-Yong;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.62-67
    • /
    • 2012
  • In this paper general purpose voltage source inverter drives are equipped with an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag control algorithm, experimental results are presented.

Analysis of the lightning characteristics by the LPATS in KOREA (낙뢰위치 표정시스템(LPATS)에 의한 2004넌 한반도 낙뢰통계 분석결과)

  • Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Kang, Y.W.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.606-608
    • /
    • 2005
  • As the overhead transmission lines are exposed to the outdoor weather, the causes of the transmission lines faults are from natural conditions, and among these faults, the outage rate due to lightning is more than 60%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF