• Title/Summary/Keyword: Shunt survival

Search Result 26, Processing Time 0.037 seconds

Clinical Outcome of Endoscopic Procedure in Patients with Shunt Malfunction

  • Kyung Hyun Kim;Youngbo Shim;Ji Yeoun Lee;Ji Hoon Phi;Eun Jung Koh;Seung-Ki Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.162-171
    • /
    • 2023
  • Objective : The goal of this study was to analyze the clinical outcomes of endoscopic third ventriculostomy (ETV) and endoscopic septostomy when shunt malfunction occurs in a patient who has previously undergone placement of a ventriculoperitoneal shunt. Methods : From 2001 to 2020 at Seoul National University Children's Hospital, patients who underwent ETV or endoscopic septostomy for shunt malfunction were retrospectively analyzed. Initial diagnosis (etiology of hydrocephalus), age at first shunt insertion, age at endoscopic procedure, magnetic resonance or computed tomography image, subsequent shunting data, and follow-up period were included. Results : Thirty-six patients were included in this retrospective study. Twenty-nine patients, 18 males and 11 females, with shunt malfunction underwent ETV. At the time of shunting, the age ranged from 1 day to 15.4 years (mean, 2.4 years). The mean age at the time of ETV was 13.1 years (range, 0.7 to 29.6 years). Nineteen patients remained shunt revision free. The 5-year shunt revision-free survival rate was 69% (95% confidence interval [CI], 0.54-0.88). Seven patients, three males and four females, with shunt malfunction underwent endoscopic septostomy. At the time of shunting, the age ranged from 0.2 to 12 years (mean, 3.9 years). The mean age at the time of endoscopic septostomy was 11.9 years (range, 0.5 to 29.5 years). Four patients remained free of shunt revision or addition. The 5-year shunt revision-free survival rate was 57% (95% CI, 0.3-1.0). There were no complications associated with the endoscopic procedures. Conclusion : The results of our study demonstrate that ETV or endoscopic septostomy can be effective and safe in patients with shunt malfunction.

A Comparative Result of Ventriculoperitoneal Shunt, Focusing Mainly on Gravity-Assisted Valve and Programmable Valve

  • Lee, Won-Chul;Seo, Dae-Hee;Choe, II-Seung;Park, Sung-Choon;Ha, Young-Soo;Lee, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.251-258
    • /
    • 2010
  • Objective : Despite rapid evolution of shunt devices, the complication rates remain high. The most common causes are turning from obstruction, infection, and overdrainage into mainly underdrainage. We investigated the incidence of complications in a consecutive series of hydrocephalic patients. Methods : From January 2002 to December 2009, 111 patients underwent ventriculoperitoneal (VP) shunting at our hospital. We documented shunt failures and complications according to valve type, primary disease, and number of revisions. Results : Overall shunt survival time was 268 weeks. Mean survival time of gravity-assisted valve (GAV) was 222 weeks versus 286 weeks for other shunts. Survival time of programmable valves (264 weeks) was longer than that of pressure-controlled valves (186 weeks). The most common cause for shunt revision was underdrainage (13 valves). The revision rate due to underdrainage in patients with GAV (7 of 10 patients) was higher than that for other valve types. Of 7 patients requiring revision for GAV underdrainage, 6 patients were bedridden. The overall infection rate was 3.6%, which was lower than reported series. Seven patients demonstrating overdrainage had cranial defects when operations were performed (41%), and overdrainage was improved in 5 patients after cranioplasty. Conclusion : Although none of the differences was statistically significant, some of the observations were especially notable. If a candidate for VP shunting is bedridden, GAV may not be indicated because it could lead to underdrainage. Careful procedure and perioperative management can reduce infection rate. Cranioplasty performed prior to VP shunting may be beneficial.

The Contributory Factors of CSF Shunt Failure (뇌실 복강간 단락 부전의 기여인자)

  • Kim, Young Don;Hwang, Sung Kyoo;Hwang, Jeong Hyun;Sung, Joo Kyung;Hamm, In Suk;Park, Yeun Mook;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.79-84
    • /
    • 2001
  • To investigate contributory factors of CSF shunt failure, 237 patients, who underwent shunt placement from January 1995 to December 1998 at our hospital, were reviewed retrospectively. The causes of the hydrocephalus were tumor, hemorrhage, infection, congenital anomaly, normal pressure hydrocephalus, trauma and others. One hundred nine revisions of CSF shunting were done during follow up periods. The causes of shunt revisions were mechanical obstruction, malposition, infection and others. The contributory factors of CSF shunt failure and shunt survival rate were analyzed using SPSS. The shunt survival rate at 1, 2 and 3 years after procedure was 77.1%, 75.4%, 74.1% respectively. In the young age group below 10 years old, postinfectous hydrocephalus was the most common high risk factor for shunt revision. In conclusion, the most shunt failures developed in the first year after surgery and the age and causes of the hydrocephalus were major determinant factors of shunt revision.

  • PDF

Optimization of the Anastomosis Angle and Diameter with the Systemic- To-Pulmonary Artery Shunt (대동맥-폐동맥 연결관의 접합각도와 직경의 최적화)

  • Kim, Sung-Min;Park, Sung-Yun;Jun, Jae-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.123-130
    • /
    • 2007
  • Hypoplastic left heart syndrome is currently the most lethal cardiac malformation of the newborn infant. Survival following a Norwood operation depends on the balance between systemic and pulmonary blood flow, which is highly dependent on the fluid dynamics through the interposition shunt between the two circulations. The purpose of this study is an optimization of the systemic-to-pulmonary artery shunt. In this study, We used computational fluid dynamic(CFD) models to determine the velocity profile in a systemic-to-pulmonary artery shunt and suggested a simplified method of calculating the blood flow in the shunt based on Ultrasound systems. We analyzed the flow characteristic variations and oscillatory shear index(OSI) due to the anastomosis angle and shunt diameter changing. Four different CFD models were constructed with the shunt sizes ranging from 3 to 3.5mm. The angle between the brachiocephalic trunk(BCT) and the shunt were $30^{\circ}$ and $45^{\circ}$, respectively. When the diameter is 3.0 mm, the oscillatory shear index decreased by 1.2% at $30^{\circ}$ as opposed to at $45^{\circ}$. When the diameter is 3.5 mm, it increased by 18% more at $30^{\circ}$ as opposed to at $45^{\circ}$. When the joint angle is $30^{\circ}$ and the diameter is 3.0 mm, the oscillatory shear index decreased by 4.1% in comparison with the 3.5 mm diameter. When the angle is $45^{\circ}$ and the diameter is 3.0 mm, the index increased by 14.6% in comparison with the 3.5 mm diameter.

Clinical Application and its Result of Modified Blalock-Taussig Shunt Using Polytetrafluoroethylene in Congenital Cyanotic Heart Disease (청색심기형환자에서 PTFE 인조혈관을 이용한 쇄골하-폐동맥 단락술의 임상적 적용과 그 결과)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 1988
  • This report provides follow-up data on 116 patients with congenital cyanotic heart disease, aging 1 month to 13 years [median: 1.8 years], who underwent the modified Blalock-Taussig shunt using polytetrafluoroethylene graft at Seoul National University Hospital between September, 1984 and June, 1987. Among 116 patients complete follow-up studies were done on 95 patients. The mean preoperative arterial oxygen tension was 36 torr. Thirty-Six patients [38%] underwent operation in infancy. Conduit diameters included 4mm [15 cases], 5mm [47 cases], and 6mm [33 cases] sizes. The mean postoperative arterial oxygen tension was 52 torr [P<0.001]. The effectiveness of shunts was evaluated clinically and by shunt murmur, echocardiography and cardiac catheterization with angiography 1 to 31 months after operation. The incidence of shunt occlusion was 9.5% and the mortality was 14.8%. The actuarial patency rate was 83.1 * 6.4% and the actuarial survival rate was 82.5 * 4.5% at 30 months` follow-up for all patients. The effectiveness of the 4mm diameter conduit may be limited. Blalock-Taussig procedure is an effective alternative to the classic B-T shunt in congenital cyanotic heart disease.

  • PDF

Balloon-Occluded Retrograde Transvenous Obliteration versus Transjugular Intrahepatic Portosystemic Shunt for the Management of Gastric Variceal Bleeding

  • Gimm, Geunwu;Chang, Young;Kim, Hyo-Cheol;Shin, Aesun;Cho, Eun Ju;Lee, Jeong-Hoon;Yu, Su Jong;Yoon, Jung-Hwan;Kim, Yoon Jun
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.704-713
    • /
    • 2018
  • Background/Aims: Gastric varices (GVs) are a major cause of upper gastrointestinal bleeding in patients with liver cirrhosis. The current treatments of choice are balloon-occluded retrograde transvenous obliteration (BRTO) and the placement of a transjugular intrahepatic portosystemic shunt (TIPS). We aimed to compare the efficacy and outcomes of these two methods for the management of GV bleeding. Methods: This retrospective study included consecutive patients who received BRTO (n=157) or TIPS (n=19) to control GV bleeding from January 2005 to December 2014 at a single tertiary hospital in Korea. The overall survival (OS), immediate bleeding control rate, rebleeding rate and complication rate were compared between patients in the BRTO and TIPS groups. Results: Patients in the BRTO group showed higher immediate bleeding control rates (p=0.059, odds ratio [OR]=4.72) and lower cumulative rebleeding rates (logrank p=0.060) than those in the TIPS group, although the difference failed to reach statistical significance. There were no significant differences in the rates of complications, including pleural effusion, aggravation of esophageal varices, portal hypertensive gastropathy, and portosystemic encephalopathy, although the rate of the progression of ascites was significantly higher in the BRTO group (p=0.02, OR=7.93). After adjusting for several confounding factors using a multivariate Cox analysis, the BRTO group had a significantly longer OS (adjusted hazard ratio [aHR]=0.44, p=0.01) and a longer rebleeding-free survival (aHR=0.34, p=0.001) than the TIPS group. Conclusions: BRTO provides better bleeding control, rebleeding-free survival, and OS than TIPS for patients with GV bleeding.

Acute Pulmonary Edema and Congestion in the Right Upper Lobe after Waterston-Cooley Shunt for Tetralogy of Fallot: A Case Report (활로4증후에서 Waterston-Cooley 문합수술후에 발생한 우상엽 폐수종: 1례 보고)

  • 송충웅
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.113-117
    • /
    • 1977
  • The tetralogy of Fallot is one of the most frequent and serious congenital cardiac malformation accompanied cyanosis. For relief of cyanosis, the Waterston operation is a successful, palliative procedure in infant & young child under age of five with obstructive lesions of the right: side of the heart who require a systemic-pulmonary arterial shunt for survival. A patient, aged 3 and weighing 13 kg., who had been cyanotic since one month after birth,. was admitted to the University of Severance Hospital under a diagnosis of tetralogy of Fallot, The side to side anastomosis between the right pulmonary artery & the ascending aorta was performed in March 1976. The anastomotic channel was made only 4 ram. in diameter, thereafter massive unilateral pulmonary congestion on the side of the anastomosis developed shortly after operation. And the. patient died of congestive heart failure within a hour. And so the purpose of this report is describe the immediate & late effect of systemic-pulmonary shunt for T.O.F. with review of literatures.

  • PDF

Outcome of Staged Repair of Tetralogy of Fallot with Pulmonary Atresia and a Ductus-dependent Pulmonary Circulation: Should Primary Repair Be Considered?

  • Kim, Hyung-Tae;Sung, Si-Chan;Chang, Yun-Hee;Jung, Won-Kil;Lee, Hyoung-Doo;Park, Ji-Ae;Huh, Up
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.392-398
    • /
    • 2011
  • Background: The tetralogy of Fallot (TOF) with pulmonary atresia (PA) and a ductus-dependent pulmonary circulation (no major aorto-pulmonary collateral arteries (MAPCAs)) has been treated with staged repair or primary repair depending on the preference of surgeons or institutions. We evaluated the 19-year outcome of staged repair for this anomaly to find out whether our surgical strategy should be changed. Materials and Methods: Forty-four patients with TOF/PA with patent ductus arteriosus (PDA) who underwent staged repair from June 1991 to October 2010 were included in this retrospective study. The patients with MAPCAs were excluded. The average age at the first palliative shunt surgery was $40.8{\pm}67.5$ days (range: 0~332 days). Thirty-one patients (31/44, 70%) were neonates. The average weight was $3.5{\pm}1.6$ kg (range: 1.6~8.7 kg). A modified Blalock-Taussig (BT) shunt was performed in 38 patients, classic BT shunt in 4 patients, and central shunt in 2 patients. Six patients required concomitant procedures: pulmonary artery angioplasty was performed in 4 patients, pulmonary artery reconstruction in one patient, and re-implantation of the left pulmonary artery to the main pulmonary artery in one patient. Four patients required a second shunt operation before the definitive repair was performed. Thirty-three patients underwent definitive repair at $24.2{\pm}13.3$ months (range: 7.3~68 months) after the first palliative operation. The average age at the time of definitive repair was $25.4{\pm}13.5$ months (range: 7.6~68.6 months) and their average weight was $11.0{\pm}2.1$ kg. For definitive repair, 3 types of right ventricular outflow procedures were used: extra-cardiac conduit was performed in 30 patients, trans-annular patch in 2 patients, and REV operation in 1 patient. One patient was lost to follow-up after hospital discharge. The mean follow-up duration for the rest of the patients was $72{\pm}37$ months (range: 4~160 months). Results: Ten patients (10/44, 22.7%) died before the definitive repair was performed. Four of them died during hospitalization after the shunt operation. Six deaths were thought to be shunt-related. The average time of shunt-related deaths after shunt procedures was 8.7 months (range: 2 days~25.3 months). There was no operative mortality after the definitive repair, but one patient died from dilated cardiomyopathy caused by myocarditis 8 years and 3 months after the definitive repair. Five-year and 10-year survival rates after the first palliative operation were 76.8% and 69.1%, respectively. Conclusion: There was a high overall mortality rate in staged repair for the patients with TOF/PA with PDA. Majority of deaths occurred before the definitive repair was performed. Therefore, primary repair or early second stage definitive repair should be considered to enhance the survival rate for patients with TOF/PA with PDA.

The effect of Radiation Therapy on the Use of Proven Prosthesis in Laryngectomees (방사선 치료 환자에서의 Provox 사용)

  • 김광현;성명훈;이창호;전상준;고태용
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.177-181
    • /
    • 1998
  • Provox is now widely used for voice rehabilitation for total laryngectomized patient because of its low airway resistance and easiness for phonation. This study was designed to reveal the influence of radiation therapy on Proven complications. Forty-four patients who underwent total laryngectomy were grouped into group A (no radiation), group B(radiation and then Provox insertion), group C(Proven insertion and then radiation). Provox complications were leakage, granulation tissue formation, malfunction and infection. The average survival time of Provox was longer in group C (9.2 me) than group A(8.6 m) or group B (7.3 me), but no statistical significance was found. The first time of Provox change was 10.2, 8.6 and 9.7 months respectively. The incidence of complication was not significantly different among groups. The cases of Provox remeval due to shunt failure were 5, 4 and 2 respectively. Even though a significant statistically difference was not found partialy due to the small numbers of patients, a special caution should be exercised in inserting Provox to prevent a serious complication for the patients who had a history of previous radiation.

  • PDF

ClC Chloride Channels in Gram-Negative Bacteria and Its Role in the Acid Resistance Systems

  • Minjeong Kim;Nakjun Choi;Eunna Choi;Eun-Jin Lee
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.7
    • /
    • pp.857-863
    • /
    • 2023
  • Pathogenic bacteria that colonize the human intestinal tract have evolved strategies to overcome acidic conditions when they pass through the gastrointestinal tract. Amino acid-mediated acid resistance systems are effective survival strategies in a stomach that is full of amino acid substrate. The amino acid antiporter, amino acid decarboxylase, and ClC chloride antiporter are all engaged in these systems, and each one plays a role in protecting against or adapting to the acidic environment. The ClC chloride antiporter, a member of the ClC channel family, eliminates negatively charged intracellular chloride ions to avoid inner membrane hyperpolarization as an electrical shunt of the acid resistance system. In this review, we will discuss the structure and function of the prokaryotic ClC chloride antiporter of amino acid-mediated acid resistance system.