• Title/Summary/Keyword: Shunt

Search Result 1,326, Processing Time 0.03 seconds

Carotid Endarterectomy for Common Carotid Artery Stenosis Using Internal Shunt -A Report of Case- (Internal shunt를 이용한 총경동맥협착 수술치험 -1례 보고-)

  • 조용길
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.324-327
    • /
    • 1995
  • Extracranial carotid artery disease is rare and closely related to cardiovascular morbidity and mortality.We experienced one case of surgical treatment of left common carotid artery stenosis using internal shunt.The patient was 54-year-old female presented as headache and dizziness for about 2 years.On Doppler ultrasound, an atheromatous plaque was noted along the posteromedial wall of left common carotid artery resulting in luminal narrowing in about 75s of cross section area.The atheroma was resected through carotid endarterectomy, measured about 5.2cm in length. Postoperative course was uneventful and she was discharged in good condition.

  • PDF

Long-term Shunt VAr Planning using Optimal Power Flour (OPF를 이용한 중장기 전력계통 조상설비 계획수립)

  • Ryu, Heon-Su;Bae, Ju-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.301-303
    • /
    • 2005
  • This paper presents long-term shunt capacitor planning using optimal power flow. OPF allows the planning engineer to find feasible solution with minimal amount of engineering time. We used OPF for Shunt capacitor planning to get an optimal solution. The result of OPF is compared to the analysis by the conventional loadflow method and it is proved that OPF gives more cheaper and better planning solution. With the result, we analyzed the operational perspective for the reactive power supply and demand.

  • PDF

Malignant Ascites after Subduroperitoneal Shunt in a Patient with Leptomeningeal Metastasis

  • Lee, Min-Ho;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.385-387
    • /
    • 2011
  • Leptomeningeal metastasis is a devastating complication of advanced stage cancer. It is frequently accompanied by hydrocephalus and intracranial hypertension that must be treated by ventriculoperitoneal shunts. However, there are actual risks of peritoneal seeding or accumulation of malignant ascites after the cerebrospinal fluid diversion procedure, though it has not been reported. Here, we present the case of a patient with non-small cell lung cancer with leptomeningeal metastasis in whom malignant ascites developed after a subduroperitoneal shunt.

Increase of voltage ratings in the superconducting fault current limiter using thin films by shunt resistors (션트저항을 통한 박막형 초전도 한류기의 전압등급 증대)

  • 최효상;김혜림;황시돌;박권배;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.176-177
    • /
    • 2001
  • Three nearly identical superconducting fault current limiters (SFCLs) were connected in series to increase the voltage ratings. A slight difference in the quench starting point of individual SFCL units produced significantly imbalanced power distribution when connected in series. The imbalance was successfully removed by connecting a shunt resistor to one SFCL in parallel. 1.2 kV SFCL was designed with five current limiting elements and two or three shunt resistors.

  • PDF

Power Flow Control of Thyristor Controlled Shunt Compensator (싸이리스터 제어 병렬 보상기에 의한 전력 제어 연구)

  • 정교범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.680-683
    • /
    • 1999
  • A thyristor controlled shunt compensator, which is installed in the middle of the transmission line is adopted for controlling real power flow in a simple power transmission system. By means on the Fourier series representation of the thyristor switching action and the system parameters, the thyristor current equations are derived, which transmit the required real power of the simple power transmission system and inform the thyristor firing angle, the thyristor conduction angle, the power flows and the harmonic characteristics EMTP simulations at the various operating points show the dynamic characteristics of the thyristor controlled shunt compensator and correspond to the results calculated with the Fourier series representation.

  • PDF

8㎓ SPST SWITCH USING SERIES-SHUNT DIODE (SERIES-SHUNT 다이오드를 이용한 8㎓ SPST SWITCH)

  • 권우성;임준열;임정현;김범만
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.352-355
    • /
    • 2002
  • 본 논문에서는 series-shunt type의 PIN diode를 사용하여 8 ㎓ (7.7㎓ - 8.3㎓) 에서 사용 가능한 switch를 설계 제작하였다 스위치의 중요한 사양인 격리도 (-50㏈ 미만) 삽입손실(-1.5㏈ 미만) 입력전력 허용치 (평균전력 0.5 watt 이상 ) 입출력 정재파비 (1.3:1) 등을 고려하여 설계하였으며, 제작은 인텍웨이브사의 알루미나 기판을 이용한 thin film 공정을 이용하였으며, 측정 또한 이 네 가지에 중점을 두었다. 격리도는 중심 주파수 근방에서 비교적 넓은 대역을 가지고 -50㏈ 미만이었으며, 삽입손실은 -1.3㏈-1.6㏈였다. 입출력 정재파비는 1 -1.4였다.

  • PDF

Sigmoid Colon Perforation by a Distal Ventriculoperitoneal Shunt Catheter (뇌실복강간단락술 원위 도관에 의한 구불결장의 천공)

  • Shin, Dong-Keun;Kim, Seong-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.171-174
    • /
    • 2008
  • We report an unusual case of a sigmoid colon perforation after ventriculoperitoneal shunt surgery. Distal catheters are known to cause perforation in the setting of colonoscopy. The exact pathogenesis of this complication is not clear, but it can cause serious complications. Hence, patients require prompt and aggressive management, including laparotomy with bowel wall repair, catheter removal, and antibiotic therapy.

  • PDF

Speed Characteristics of Direct Current Shunt Motors (직류 분권전동기의 속도 특성)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.69-72
    • /
    • 2012
  • It is well known that speed of a direct current shunt motor is inverse proportional to flux. This paper presents speed expression to show that speed is not inverse proportional to flux. The presented speed vs. flux curves are verified by experimental result that shows the need of the revision of speed vs. flux curves shown in conventional text books.

Study on the control coordination of STATCOM and Switched Shunt considering their dynamic characteristics in bulk power system (대규모 전력계통에서 STATCOM과 Switched Shunt의 동특성을 고려한 협조제어 검토)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Lee, J.H.;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.184-186
    • /
    • 2003
  • As STATCOM is considered to be installed in bulk power system, various studios are conducted to establish strategies for system operation considering STATCOM. This paper describes control strategy for coordinating STATCOM with existing switched shunt in bulk power system.

  • PDF

Analysis of two current feedback methods using shunt resistor (Shunt Resistor을 이용한 두 가지 전류 피드백 방법 분석)

  • Joo, Dong-Myoung;Jo, Won-Je;Shin, Seung-Min;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.318-319
    • /
    • 2010
  • 동기 전동기 구동에서는 정밀한 토크 제어를 위해 벡터 제어가 필요하다. 이를 위해 전류 피드백이 필요하며, 전류를 검출하는 방법으로 1개 또는 3개의 shunt resistor를 사용하여 각각 dc-link 전류 검출 또는 상 전류를 검출하는 것이 있다. 이 전류 검출 방법들의 문제 발생 구간을 분석한다.

  • PDF