• 제목/요약/키워드: Shoulder position

Search Result 431, Processing Time 0.025 seconds

Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion (측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구)

  • Lee, So-Joon;Hur, Young-Gu
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

The Effect of Thoracic Posture on The Shoulder Range of Motion and on Three-Dimensional Scapular Kinematics (흉추 자세가 견관절 가동범위와 3차원적 견갑골 운동학에 미치는 영향)

  • Park, Seung-Kyu;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.197-204
    • /
    • 2010
  • Scapular position and motion are essential for normal upper limb mobility; Further, the posture of patients with thoracic kyphosis is related to shoulder girdle function and disorder. The purpose of this study was to examine the effects of thoracic posture on the shoulder range of motion and on three-dimensional scapular kinematics. Thirty healthy subjects performed right-arm abduction along the frontal plane while standing in both erect and in slouched trunk posture. The scapular position and rotation, and shoulder and thoracic angles were recorded using a motion analysis system. The scapular upward rotation and internal rotation were significantly altered according to postural tatiges; however, scapular tilt was not affected. Shoulder angle was significantly decreased in the slouched posture as c rpared to tatt in the erect posture. Thus, a slouched posture(thoracic kyphosis) significantly affects the shoulder range of motion and scapular kinematics during shoulder abduction in the frontal plane.

Comparison on Grip Strength according to Shoulder Joint Angle with Elbow Extension (주관절신전 상태에서 견관절 각도에 따른 파악력 비교)

  • Seo, Gyu-Weon;Baek, Seung-Hwa;Shin, Hong-Cheul
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.915-921
    • /
    • 1999
  • The purpose of this study was to determine the effect of testing posture and shoulder position on grip strength. The subjects were one hundred volunteers of Shinsung College (50 males and 50 females), ages from 20 to 27 years(mean age of 22.1 years). This study was carried out from september 7 to setember 10, 1998. The data were analyzed by mean and deviation, unpaired t-test, paired t-test, one way ANOVA and correlation. These results were obtained as follows; 1. Comparison on grip strength by left and right hand, there was a significant difference in standing and sitting position (p<0.05). 2. Comparison on grip strength between male and female, there was a significant difference in standing and sitting position (p<0.05). 3. One-way ANOVA on grip strength according to shoulder joint angle, there was a no significant difference in standing and sitting position (p>0.05). 4. Correlation on grip strength by sitting verus standing, there was a very significantly difference (p<0.01).

  • PDF

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Effect of Shoulder Position on Scapular Muscle Activity during Scapular Protraction

  • Yun, Sung Joon;Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.3
    • /
    • pp.157-162
    • /
    • 2020
  • Purpose: This study was to evaluate several tasks performed at a high intensity in terms of their ability to elicit EMG activity in the serratus anterior by comparing the EMG activities of the serratus anterior, upper trapezius, and lower trapezius muscles during six tasks combined shoulder flexion with rotation. Methods: Fifteen healthy males were recruited to this study. Each subject was instructed to assume a sitting position without back support and asked to flex (90° or 120°) the right shoulder and protract the scapula in the sagittal plane with maximal external rotation; to assume a neutral position; or to internally rotate the glenohumeral joint. The EMG data were collected from the serratus anterior (SA), upper trapezius (UT), and lower trapezius (LT) muscles were normalized to maximum voluntary isometric contraction. The UT/LT and UT/SA muscle activity ratios in each task were assessed by calculating the surface EMG. Data were analyzed by two-way repeated-measures analysis of variance, with the level of significance set at p<0.05. Results: The results of this study, shoulder flexion with external rotation resulted in low upper trapezius/serratus anterior and upper trapezius/lower trapezius ratios and a relatively high level of serratus anterior activation. Conclusion: Shoulder flexion with external rotation used herein may be considered as important for clinical interventions aimed at selectively increasing SA strengthen and clinical selection of exercises for improving glenohumeral joint and scapulothoracic control.

Suggestion of Modified Y-View in Supine Position (Supine Position에서 Modified Y-View의 제안)

  • Shin, Seong-Gyu;Baek, Seong-Min;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This study was performed to design a modified Y-View as an imaging method for the Y-View in supine position for patients who requires Y-View imaging for the diagnosis of shoulder impingement syndrome but having trouble for the positioning of patients complaining of shoulder pain. On the result of comparative analysis of the images obtained by changing the lateral-medio degree of X-ray tube into $35^{\circ}$, $40^{\circ}$, and $45^{\circ}$ while patient is in supine position, $40^{\circ}$ of X-ray tube in lateral-medio direction produced the most valuable image for the diagnosis by best describing the shapes of acromion, clavicle space, and coracoacromial arch. Therefore, patients who have difficulty in Y-View position to obtain Y-View image, modified Y-View can be applied as a useful alternative method. By this study, various applications not only in shoulder impingement syndrome but also in diverse omarthralgia diseases are expected.

Arthroscopic rotator cuff surgery without traction system in the lateral position (측와위에서 견인 기구 없이 시행하는 견관절경하 회전근 개 수술)

  • Moon, Young-Lae;Jung, Heuk-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • Object: To evaluate the efficiencies of the arthroscopic rotator cuff surgery which is Performed without the traction system in the lateral decubitus position. Methods: Twenty-nine cases of the arthroscopic rotator cuff surgery performed without the traction system in the lateral decubitus position were studied from February, 2002 to January, 2005. We performed a repair using the arthroscopic debridement and the arthroscopic rotator cuff repair, or using the mini-open incision technique after the confirmation of rotator cuff tear, then, the arthroscopic subacromial decompression was performed after the confirmation of subacromial lesions Results: We could easily find the subscapularis tear which was often overlooked in the arthroscopic rotator cuff surgery performed with the traction surgery by the relaxation of the subscapularis, as the arm position was internally rotate about 45 to 70 degrees from abducted position. We found that the operation time was reduced 14 minutes shorter than the operation time of the controlled group which had the surgery with the traction system on the average. We also found that there were no neurovascular complications from all cases. Conclusions: The arthroscopic rotator cuff surgery without traction system in the lateral decubitus position provided the better visual field, easy manipulation of the joint and reducing operation time.

Characteristics of shoulder pain, muscle tone and isokinetic muscle function according to the scapular position of elite boxers

  • Lee, Ju-Hong;Kim, Ho;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.98-104
    • /
    • 2020
  • Objective: The shoulders are a particularly an important body part for elite boxers. The purpose of this study was to investigate the characteristics of the upper trapezius (UT), infraspinatus (IS) muscle tone, pain, and isokinetic muscle function of shoulder movements such as external rotation, internal rotation, protraction, and retraction according to the scapular position of elite boxers of the Korean national team. Design: Cross-sectional study. Methods: Using the double square method, the scapular position was measured and divided into the forward scapular position group (n=8) with a measurement distance of 135 mm or more, and the normal scapular position group (n=10) with a measurement distance of less than 135 mm. Through the numeric rating scale of the subject, the pain value displayed during movement was measured. The muscle tone of the subjects' UT and IS were measured. The isokinetic muscle function of ER, IR, protraction, and retraction were measured using isokinetic exercise equipment. Results: The results of this study showed statistically significant differences when comparing muscle tone of the UT and IS, shoulder pain, isokinetic function of ER and IR, protraction, and retraction according to scapular position (p<0.05). Conclusions: The findings of this study were that shoulder muscle tone, pain, and isokinetic muscle function were affected according to the scapular position of elite boxers. In the future, this information may be a useful indicator when studying the effects of medium and long-term intervention in elite boxers who possess these characteristics.

Comparison of Distance of Subacromial Space Using Ultrasonographic Measurement on Arm Positions of Shoulder Injured Patients (견부손상환자의 팔의 자세에 따른 초음파 영상을 이용한 견봉하공간 거리의 비교)

  • Jee, Eun-Mi;Kim, Suhn-Yeop;Park, Ji-Whan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.397-406
    • /
    • 2011
  • Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.