• 제목/요약/키워드: Shortening Effect

검색결과 408건 처리시간 0.029초

고추 과피의 천공률이 건조에 미치는 영향 (Effect of Opening Ratio of Red Pepper Surface on Drying)

  • 조용진
    • Journal of Biosystems Engineering
    • /
    • 제18권3호
    • /
    • pp.270-274
    • /
    • 1993
  • Many researches have been performed to shorten drying time and cost of red pepper in Korea. Nevertheless, an effective drying method for red pepper is not developed yet. This study was conducted to analyze the effect of opening ratio of red pepper's surface on drying for development of an effective drying method. The drying method with punching treatment is expected to be effectively utilized for shortening drying time and improving quality of red pepper.

  • PDF

Anticolitic Effect of the Rhizome Mixture of Anemarrhena asphodeloides and Coptidis chinensis (AC-mix) in Mice

  • Jang, Se-Eun;Jeong, Jin-Ju;Hyam, Supriya R.;Han, Myung Joo;Kim, Dong-Hyun
    • Biomolecules & Therapeutics
    • /
    • 제21권5호
    • /
    • pp.398-404
    • /
    • 2013
  • During a screening program to search the anticolitic herbal medicines, 80% ethanol extract of the rhizome of Anemarrhena asphodeloides (AA) was found to potently inhibit the expression of proinflammatory cytokines TNF-${\alpha}$ and IL-1${\beta}$, as well as the activation of NF-${\kappa}B$ in LPS-stimulated colonic macrophages, followed by that of the rhizome of C. chinensis (CC). AA also potently inhibited TNBS-induced colitic markers, shortening of the colon and increase of macroscopic score, myeloperoxidase activity, TNF-${\alpha}$, IL-1${\beta}$, and IL-6, in mice. The synergistic effect of CC against the anticolitic effect of AA was investigated. CC synergistically inhibited the anticolitic effect of AA. AC-mix (AA+CC, 1:1) potently inhibited them. AC-mix also inhibited the activation of NF-${\kappa}B$, as well as the expression of TNF-${\alpha}$, IL-1${\beta}$, IL-6, iNOS and COX-2. The effects of AC-mix against oxazolone-induced colitis were investigated in mice. AC-mix also potently inhibited oxazolone-induced inflammatory markers, colon shortening, macroscopic score, myeloperoxidase activity, NF-${\kappa}B$ activation and proinflammatory cytokines. Overall, the anti-colitic effect of AC-mix was superior to that of mesalazine. Based on these findings, AC-mix may improve colitis by inhibiting NF-${\kappa}B$ activation.

단체급식에서의 센트럴 키친 제품 이용 실태 조사 (A Survey on the Using Practice of the Central Kitchen Products in the Catering)

  • 송지영;심기현
    • 한국식품조리과학회지
    • /
    • 제29권4호
    • /
    • pp.425-437
    • /
    • 2013
  • This study conducted a questionnaire survey of the current use status of central kitchen products on 198 dietitians and cooks working at a catering center of a company affiliated with group S in order to investigate the use state of the central kitchen products in catering. The largest groups of respondents answered that they use the central kitchen products once two to four days. As a reason to use it, the largest group answered that they used it because of the ease of preparation. In addition, the results show that the subjects often use sauce and processed vegetables among the central kitchen products. This study investigated the efficiency of cooking, hygiene and safety management of the central kitchen products. The results show that they have a large effect on shortening the cooking time. The quality control and service efficiency of the central kitchen products showed a positive reaction to the menu diversification and excellent quality but a negative reaction to the nutritious superiority. The operating cost efficiency of the central kitchen products generally showed a negative reaction except for the reducing effect of waste rate. As an improvement of the central kitchen products, the survey shows that the reduction in price and quality progress should be most urgently improved. Based on these results, the introduction of the central kitchen products into to the catering enables to standardize mass production, improve the taste and quality, cook without professional chefs and produce productivity increasing effect in the catering by the time shortening effect.

의료서비스의 대기시간 요인이 고객만족과 서비스 가치에 미치는 영향 (A Study on the Effect of Waiting Time factor of Hospitals on Customer Satisfaction and Service Values)

  • 김일권;권창익;양종현;장동민
    • 한국병원경영학회지
    • /
    • 제15권3호
    • /
    • pp.47-68
    • /
    • 2010
  • One of the important complaint factors by the patients using medical institutions is various kinds of waiting time. This research is about the causal relationships among waiting time(application of waiting time, perceived of waiting time, fairness of waiting, explanation of the delay, acceptance possibility), service values, and customer satisfaction. The subjects for this study were 256 out-patients currently using seven general hospitals in the Busan area. The findings of the empirical analysis are as follows: First, the good application of waiting time or fair waiting time procedure didn't actually affect perceived waiting time. Second, though the application of waiting time didn't affect acceptance possibility, the fair procedure of waiting time had an affirmative effect on acceptance possibility. Third, even when there was enough explanation about the need to wait, it could shorten perceived waiting time but failed to get sufficient sympathy or agreement from the patients. Fourth, the possibility of acceptance following the sufficient sympathy of patients had an effect on shortening perceived waiting time. Fifth, perceived waiting time lowered customer satisfaction, but had no negative effect on service values. Finally, the ranges of acceptance possibility by the patients were found to increase customer satisfaction and maximize service values. In conclusion, every medical institution needs to focus on, first of all, shortening waiting time for more customer satisfaction and improved service values.

  • PDF

골프 비거리 증가를 위한 기능성 보조 웨어의 효과 검증 (Effect Verification of Wearable Assisting Wear for Increasing Golf Carry Distance)

  • 박양선;우병훈;임영태
    • 한국운동역학회지
    • /
    • 제22권4호
    • /
    • pp.421-428
    • /
    • 2012
  • The purpose of this study was to verify the effects of developed assisting wear which maximize trunk(back) muscle's stretch-shortening effect during backswing and downswing for increasing golf ball carrying distance. Design and fabrication of assistive wear were performed based on the results of analyzed data of trunk EMG activity from the golf drive swings of elite professional male golfers during back swing and downswing phases. After the prototype of wear was produced, surface EMG and Flight scope tests were conducted to verify the effectiveness of the wear for increasing distance to the professional golfers. Results indicated that wearing trial showed significant longer carry distance than the non-wearing trial(p<.001). The carry distance of wearing trial showed an average 229 m compared to the non-wearing trial, the average 225 m. The swing with wearing also produced significantly faster ball speed than the trial without wearing(p<.05). Average 245 Km/h and 244 Km/h were produced for the swing with and without wearing trails, respectively. EMG results also indicated that the muscle activity of left psoas was significantly increased for wearing trial during downswing and near the impact. Thus, this may affect positively to increase club head speed. The activity of the left latissimus dorsi was dramatically increased during the final stage of swing. This generates elongation effect for longer follow-through and increased impulse between club and ball so eventually valid assistance to increase carry distance. Therefore, the developed assisting wear was proved to be effective tool for increasing golf ball carry distance with maximizing trunk(back) muscle's stretch-shortening effect during backswing and downswing.

PNF 수축-이완 기법, 근막이완기법, 마사지건이 넙다리뒤근 단축 대상자의 유연성 및 압통에 미치는 영향 (Effects of PNF Contract-Relax Technique, Myofascial Release, and Massage Guns on Hamstring Flexibility and Pressure Pain Threshold in Subjects with Hamstring Shortening)

  • 정소영;황호성;이다은;박두진
    • PNF and Movement
    • /
    • 제21권1호
    • /
    • pp.63-74
    • /
    • 2023
  • Purpose: This study aims to compare hamstring flexibility and pressure pain threshold (PPT) after an intervention with proprioceptive neuromuscular facilitation contract-relax (PNF CR) technique, myofascial release (MFR), and a massage gun (MG), as well as to verify the effectiveness of the MG. Methods: This study recruited 36 participants (22 males and 14 females) with shortening of less than 70 degrees upon a straight leg raise (SLR) test, and they were randomly assigned to one of the PNF, MG, and MFR groups, each of which underwent its own protocol for 30 minutes. Flexibility of the hamstring was measured after the intervention using the active and passive knee extension (AKE and PKE) test, the sit and reach test, and PPT. Results: The AKE and PKE angles significantly decreased, as well as significantly increased in flexibility when each of the PNF, MFR, and MG interventions was performed (p<0.05). In addition, there was no significant difference among groups. However, according to the Cohen's D effect size, the MG demonstrated the largest effect size in AKE (d = 1.41) and PNF demonstrated the largest effect size in PKE (d = 1.66) and flexibility (d = 0.63). Conclusion: All interventions used in our study are effective in increasing hamstring flexibility. Based on the Cohen's D effect size, an MG is beneficial to increase the AKE, whereas PNF CR technique is recommended for increasing PKE and flexibility.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Waxy Maize Starch의 대체율을 달리하여 제조한 옐로우 레이어 케이크의 특성 (The Properties of Yellow Layer Cakes Made by Different Substituting Levels of Waxy Maize Starch for Shortening)

  • 송은승;강명화
    • 동아시아식생활학회지
    • /
    • 제14권1호
    • /
    • pp.39-46
    • /
    • 2004
  • 본 연구에서는 옐로우 레이어 케이크의 재료 중 쇼트닝 대신 시판 탄수화물계 지방대체물인 waxy maize starch의 사용 가능성을 측정하고, 저 열량 레이어 케이크를 제조하기 위한 최적 비율을 결정하기 위해 여러 가지 비율로 대체하여 제조한 케이크의 물리적 및 관능적 특성을 평가하였다. 지방대체율이 증가할수록 케이크의 비중은 증가하지만 점도는 감소하였다. 주사전자 현미경 측정 결과, 지방 대체물이 증가함에 따라 air cell과 함께 지방구의 수와 크기는 감소하였고, 점도가 높을수록 치밀한 구조를 보였다. 또한, 물성특성 측정결과 대체율이 증가할수록 hardness, springiness, cohe-ssiveness, gumminess, chewiness 및 resilience는 감소하였다. 관능적 평가에서 색의 경우에만 waxy maize starch 대체 45%에서 가장 우수한 것으로 평가되었고 지방 대체율이 크게 증가했을 때 전반적인 관능적 평가에서 좋지 않은 것으로 나타났다. 따라서 지방 대체물인 waxy maize starch는 저 열량 레이어 케이크 제조 시 적은 비율의 쇼트닝 대체로 사용한다면, 새로운 저 열량 레이어 케이크 제조를 위한 새로운 소재로 사용 가능성이 시사되었다.

  • PDF

근위 중족골 절골술과 변형 chevron 절골술을 이용한 무지 외반증의 수술적 치료의 비교 (A Comparison of Operative Treatment of Hallux Valgus with a Proximal Metatarsal Osteotomy and with a Modified Chevron Osteotomy)

  • 최재열;신헌규;김영훈;김홍균;이호진
    • 대한족부족관절학회지
    • /
    • 제8권1호
    • /
    • pp.64-70
    • /
    • 2004
  • Purpose: We compared the result of a proximal metatarsal closed wedge osteotomy and soft tissue procedure with a modified chevron osteotomy and soft tissue procedure in the treatment of hallux valgus. Materials and Methods: Between March 1999 and February 2003, we performed proximal metatarsal closed wedge osteotomy and soft tissue procedure on 17 feet (12 patients), and modified chevron osteotomy and soft tissue procedure on 12 feet (9 patients). Results: According to Mayo clinic forefoot scoring system (FFSS), group 1, with proximal metatarsal closed wedge osteotomy, shows 67.2 points postoperatively and group 2, with modified chevron osteotomy, shows 68.5 points postoperatively. In group 1, the average correction of hallux valgus angle and intermetatarsal angle was 20.8 degrees and 4.8 degrees, respectively. In group 2, the average correction of hallux valgus angle and intermetatarsal angle was 19.9 degrees and 4.7 degrees, respectively. The average shortening was 3.15 mm in group 1 and 1.38 mm in group 2. Conclusion: We obtained relatively good clinical and radiographic result in this study. The effect on shortening of the first metatarsal was greater in the proximal metatarsal closed wedge osteotomy than modified chevron osteotomy, but the metatarsal shortening did not related with metatarsalgia. So, both techniques seems optimal surgical treatment for hallux valgus deformity.

  • PDF

Pressure loading, end- shortening and through- thickness shearing effects on geometrically nonlinear response of composite laminated plates using higher order finite strip method

  • Sherafat, Mohammad H.;Ghannadpour, Seyyed Amir M.;Ovesy, Hamid R.
    • Structural Engineering and Mechanics
    • /
    • 제45권5호
    • /
    • pp.677-691
    • /
    • 2013
  • A semi-analytical finite strip method is developed for analyzing the post-buckling behavior of rectangular composite laminated plates of arbitrary lay-up subjected to progressive end-shortening in their plane and to normal pressure loading. In this method, all the displacements are postulated by the appropriate harmonic shape functions in the longitudinal direction and polynomial interpolation functions in the transverse direction. Thin or thick plates are assumed and correspondingly the Classical Plate Theory (CPT) or Higher Order Plate Theory (HOPT) is applied. The in-plane transverse deflection is allowed at the loaded ends of the plate, whilst the same deflection at the unloaded edges is either allowed to occur or completely restrained. Geometric non-linearity is introduced in the strain-displacement equations in the manner of the von-Karman assumptions. The formulations of the finite strip methods are based on the concept of the principle of the minimum potential energy. The Newton-Raphson method is used to solve the non-linear equilibrium equations. A number of applications involving isotropic plates, symmetric and unsymmetric cross-ply laminates are described to investigate the through-thickness shearing effects as well as the effect of pressure loading, end-shortening and boundary conditions. The study of the results has revealed that the response of the composite laminated plates is particularly influenced by the application of the Higher Order Plate Theory (HOPT) and normal pressure loading. In the relatively thick plates, the HOPT results have more accuracy than CPT.