• 제목/요약/키워드: Short-term Noise

검색결과 94건 처리시간 0.027초

Reliability of OperaVOXTM against Multi-Dimensional Voice Program to Assess Voice Quality before and after Laryngeal Microsurgery in Patient with Vocal Polyp (성대 용종 환자의 후두미세수술 전후 음성 평가에서 OperaVOXTM와 Multi-Dimensional Voice Program 간의 신뢰도 연구)

  • Kim, Sun Woo;Kim, So Yean;Cho, Jae Kyung;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • 제31권2호
    • /
    • pp.71-77
    • /
    • 2020
  • Background and Objectives OperaVOXTM (Oxford Wave Research Ltd.) is a portable voice analysis software package designed for use with iOS devices. As a relatively cheap, portable and easily accessible form of acoustic analysis, OperaVOXTM may be more clinically useful than laboratory-based software in many situations. The aim of this study was to evaluate the agreement between OperaVOXTM and Multi-Dimensional Voice Program (MDVP; Computerized Speech Lab) to assess voice quality before and after laryngeal microsurgery in patient with vocal polyp. Materials and Method Twenty patients who had undergone laryngeal microsurgery for vocal polyp were enrolled in this study. Preoperative and postoperative voices were assessed by acoustic analysis using MDVP and OperaVOXTM. A five-seconds recording of vowel /a/ was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). Results Several acoustic parameters of MDVP and OperaVOXTM related to short-term variability showed significant improvement. While pre-operative value of F0, jitter, shimmer, NHR was 155.75 Hz (male: 125.37 Hz, female: 183.37 Hz), 2.20%, 6.28%, 0.16, post-operative values of these parameter was 164.34 Hz (male: 129.42 Hz, female: 199.26 Hz), 2.15%, 5.18%, 0.14 Hz in MDVP. While pre-operative value of F0, jitter, shimmer, NHR was 168.26 Hz (male: 135.16 Hz, female: 201.37 Hz), 2.27%, 6.95%, 0.26, post-operative values of these parameters was 162.72 Hz (male: 128.267 Hz, female: 197.18 Hz), 1.71%, 5.36%, 0.20 in OperaVOXTM. There was high intersoftware agreement for F0, jitter, shimmer with intraclass correlation coefficient. Conclusion Our results showed that the short-term variability of acoustic parameters in both MDVP and OperaVOXTM were useful for the objective assessment of voice quality in patients who received laryngeal microsurgery. OperaVOXTM is comparable to MDVP and has high intersoftware reliability with MDVP in measuring the F0, jitter, and shimmer

Effects of Voice Therapy Using Gliding and Humming in Dysphonic Patients With Glottal Gap (활창과 허밍을 이용한 음성치료가 성문틈 환자의 음성 개선에 미치는 효과)

  • Jung, Dae-Yong;Shim, Mi-Ran;Hwang, Yeon-Shin;Kim, Geun-Jeon;Sun, Dong-Il
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • 제32권2호
    • /
    • pp.81-86
    • /
    • 2021
  • Background and Objectives Therapies have been reported to treat the glottal gap previously. However, these voice therapies showed the limits because many techniques focused only on one among breathing, resonance and phonation. In addition patients often have difficulties visiting hospital frequently. 'Gliding and humming' is vocal training technique that readjusts total vocal patterns such as breathing, resonance and phonation. This technique can be easily applied during short term sessions. The purpose of this study is to evaluate the efficiency of voice therapy with 'gliding and humming' for patients with glottic gap during short-term treatment sessions. Materials and Method Twenty-three patients with glottal gap were selected. Of all patients, 14 patients had sulcus vocalis and 12 patients had muscle tension dysphonia (MTD). Voice therapies were performed 1.9 sessions in average. GRBAS, jitter, shimmer, noise to harmonic ratio, semitone range, closed quotient_vowel and maximum phonation time were compared before and after the therapies. In addition, changes of glottal gap and MTD severity were evaluated. Results Statistically significant improvement was observed. MTD improvement was observed only among the patients with glottal gap improvement. Also sulcus vocalis group showed the statistically significant improvement. Conclusion 'Gliding and humming' was effective to the patients with glottic gap and sulcus vocalis. Also, among patients who have both glottic gap and MTD, the data suggests that voice therapy for glottic gap also makes improvement in MTD.

Deep Learning-Based Short-Term Time Series Forecasting Modeling for Palm Oil Price Prediction (팜유 가격 예측을 위한 딥러닝 기반 단기 시계열 예측 모델링)

  • Sungho Bae;Myungsun Kim;Woo-Hyuk Jung;Jihwan Woo
    • Information Systems Review
    • /
    • 제26권2호
    • /
    • pp.45-57
    • /
    • 2024
  • This study develops a deep learning-based methodology for predicting Crude Palm Oil (CPO) prices. Palm oil is an essential resource across various industries due to its yield and economic efficiency, leading to increased industrial interest in its price volatility. While numerous studies have been conducted on palm oil price prediction, most rely on time series forecasting, which has inherent accuracy limitations. To address the main limitation of traditional methods-the absence of stationarity-this research introduces a novel model that uses the ratio of future prices to current prices as the dependent variable. This approach, inspired by return modeling in stock price predictions, demonstrates superior performance over simple price prediction. Additionally, the methodology incorporates the consideration of lag values of independent variables, a critical factor in multivariate time series forecasting, to eliminate unnecessary noise and enhance the stability of the prediction model. This research not only significantly improves the accuracy of palm oil price prediction but also offers an applicable approach for other economic forecasting issues where time series data is crucial, providing substantial value to the industry.

Integrating GPS/INS/PL for Robust Positioning: The Challenging Issues

  • Wang, Jinling;Babu, Ravindra;Li, Di;Chan, Franics;Choi, Jin-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.127-132
    • /
    • 2006
  • The Global Positioning System (GPS), Inertial Navigation System (INS) and Pseudolite (PL) technologies all play very important roles in navigation systems. As an independent navigation system, GPS can provide high precision positioning results which are independent of time. However, the performance will become unreliable when the system experiences high dynamics, or when the receiver is exposed to jamming or RF interference. In comparison to GPS, though INS is autonomous and provides good short-term accuracy, its use as a standalone navigation system is limited due to the time-dependent growth of the inertial sensor errors. PLs are ground-based transmitters that can transmit GPS-like signals. They have some advantages in that their positions can be determined precisely, and the Signal-to-Noise Ratios (SNR) are relatively high. Because their combined performance, in principle, overcomes the shortcomings of the individual systems, the integration of GPS, INS and PL is increasingly receiving attention from researchers. Depending on the desired performance vs complexity, system integration can be carried out at different levels, namely loose, tight and ultra-tight coupling. Compared with loose and tight integration, although it is more complex in terms of system design, ultra-tight integration will be the basis of the next generation of reliable and robust navigation systems. Its main advantages include improved performance under exposure to high dynamics, and jamming and RF interference mitigation. This paper presents an overview of the ultra-tight integration developments and discusses some of the challenging issues.

  • PDF

LSTM based sequence-to-sequence Model for Korean Automatic Word-spacing (LSTM 기반의 sequence-to-sequence 모델을 이용한 한글 자동 띄어쓰기)

  • Lee, Tae Seok;Kang, Seung Shik
    • Smart Media Journal
    • /
    • 제7권4호
    • /
    • pp.17-23
    • /
    • 2018
  • We proposed a LSTM-based RNN model that can effectively perform the automatic spacing characteristics. For those long or noisy sentences which are known to be difficult to handle within Neural Network Learning, we defined a proper input data format and decoding data format, and added dropout, bidirectional multi-layer LSTM, layer normalization, and attention mechanism to improve the performance. Despite of the fact that Sejong corpus contains some spacing errors, a noise-robust learning model developed in this study with no overfitting through a dropout method helped training and returned meaningful results of Korean word spacing and its patterns. The experimental results showed that the performance of LSTM sequence-to-sequence model is 0.94 in F1-measure, which is better than the rule-based deep-learning method of GRU-CRF.

Feature Extraction based on Auto Regressive Modeling and an Premature Contraction Arrhythmia Classification using Support Vector Machine (Auto Regressive모델링 기반의 특징점 추출과 Support Vector Machine을 통한 조기수축 부정맥 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong;Kim, Joo-man;Kim, Seon-jong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제23권2호
    • /
    • pp.117-126
    • /
    • 2019
  • Legacy study for detecting arrhythmia have mostly used nonlinear method to increase classification accuracy. Most methods are complex to process and manipulate data and have difficulties in classifying various arrhythmias. Therefore it is necessary to classify various arrhythmia based on short-term data. In this study, we propose a feature extraction based on auto regressive modeling and an premature contraction arrhythmia classification method using SVM., For this purpose, the R-wave is detected in the ECG signal from which noise has been removed, QRS and RR interval segment is modelled. Also, we classified Normal, PVC, PAC through SVM in realtime by extracting four optimal segment length and AR order. The detection and classification rate of R wave and PVC is evaluated through MIT-BIH arrhythmia database. The performance results indicate the average of 99.77% in R wave detection and 99.23%, 97.28%, 96.62% in Normal, PVC, PAC classification.

The Affecting for Awareness of Exposure at Hazardous Materials on the Working Satisfaction of Female Workers in the Small Scale Industry (중소규모 산업장 여성근로자들의 작업환경에 대한 인식이 직무만족에 미치는 영향)

  • Han, Seung-Hyun;Lee, Myung-Kun;Ahn, Kyung-Hyuk;Lee, Jung-Hwa
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제6권2호
    • /
    • pp.281-291
    • /
    • 1996
  • 458 female workers working in the small and medium scaled industries in Inchon area were surveyed to study their general characteristics, health behavior, working and environmental conditions, awareness of exposure at hazardous materials, current health status, and degree of working satisfaction. Self-administered questionnaire was distributed to the female workers with the explanation by trained interviewer on the purpose of survey and the method how to answer. The results were as follows : (1) 75.5% of the respondents are living with their families and others are living in domitary or rent house for herself. Age distribution ranges from teenagers to warren in their forties. In marital status 69.0% of workers are single and 31.0% of them have ever married. 69.4% of workers are high school graduate. The size of factory is 48.3% with less than 300 workers, 42.1% with 300~500 workers. (2) Most of the workers(86.7%) are full time workers, 52% of the respondents have working experiences in other factories. More than 65% have fewer than 5 years working experience. (3) The awareness of exposure at noise was 33% of respondents, it was significantly different by skilled status. The awareness of exposure at dust, other hazardous material was each 13.3%, 12.4% of respondents. (4) 26% of them are unsatisfied with their working cognitions and 43.7% of them are unsatisfied with their welfare in occupational system unsatisfactory rate of promotion is higher in the unmarried workers(45.6%), skilled workers(47.2%), full time workers(47.4%), long term workers(50%), and awareness group of exposure hazardous material(51.3%), compared to married women workers, unskilled workers, part-time workers, short term workers and unawareness group of exposure at hazardous materials. (5) The index of working satisfaction is rated on a scale of 1 to 10 with the higher point indicating higher satisfaction. Among the selected variables, marital status, working status, the awareness of exposure at hazardous materials, were statistically significant with the index of working satisfaction. (6) By multiple regression analysis showed that the determinant factors of index of working condition were health index, the awareness of exposure at dust, the awareness of exposure other hazardous materials, marital status and working period. In conclusion, there is a significant relationship between the awareness of exposure at hazardous material the index of working satisfaction. Therefore if the workers are less exposed to the hazardous material and are educated properly they will be more satisfied with their work thus improving their health and productivity. Finally, with the result of this study, there is a great need for the development of a health promotion program and a welfare policy for small-scale factories.

  • PDF

Avoidance of Internal Resonances in Hemispherical Resonator Assemblies from Fused Quartz Connected by Indium Solder

  • Sarapuloff, Sergii A.;Rhee, Huinam;Park, Sang-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.835-841
    • /
    • 2013
  • Modern solid-state gyroscopes (HRG) with hemispherical resonators from high-purity quartz glass and special surface superfinishing and ultrathin gold coating become the best instruments for precise-grade inertial reference units (IRU) targeting long-term space missions. Designing of these sensors could be a notable contribution into development of Korea as a space nation. In participial, 40mm diameter thin-shell resonator from high-purity fused quartz, fabricated as a single-piece with its supporting stem has been designed, machined, etched, tuned, tested, and delivered by STM Co. (ATS of Ukraine) several years ago; an extremely-high Q-factor (upto 10~20 millions) has been shown. Understanding of the best way how to match such a unique sensor with inner glass assembly of the gyro means how to use the high potential in a maximal extent; and this has become the urgent task. Inner quartz glass assembly has a very thin indium (In) layer soldered the resonator and its silica base (case), but effects of internal resonances between operational modal pair of the shell-cup and its side (parasitic) modes can notable degrade the potential of the sensor as a whole, instead of so low level of resonator's intrinsic losses. Unfortunately, there are special combinations of dimensions of the parts (so-called, "resonant sizes"), when intensive losses of energy occurs. The authors proposed to use the length of stem's fixture as an additional design parameter to avoid such cases. So-called, a cyclic scheme of finite element method (FEM) and ANSYS software were employed to estimate different combinations of gyro assembly parameters. This variant has no mismatches of numerical origin due to FEM's discrete mesh. The optimum length and dangerous "resonant lengths" have been found. The special attention has been paid to analyses of 3D effects in a cup-stem transient zone, including determination of a difference between the positions of geometrical Pole of the resonant hemisphere and of its "dynamical Pole", i.e., its real zone of oscillation node. Boundary effects between the shell (cup) and 3D short "beams" (inner and outer stems) have been ranged. The results of the numerical experiments have been compared with the classic model of a quasi-hemispherical shell band with inextensional midsurface, and the solution using Rayleigh's functions of the $1^{st}$ and $2^{nd}$ kinds. To guarantee the truth of the recommended sizes to a designer of the real device, the analytical and FEM results have been compared with experimental data for a party of real resonators. The consistency of the results obtained by different means has been shown with errors less than 5%. The results notably differ from the data published earlier by different researchers.

  • PDF

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • 제28권5호
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • 제25권3호
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.